Page 51
NDA-24307 CHAPTER 2 Page 23 Issue 1 SYSTEM MAINTENANCE OUTLINE Pattern 2 When the system has a Fusion link with other IPX series and an NCN exists within the system If the system has a Fusion link also with other IPX series (i.e. the Fusion nodes exist also outside the system), an NCN can be assigned from either Local Nodes outside the system or the Local Nodes inside the system. In this example, LN0 of the IPX-U system is designated as the NCN. Figure 2-18 Example of NCN Assignment (2/3) Note 1: The...
Page 52
CHAPTER 2 NDA-24307 Pag e 2 4 Issue 1 SYSTEM MAINTENANCE OUTLINE Pattern 3 When the system has a Fusion link with other IPX series and an NCN exists outside the system If the system has a Fusion link also with other IPX series (i.e. the Fusion nodes exist also outside the system), an NCN can be assigned from either Local Nodes outside the system or the Local Nodes inside the system. In this example, LN-A (NEAX2400IPX series, 4-IMG type) outside the system is designated as the NCN. Figure 2-18 Example...
Page 53
NDA-24307 CHAPTER 2 Page 25 Issue 1 SYSTEM MAINTENANCE OUTLINE 2.5 System Messages System messages display during routine diagnosis, system operation status controlling, and fault occurrence. Figure 2-19 shows an example of a system message. Refer to Chapter 3 for details on each message. Figure 2-19 System Message Example (1) SYSTEM MESSAGE 3-E SUP LOCK UP FAILURE (TEMPORARY) (2) NEC TOKYO (3) LP00-0-ACT (4) 4:0000 0000 0000 0000 5:0000 0000 0000 0000 6:0000 0000 0000 0000 1:1102...
Page 54
CHAPTER 2 NDA-24307 Pag e 2 6 Issue 1 SYSTEM MAINTENANCE OUTLINE 2.6 Fault Detecting Function The system finds a fault by its fault detecting circuit and the fault detecting program. Once a fault occurs, the system initiates a remedial action such as system changeover, make-busy setting, or restart processing by the automatic diagnosis function. This action reduces the influence of the fault so that system servicing may be minimized. The result of the process taken and the fault situation are indicated...
Page 55
NDA-24307 CHAPTER 2 Page 27 Issue 1 SYSTEM MAINTENANCE OUTLINE Figure 2-20 Fault Detection General Diagram (via Alarm Lamps on TOPU) Indication of Fault Occurrence Information Collection and DiagnosisExample of Faults CPU Fault of line/trunk card TSW write failure, Fault of clocks, etc. Abnormal temperature, power supply failure, fuse blowing, etc., within the equipment frame CPU Fault of line/trunk card TSW write failure, Fault of clocks, etc. Abnormal temperature, power supply failure, fuse blowing,...
Page 56
CHAPTER 2 NDA-24307 Pag e 2 8 Issue 1 SYSTEM MAINTENANCE OUTLINE Figure 2-21 Fault Detection Block Diagram (via Display of System Messages) Indication of Fault Occurrence Information Collection and DiagnosisExample of Faults CPU Fault of line/trunk card TSW write failure, Fault of clocks, etc. Abnormal temperature, power supply failure, fuse blowing, etc., within the equipment frame CPU Fault of line/trunk card TSW write failure, Fault of clocks, etc. Abnormal temperature, power supply failure, fuse...
Page 57
NDA-24307 CHAPTER 2 Page 29 Issue 1 SYSTEM MAINTENANCE OUTLINE Figure 2-22 Fault Detection Block Diagram PWR PWR GT DLKC GT PWR GTGT DLKC To/From TSW of each LN MJ, MN fault Power, Fuse blown fault Temperature, CPU fault Speech Path System fault (SPE) RGU, Howler fault PFT fault CPU Clock fault Note: CPU EMAMMC To M AT, Printer, etc. Alarm Lamps on the TOPU Thermal Reed Relay RDY Clock etc. Howler Ringing Circuit Fault Information Note PWR Supply Failure, Fuse Blown Firmware Fault C-level...
Page 58
CHAPTER 2 NDA-24307 Pag e 3 0 Issue 1 SYSTEM MAINTENANCE OUTLINE (a) Main Faults Faults that may occur in the system can be generally categorized into Processor System Fault, Speech Path System Fault, Line/Trunk Fault, etc. Processor System Fault The CPU alarm detecting circuit continuously monitors whether the CPU is working normally. If a fault is detected, the CPU calls up the diagnostic program, which identifies the cause of the fault and determines whether the fault is temporary or permanent. When...
Page 59
NDA-24307 CHAPTER 2 Page 31 Issue 1 SYSTEM MAINTENANCE OUTLINE 2.7 Range of Faults Specification (1) Upon receiving a fault report from a station user or an operator, the technician can assume a faulty card exists if the range to be affected by the fault can be determined. For the detailed procedure, refer to Chapter 5. Use the following actions to check the MDF: (a) Check the LENS of the reporter (Station or ATTCON/DESKCON). (b) Check other circuits of the circuit card in which the reporter (station...
Page 60
CHAPTER 2 NDA-24307 Pag e 3 2 Issue 1 SYSTEM MAINTENANCE OUTLINE Figure 2-23 General System Block Diagram (1/2) HSW TSWM0TSWM1 TSWM0TSWM1 < ISW (Inter-node Switch) > ISAGT: PZ-GT13 LANI: PZ-PC19 IOGT: PH-GT10 TSW: PU-SW00 HSW: PU-SW01 PLO: PH-CK16/17-A EMA: PH-PC40 IOC: PH-IO24 < LN (Local Node) > ISAGT-A: PZ-GT13 ISAGT-B: PZ-GT20 LANI: PZ-PC19 GT: PH-GT09 TSW: PH-SW12 MUX:...