CHAPTER 2 SYSTEM MAINTENANCE OUTLINE
1. GENERAL
1.1 Purpose
This chapter explains the outline of fault diagnosis and duties necessary to maintain the PBX.
1.2 Administrative Management Procedures
Figure 2-1 shows the work flow of the administrative management procedures.
Figure 2-1   Flow of Administrative Management Procedures
Administrative
Management Works
Expansion and Change of
Station Users
Management Works
Diagnosis result, system message displays abnormality...

Page 32

CHAPTER 2 NDA-24307
Pag e 4
Issue 1
SYSTEM MAINTENANCE OUTLINE
1.3 How to Follow This Manual
Table 2-1 provides a brief description of the contents for each chapter in this manual.
2. BASIC KNOWLEDGE
This section identifies the information necessary for the system operations and maintenance procedures.
2.1 System Configuration
2.2 Line Equipment Numbers (LENS)
2.3 Local Partition (LP) Number
2.4 Assignment of Network Control Node (NCN)
2.5 System Messages
2.6 Fault Detecting Function
2.7 Range of Faults...

Page 33

NDA-24307 CHAPTER 2
Page 5
Issue 1
SYSTEM MAINTENANCE OUTLINE
2.1 System Configuration
Figure 2-2 shows the system configuration of the fully expanded NEAX2400 IPX IPX-U.
Figure 2-2   NEAX2400 IPX IPX-U
......
......
LN0
ISWLN1
LN3 LN2
FRONT VIEW
ISW: Inter-node Switch
LN: Local Node 

Page 34

CHAPTER 2 NDA-24307
Pag e 6
Issue 1
SYSTEM MAINTENANCE OUTLINE
2.1.1 Configuration of the System
The NEAX2400 IPX IPX-U system (referred to in the remainder of this manual as “the system”) is
configured by a single Inter-node Switch (ISW) and a maximum of 4 Local Nodes (LNs). Refer to
figures in this section. The ISW and LNs are connected via the Fusion link, with Ethernet and physical
PCM cables connected to each other. Figure 2-3 provides an overall image of system configuration. A
two-module ISW and...

Page 35

NDA-24307 CHAPTER 2
Page 7
Issue 1
SYSTEM MAINTENANCE OUTLINE
Figure 2-4   Details on Inter-node PCM Cable Connections Note:
For actual cable runnings, refer to the Installation Manual.
IS W
BASEULPM IS W MTO PU
<  IS W M  B ackplane >
For TSWM1
For TSWM0
(17) (16) (15) (14) (07) (06) (05) (04)
LN0
IM G 0       IM G 1       IM G 2       IM G 3
BASEU BASEU BASEU BASEULPM TSWM0 TSWM1 DUMMY
PIM1 PIM1 PIM1 PIM1
PIM0 PIM0 PIM0 PIM0 FANU FANU FANU FANUPIM2 PIM2 PIM2 PIM2 PIM3 PIM3 PIM3 PIM3 TOPU TOPU TOPU...

Page 36

CHAPTER 2 NDA-24307
Pag e 8
Issue 1
SYSTEM MAINTENANCE OUTLINE
Figure 2-5   Details on Ethernet Cable Connections (Establishment of Fusion Link) (1/2)
ISW
CPU1
HUB1
HUB0
PIM0 of LN0, IMG010 BASE-T Cables (Straight)
10 BASE-T Cables (Straight) 10 BASE-T 
        Cables 
       (Cross)
CPU1
LPM PIM0CPU0
00
00
LANI
HUB0 HUB1NoteNote
IMG0 (LN0)
From ISW From LN1 From LN2 From LN3
From ISW From LN1 From LN2 From LN3
LPM
CPU1
CPU000
00
LANI
ISW / IMG0 (LN1/2/3)
Max. 328 ft (100m)Note 2
: 10 BASE-T connector...

Page 37

NDA-24307 CHAPTER 2
Page 9
Issue 1
SYSTEM MAINTENANCE OUTLINE
Figure 2-5  Details on Ethernet Cable Connections (Establishment of Fusion Link) (2/2)
[ Details on Ether Cable Connections: When Dual LANIs are used for each CPU ]
When dual LANIs are used for each CPU, the whole second LANIs (external LANI:  PCI slot 03) must also be
connected in addition to the first LANIs explained on the previous page.  This figure shows an example where the
second LANIs are connected to the additional HUB2/HUB3 (PA-M96)...

Page 38

CHAPTER 2 NDA-24307
Pag e 1 0
Issue 1
SYSTEM MAINTENANCE OUTLINE
Figure 2-6   Details on Ethernet Cable Connections (Using MAT via Ethernet) Note:
The LANI card for MAT connection is mounted in PCI slot No. 01 of each CPR.
[ Details on Ether Cable Connections: When using MAT via Ethernet ] 
 
 
CPU1
LPM PIM0CPU0
01
0100
00
HUB
LANI
IMG0 (LN1)
ISW
Fusion Link
Ether for MATLN0 LN1 LN2 LN3
LN1IMG0 IMG1 IMG2 IMG3
MAT
MAT
10 BASE-T Cable 
       (Straight)10 BASE-T Cable 
       (Straight)
10 BASE-T Cable...

Page 39

NDA-24307 CHAPTER 2
Page 11
Issue 1
SYSTEM MAINTENANCE OUTLINE
Figure 2-7   Face Layout of ISW
03 04IOC (PH-IO24)EMA (PH-PC40)
13 14
01 02MMC (PH-M22)
00 01 02 03 04 05 06 07 08 1011 16 17 18 1915PWR0  (PH-PW14)HSW00 (PU-SW01)TSW00 (PU-SW00) IOGT0 (PH-GT10)
PWR1  (PH-PW14) HSW01 (PU-SW01)
TSW01 (PU-SW00) TSW02 (PU-SW00)
TSW03 (PU-SW00) PLO0PLO1
00
IOGT1 (PH-GT10) TSW10 (PU-SW00) TSW11 (PU-SW00)
TSW12 (PU-SW00)
TSW13 (PU-SW00)
HSW10 (PU-SW01)HSW11 (PU-SW01)
(PH-CK16-A/17-A)
(PH-CK16-A/17-A)
(RES)
(RES)...

Page 40

CHAPTER 2 NDA-24307
Pag e 1 2
Issue 1
SYSTEM MAINTENANCE OUTLINE
Figure 2-8   Face Layout of IMG0 (Local Node) Note:
The 2nd IOC card (optional) may be mounted in this slot.
000102030405060708091011121314151617181920212223
000102030405060708091011121314151617181920212223
00
00
01
01
02
02
03
03
04
04
05060708091011121314151617181920212223
000102030405060708091011121314151617181920212223
 LPM PIM 0 PIM 1 FA N UPIM 2 PIM 3  TO P U
 BASEU
PH-PC40 (EMA)
PH-IO24 (IOC)
PWR1
PWR0 PWR1
PWR0 PWR1
PWR0 PWR0 PWR1...