Page 161

ND-45857 (E) CHAPTER 4
Addendum-001 Page 137
AUGUST, 1998 Revision 3.1
SYSTEM DATA PROGRAMMING
DESCRIPTION DATA
Area Code + Local Office Code • YY=05
00 > 214555
Last 4 digits of telephone no. + 4 digit SPID • YY=30
040 > 62040101
041 > 62050101
050 > 62060101
051 > 62070101
Set as ISDN trunk route.
Answer signal arrives.
Incoming connection signaling.
Hooking signal sending to outside not 
provided.
Enable digit conversion.
Disable trunk queuing outgoing.
Assign as BRI trunk route.•
•
•
•
•
•
•YY=00
10...

Page 162

CHAPTER 4 ND-45857 (E)
Page 138 Addendum-001
Revision 3.1 AUGUST, 1998
SYSTEM DATA PROGRAMMING
BRI Trunks in PBX A are:
Circuit 1: B1  (214) 555-6868
B2   (214) 555-6869
Circuit 2: B1  (214) 555-6870
B2  (214) 555-6871
Note:You must have this information prior to programming E-CCIS.
• Home-Side Trunk Programming
DESCRIPTION DATA
Assign Home-Side trunks to even numbered 
addresses.• YY=05
3200 > D030
3202 > D031
3204 > D032
3206 > D033
Assign trunks to trunk routes. • YY=00
030 > 30
031 > 30
032 > 30
033...

Page 163

ND-45857 (E) CHAPTER 4
Addendum-001 Page 139
AUGUST, 1998 Revision 3.1
SYSTEM DATA PROGRAMMING
DESCRIPTION DATA
Assign CCH Channel No.
Assign as E-CCIS route.•
•YY=91
30 > 0
31 > 0
YYY=135
30 > 0
31 > 0
Assign CIC no. • YY=35
030 > 001
031 > 002
032 > 003CM35
CM30
A
END 

Page 164

CHAPTER 4 ND-45857 (E)
Page 140 Addendum-001
Revision 3.1 AUGUST, 1998
SYSTEM DATA PROGRAMMING
• Mate-Side Trunk Programming
DESCRIPTION DATA
Assign Mate-Side trunks to odd numbered 
addresses.• YY=05
3201 > D040
3203 > D041
3205 > D042
3207 > D043
Assign trunks to trunk routes.
Assign last 4 digits of telephone number in 
PBX A.•
•YY=00
040 > 40
041 > 41
042 > 42
043 > 43
YY=19 
040 > 6868
041 > 6869
042 > 6870
043 > 6871
Assign as Tie Line routes.
Assign abbreviated codes to terminate call to 
PBX A....

Page 165

ND-45857 (E) CHAPTER 4
Addendum-001 Page 141
AUGUST, 1998 Revision 3.1
SYSTEM DATA PROGRAMMING
3.10.2 Program Termination for Incoming E-CCIS Calls
3.10.3 Program Access Code/Terminating Number Assignment for Outgoing E-CCIS Calls
3.10.4 Program Release Timer for Virtual Tie Lines (Home-Side & Mate-Side Trunks)DESCRIPTION DATA
Convert received digits to Mate-Side trunks. • Y=0 & Y=1
6204 > B040
6205 > B041
6206 > B042
6207 > B043
DESCRIPTION DATA
Allocate memory to store the terminating num-
bers of PBX...

Page 166

CHAPTER 4 ND-45857 (E)
Page 142 Addendum-001
Revision 3.1 AUGUST, 1998
SYSTEM DATA PROGRAMMING
3.10.5 CCH Data Assignment:
Sense Wheel for PN-SC00 is set to 06.
Originating Point Code for PBX  B is 00002.
3.10.6 Alternative ISDN Route Assignment
To provide an ISDN line as an alternative route when the call can not be connected through the virtual tie line,
do the programming for Least Cost Routing. Refer to the NEAX2000 IVS Feature Programming Manual.
For the call through the alternative ISDN route, the...

Page 167

ND -4 5857 ( E)  CHAPTER 5
CHAPTER 5  INSTA LLA TIO N T E S T 

Page 168

CHAPTER 5 ND-45857 (E)
Pag e 1 44
Revision 3.0
INSTALLATION TEST
Table 5-1  Alarm Indications on the PN-24DTA Card
LEDLED INDICATION FAULT
NORMAL FAULT CAUSE ACTION
RUNFlash 
(120IPM)OffDTI Trunk data is not 
correctly assigned.1.Reset the MB switch.
(Down®UP®Down)
2.Confirm the program data 
(CM05, CM07 YY = 01)
CRC Off OnBit Error Rate exceeds the 
predetermined value.Check the transmission line and external 
equipment.
PCM Off OnNo PCM signals arrive from 
the distant office.1.Check to see if the DTI...

Page 169

ND-45857 (E) CHAPTER 5
Page 145
Revision 3.0
INSTALLATION TEST
3.2 PLO Operation Test
The following tests should be performed to confirm the PLO operation’s normality.
• Clock Signal Generation Test
• Clock Signal Synchronization Test To be performed when the PBX is a slave office.
• Interoffice Synchronization Test
3.2.1 Clock Signal Generation Test
This test checks to see if the PLO keeps generating clock signals at the frequency of the previous master clock,
when the external clock signal from the...

Page 170

CHAPTER 5 ND-45857 (E)
Pag e 1 46
Revision 3.0
INSTALLATION TEST
3.2.2 Clock Signal Synchronization Test
This test checks to see if the PLO keeps synchronizing with the external clock signals, when the external clock
signals from the master/sub-master office has input again after it has stopped once.
To perform this test, an “In Service” transmission line is required.
(1) When providing one clock supply route (from a master office)
STEP 1: On the DTI card extracting clock signals (DTI0), set the SW-1 and...
Start reading NEC Neax2000 Ivs Isdn System Manual