Home > NEC > Communications System > NEC Neax 2400 Ipx System Operations And Maintenance Manual

NEC Neax 2400 Ipx System Operations And Maintenance Manual

Here you can view all the pages of manual NEC Neax 2400 Ipx System Operations And Maintenance Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 81

NDA-24307 CHAPTER 3
Page 53
Issue 1
SYSTEM MESSAGES
6-M Emergency Control Stop 129
6-N Abnormal Call Duration Data 130
6-O SMDR Output Buffer Overflow Alarm 133
6-P SMDR Output Buffer Overflow Release 136
7-A System Initialize With Data Load 137
7-B System Initialize 139
7-C CPU MBR Key Turn ON 140
7-D CPU MBR Key Turn OFF 141
7-E TSW MBR Key Turn ON 142
7-F TSW MBR Key Turn OFF 143
7-I ALMC MB Key Turn ON 144
7-J ALMC MB Key Turn OFF 145
7-K PM MB Key Turn ON 146
7-L PM MB Key Turn OFF 147
7-M NCU MB...

Page 82

CHAPTER 3 NDA-24307
Pag e 5 4
Issue 1
SYSTEM MESSAGES
13-P Digital Line Restore 198
13-Q DAU Battery Operation 199
13-R DAU Line Operation 200
13-Z Power Failure 201
15-A VPS Failure (Temporary) 202
15-B VPS Failure (Permanent) 203
15-C VPS Restore 204
16-A Inside Trunk All Busy 205
16-B Virtual Tie Line Set Report 207
16-C Virtual Tie Line Cancel Report 208
16-E Virtual Tie Line Set Time Out 209
16-F Sender Start Time Out 212
16-K I/O Port Line OFF 219
16-L I/O Port Line Restore 220
16-M Hard Clock...

Page 83

NDA-24307 CHAPTER 3
Page 55
Issue 1
SYSTEM MESSAGES
Note 1:
Refer to “Fusion Network System Manual.”
Note 2:Refer to the manual related to ATM.
Note 3:Refer to “Wireless System Manual.”
Note 4:Refer to the manual related to OAI. 23-P Dch Back-Up Automatic Change Start/End
240
23-Q Dch Back-Up Manual Change Start/End242
23-R ATM Interface Change Report Note 2-
23-S FCCH Failure Note 1-
23-T FCCH Failure Recovered Note 1-
23-U FCCH Status Notice Note 1-
23-W FCCH Advancing Start Note 1-
23-X FCCH Advancing...

Page 84

CHAPTER 3 NDA-24307
Pag e 5 6
Issue 1
SYSTEM MESSAGES
This message displays when the processor is reset due to a failure in the system.
➀ Self-CPU Restart Information
➁ Mate-CPU Restart Information (FF 
H: not mounted)
➂ Related-call Release Result
See Chapter 5 for repair procedure.
1: XXXX XX00 XXXX 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁ ➂
➃
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b4...

Page 85

NDA-24307 CHAPTER 3
Page 57
Issue 1
SYSTEM MESSAGES
➃Data Load Result after restart 
processing
Note 1:Phase 1 Restart is executed when initializing the system without disrupting the following two-way
connections that have already been established:
Basic two-way connections (STN-STN, STN-TRK, TRK-TRK)
Fixed connections
Two-way connections established on a Fusion link
For more details, see Chapter 6, Section 12.
Note 2:The number sharing data load also affects the data load of Dual Station Calling...

Page 86

CHAPTER 3 NDA-24307
Pag e 5 8
Issue 1
SYSTEM MESSAGES
This message displays when a fault has occurred to the clock oscillator in the CPU.
➀ Self-CPU Restart Information
➁ Mate-CPU Restart Information (FF 
H: not mounted)
➂ Related Call Information
See Chapter 5 for repair procedure.
1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
➂
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b5 b4 b3...

Page 87

NDA-24307 CHAPTER 3
Page 59
Issue 1
SYSTEM MESSAGES
C-level infinite loop is a state where a clock-level program, running under clock interrupt disable state, is in
an infinite loop. This message displays when the counter value to check the normality of the processing has
become abnormal.
➀ Self-CPU Restart Information after 
clock fault occurrence
➁ Mate-CPU Restart Information
➂ NMI Factor
See Chapter 5 for repair procedure.
0-E C-level Infinite Loop
1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3:...

Page 88

CHAPTER 3 NDA-24307
Pag e 6 0
Issue 1
SYSTEM MESSAGES
➃ System Controlling Port B
➄ CPU Alarm
➅ CPU Changeover Factors
➆ System ALM
➇ Data to be Analyzed by NEC 
Engineers b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b0: 0/1 = Timer 2 Gate ON/OFF
b1: 0/1 = Speaker Gate ON/OFF
b2: 0/1 = Parity Check Enable/MASK
b3: 0/1 = Channel Check Enable/MASK
b4: 0/1 = -/RAM Refresh Pulse Output State
b5: 0/1 = -/Timer 2 Output State
b6: 0/1 =...

Page 89

NDA-24307 CHAPTER 3
Page 61
Issue 1
SYSTEM MESSAGES
This message displays when a CPU memory read/write error occurs.
➀Information on Self-CPU Restart 
after detection of a clock fault
➁ Mate-CPU Restart Information
➂ NMI Factor
See Chapter 5 for repair procedure.
0-F Memory Failure
1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX
 
➀ ➁
➂ ➃
➄ ➅
➆
➇
4: XXXX XXXX XXXX XXXX 5: XXXX XXXX XXXX XXXX 6: XXXX XXXX XXXX XXXX
➇
7: XXXX XXXX XXXX XXXX 8: XX00 0000 0000 0000 9: 0000 0000 0000...

Page 90

CHAPTER 3 NDA-24307
Pag e 6 2
Issue 1
SYSTEM MESSAGES
➃ System Controlling Port B
➄ CPU Alarm
➅ CPU Changeover Factors
➆ System ALM
➇ Data to be Analyzed by NEC 
Engineers b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b0: 0/1 = Timer 2 Gate ON/OFF
b1: 0/1 = Speaker Gate ON/OFF
b2: 0/1 = Parity Check Enable/MASK
b3: 0/1 = Channel Check Enable/MASK
b4: 0/1 = -/RAM Refresh Pulse Output State
b5: 0/1 = -/Timer 2 Output State
b6: 0/1 =...