Page 341
CHAPTER 6 NDA-24301 Pag e 3 24 Revision 1.0 SYSTEM OPERATION AND MAINTENANCE 3. Detail of Each Message a. “25-J” ZT Operation Start b. “25-K” ZT Set Up NGDetail message data 1: XX XX 00 00 00 00 00 00 - Detail message data 1: XX XX XXXX00 00 00 00 - Set UP NG KIND 00: ZT Restart Process 01: ZT Status Adjustment 02: ZT Bch Status Adjustment Set UP NG Factor 00~04 : Not Used. 05~08 : System-ID down load processing NG. 09~0A : System-ID down load processing timeout. 0B~0D : ZT Data down load processing NG....
Page 342
NDA-24301 CHAPTER 6 Page 325 Revision 1.0 SYSTEM OPERATION AND MAINTENANCE c. “25-L” ZT Fault 1: XX XX XXXX XX XX00 00 - Additional information Fault meaning 00: Fault report receive - Power ON execute 01: Fault report receive - Line Watchdog Detect 02: Fault report receive - Air Watchdog Detect 03: Fault report receive - Line Soft Detect 04: Fault report receive - Air Soft Detect 05: Fault report receive - Line-Air Detect 06: Fault report receive - LCCH Send Time Out 10: ZT Operation Stop 20: ZT Period...
Page 343
CHAPTER 6 NDA-24301 Pag e 3 26 Revision 1.0 SYSTEM OPERATION AND MAINTENANCE d. “25-M” ZT Fault recover 1: XX XX XXXX XX XX00 00 - Additional information Recover meaning 80: ZT Trouble Notification Recover 20: Fixed Period Diagnosis NG ZT Status Discrepant Recover Additional information XX XX PBX information 00: Inactive 01: Make busy 02: In Operation ZT information 00: Inactive 01: Make busy 02: In Operation 21: Fixed Period Diagnosis NG ZT Bch Status Discrepant Recover Additional information XX XXXX...
Page 344
NDA-24301 CHAPTER 6 Page 327 Revision 1.0 SYSTEM OPERATION AND MAINTENANCE e. “25-N” Carrier Fault f. “26-L” WIRELESS SYSTEM Failure Report1: XX XX XX XX XX XX XX XX Additional information (For NEC Engineer) Fault meaning 00:Carrier Close- 01:Carrier Change Detected ZT 1: XX XX XX XX XX00 - Additional information (For NEC Engineer) Fault Kind 01: ZT operation timer Write NG 02: ZT operation timer Read NG GL MG U