Page 51
NEAX2400 IPX Wireless Features and SpecificationsPage 46NDA-24313, Issue 1 C-155 Call Forwarding PS Incoming Call Incomplete Service Conditions (cont’d) 9. The incoming incomplete call to a Dterm PS can be transferred to other Dterm PS’s, stations, Attendant Consoles, Central Office and TIE lines when CALL FORWARDING PS INCOMING CALL INCOMPLETE is in service. 10. The timer value of incoming incomplete call is approximately eight seconds, time duration until the system recognizes that the D term PS is Out...
Page 52
NEAX2400 IPX Wireless Features and Specifications NDA-24313, Issue 1Page 47 Dterm PSII Two Line Operation D-155 D-155 Dterm PSII Two Line Operation General Description This feature allows for the appearance of two lines on the line (L1 and L2) keys of the PS. Operating Procedure No manual operation is required. Service Conditions 1. This feature is available for Series 7300 or later software. 2. Two kinds of lines can appear on the PS: My Line and Sub Line. These lines are associated with the telephone...
Page 53
NEAX2400 IPX Wireless Features and SpecificationsPage 48NDA-24313, Issue 1 N-43 Name Display - Intra-Node Call N-43 Name Display - Intra-Node Call General Description This feature allows a PS to indicate user information corresponding to the calling Physical Station Number while engaged in a station-to-station call. Operating Procedure When originating a station-to-station call: LCD display of the calling station: LCD display of the called station: When a station call has been transferred to another...
Page 54
NEAX2400 IPX Wireless Features and Specifications NDA-24313, Issue 1Page 49 Name Display - Intra-Node Call - CCIS N-44 N-44 Name Display - Intra-Node Call - CCIS General Description Between CCIS nodes this feature allows the calling or called party information to be displayed on the LCD of a PS. Operating Procedure When originating a call: LCD display of the calling station: LCD display of the called station: When a call has been transferred to another station by CALL FORWARDING - ALL CALLS/BUSY...
Page 55
NEAX2400 IPX Wireless Features and SpecificationsPage 50NDA-24313, Issue 1 N-45 Number Sharing N-45 Number Sharing General Description This feature allows the Dterm user to use a PS as a Sub Station. In this feature, the Dterm and PS are referred as Main Station and Sub Station, respectively. The main functions of this feature are as follows: 1. Call Forwarding - All Calls to PS - When the D term (Main Station) user presses the feature key or dials the access code, Call Forwarding - All Calls to PS (Sub...
Page 56
NEAX2400 IPX Wireless Features and Specifications NDA-24313, Issue 1Page 51 Number Sharing N-45 Service Conditions (cont’d) 9. When this feature is set while a call is terminating to Main Station, the call is not transferred to Sub Station. In this case, this feature is available from the next call. 10. Message Waiting Lamp control by MEASSAGE REMINDER or CMWL command is applied only to the called/designated station. 11. Even if this feature is set, recall to Main Station is not forwarded to Sub...
Page 57
NEAX2400 IPX Wireless Features and SpecificationsPage 52NDA-24313, Issue 1 V-24 Voice Mail Indication (VMI) V-24 Voice Mail Indication (VMI) General Description This feature allows the system to notify a PS that a voice mail has been received. Operating Procedure No manual operation is required. Service Conditions 1. This feature is available for Series 7300 or later software. 2. When a voice mail is received while the PS user is in conversation, the system notifies the PS after the conversion ends. 3....
Page 58
NEAX2400 IPX Wireless Features and Specifications NDA-24313, Issue 1Page 53 Wireless Analog Adjunct Connection W-8 W-8 Wireless Analog Adjunct Connection General Description This feature allows the existing PBX (no wireless function) to operate a PS as well as a station in the office. Each PS is connected with the dedicated COT in the Built-in Wireless system. When a call is originated from the PS, it terminates to the LC in the existing PBX via the corresponding COT and is handled by the existing...
Page 59
NEAX2400 IPX Wireless Features and SpecificationsPage 54NDA-24313, Issue 1 W-8 Wireless Analog Adjunct Connection Service Conditions (cont’d) 11. When a call terminates to the PS using this feature, the calling number is not displayed on the PS. 12. The following PBX services are available for PS’s using this feature: C.O. call origination C.O. call termination Intra-office services Common, the other services ISDN service Network service Call charging management service Maintenance...
Page 60
NEAX2400 IPX Wireless Features and Specifications NDA-24313, Issue 1Page 55 ISDN Roaming I-41 I-41 ISDN Roaming General Description This feature allows PS to move to another PBX which has a different SYS-ID via Q.931a connection. The PBX which PS can roam from/to is assigned Network Number (NWN). Network Number must be assigned as a unique number for each network. Operating Procedure 1. PS moves to another PBX which has a different SYS-ID. 2. PS registers its location automatically to the Home PBX at the...