NEC Neax2000 Ivs Isdn System Manual
Here you can view all the pages of manual NEC Neax2000 Ivs Isdn System Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 161
ND-45857 (E) CHAPTER 4 Addendum-001 Page 137 AUGUST, 1998 Revision 3.1 SYSTEM DATA PROGRAMMING DESCRIPTION DATA Area Code + Local Office Code • YY=05 00 > 214555 Last 4 digits of telephone no. + 4 digit SPID • YY=30 040 > 62040101 041 > 62050101 050 > 62060101 051 > 62070101 Set as ISDN trunk route. Answer signal arrives. Incoming connection signaling. Hooking signal sending to outside not provided. Enable digit conversion. Disable trunk queuing outgoing. Assign as BRI trunk route.• • • • • • •YY=00 10...
Page 162
CHAPTER 4 ND-45857 (E) Page 138 Addendum-001 Revision 3.1 AUGUST, 1998 SYSTEM DATA PROGRAMMING BRI Trunks in PBX A are: Circuit 1: B1 (214) 555-6868 B2 (214) 555-6869 Circuit 2: B1 (214) 555-6870 B2 (214) 555-6871 Note:You must have this information prior to programming E-CCIS. • Home-Side Trunk Programming DESCRIPTION DATA Assign Home-Side trunks to even numbered addresses.• YY=05 3200 > D030 3202 > D031 3204 > D032 3206 > D033 Assign trunks to trunk routes. • YY=00 030 > 30 031 > 30 032 > 30 033...
Page 163
ND-45857 (E) CHAPTER 4 Addendum-001 Page 139 AUGUST, 1998 Revision 3.1 SYSTEM DATA PROGRAMMING DESCRIPTION DATA Assign CCH Channel No. Assign as E-CCIS route.• •YY=91 30 > 0 31 > 0 YYY=135 30 > 0 31 > 0 Assign CIC no. • YY=35 030 > 001 031 > 002 032 > 003CM35 CM30 A END
Page 164
CHAPTER 4 ND-45857 (E) Page 140 Addendum-001 Revision 3.1 AUGUST, 1998 SYSTEM DATA PROGRAMMING • Mate-Side Trunk Programming DESCRIPTION DATA Assign Mate-Side trunks to odd numbered addresses.• YY=05 3201 > D040 3203 > D041 3205 > D042 3207 > D043 Assign trunks to trunk routes. Assign last 4 digits of telephone number in PBX A.• •YY=00 040 > 40 041 > 41 042 > 42 043 > 43 YY=19 040 > 6868 041 > 6869 042 > 6870 043 > 6871 Assign as Tie Line routes. Assign abbreviated codes to terminate call to PBX A....
Page 165
ND-45857 (E) CHAPTER 4 Addendum-001 Page 141 AUGUST, 1998 Revision 3.1 SYSTEM DATA PROGRAMMING 3.10.2 Program Termination for Incoming E-CCIS Calls 3.10.3 Program Access Code/Terminating Number Assignment for Outgoing E-CCIS Calls 3.10.4 Program Release Timer for Virtual Tie Lines (Home-Side & Mate-Side Trunks)DESCRIPTION DATA Convert received digits to Mate-Side trunks. • Y=0 & Y=1 6204 > B040 6205 > B041 6206 > B042 6207 > B043 DESCRIPTION DATA Allocate memory to store the terminating num- bers of PBX...
Page 166
CHAPTER 4 ND-45857 (E) Page 142 Addendum-001 Revision 3.1 AUGUST, 1998 SYSTEM DATA PROGRAMMING 3.10.5 CCH Data Assignment: Sense Wheel for PN-SC00 is set to 06. Originating Point Code for PBX B is 00002. 3.10.6 Alternative ISDN Route Assignment To provide an ISDN line as an alternative route when the call can not be connected through the virtual tie line, do the programming for Least Cost Routing. Refer to the NEAX2000 IVS Feature Programming Manual. For the call through the alternative ISDN route, the...
Page 168
CHAPTER 5 ND-45857 (E) Pag e 1 44 Revision 3.0 INSTALLATION TEST Table 5-1 Alarm Indications on the PN-24DTA Card LEDLED INDICATION FAULT NORMAL FAULT CAUSE ACTION RUNFlash (120IPM)OffDTI Trunk data is not correctly assigned.1.Reset the MB switch. (Down®UP®Down) 2.Confirm the program data (CM05, CM07 YY = 01) CRC Off OnBit Error Rate exceeds the predetermined value.Check the transmission line and external equipment. PCM Off OnNo PCM signals arrive from the distant office.1.Check to see if the DTI...
Page 169
ND-45857 (E) CHAPTER 5 Page 145 Revision 3.0 INSTALLATION TEST 3.2 PLO Operation Test The following tests should be performed to confirm the PLO operation’s normality. • Clock Signal Generation Test • Clock Signal Synchronization Test To be performed when the PBX is a slave office. • Interoffice Synchronization Test 3.2.1 Clock Signal Generation Test This test checks to see if the PLO keeps generating clock signals at the frequency of the previous master clock, when the external clock signal from the...
Page 170
CHAPTER 5 ND-45857 (E) Pag e 1 46 Revision 3.0 INSTALLATION TEST 3.2.2 Clock Signal Synchronization Test This test checks to see if the PLO keeps synchronizing with the external clock signals, when the external clock signals from the master/sub-master office has input again after it has stopped once. To perform this test, an “In Service” transmission line is required. (1) When providing one clock supply route (from a master office) STEP 1: On the DTI card extracting clock signals (DTI0), set the SW-1 and...