Page 61

NDA-24307 CHAPTER 2
Page 33
Issue 1
SYSTEM MAINTENANCE OUTLINE
Figure 2-23  General Block Diagram of the Whole System (2/2)
TSWM0TSWM1
TSWM0TSWM1
MISCIOCEMA
HSW
PLO
MISCIOCEMA
MISCIOCEMA
PLO
GT
ISAGT-B
TSW00TSW01TSW02TSW03
TSW00TSW01TSW02TSW03
TSW00TSW01TSW02TSW03
TSW00TSW01TSW02TSW03
IOGT
ISAGT
CPU
LANI
GT
ISAGT-A
CPULANI
Fusion Link
ISWLN2LN3
To TSW
of LN0To TSW
of LN1
To PLO of
  LN0/1
DLKC
GT
ISAGT-A
GT
ISAGT-B
CPULANI
TSW00TSW01TSW02TSW03
DLKCPLOCLK
To MUX
(IMG0)To MUX
(IMG1)
To MUX
(IMG0)To MUX...

Page 62

CHAPTER 2 NDA-24307
Pag e 3 4
Issue 1
SYSTEM MAINTENANCE OUTLINE
Figure 2-24   CPU Controlling Block Diagram (ISW)
LPM of ISW
EMAIOC /
MISC
ISAGT 0
LANI
PWR
PWR
CPU 0
MEMORY
PCI BUSISA BUS
CPU board CPR
CPU clock
   CPR
(ST-BY)Reset Signal
(ST-BY)
MISC BUS
MISC BUS
T
M
IOGT 1IOGT 0IOP1IOP0
ISAGT 1CPU board
T
M
Fusion Link
PLO 0
PLO 1
MISC BUS MISC BUS
To TSWM1 of LN3
To TSWM0 of LN3
To TSWM1 of LN2
To TSWM0 of LN2
To TSWM1 of LN1
To TSWM0 of LN1
000 001
002
003
004
005
006
007
008
009
00A
00B
00C
00D
00E...

Page 63

NDA-24307 CHAPTER 2
Page 35
Issue 1
SYSTEM MAINTENANCE OUTLINE
Figure 2-25   CPU Controlling Block Diagram (LN)
EMAIOC /
MISCLANI
PWR
PWR
CPU 0
MEMORY
PCI BUSISA BUS
CPU board CPR
CPU clock
Reset Signal
(ST-BY)
MISC BUS
MISC BUS
TSWM 1 of LN0  
TSW 00TSW 01TSW 11TSW 10
CLK 0CLK 1
GT 1
GT 0IOP1
IOP0
TSW/INT TSW/INT TSW/INTTSW/INT
MUXMUXMUXMUXMUXMUXMUXMUXMUXMUXMUXMUXMUXMUXMUXMUXTSW
     02
TSW/
   INT
TSW 
     03
TSW/
   INT
TSW
     13
TSW/
   INT
TSW
     12
TSW/
   INT
TSW I/O
MISC BUS MISC BUS
BUS
TSW...

Page 64

CHAPTER 2 NDA-24307
Pag e 3 6
Issue 1
SYSTEM MAINTENANCE OUTLINE
Figure 2-26   Speech Path Block Diagram (1/2)
ISWM
MUXMUXLC/TRKPIM0
IMG0 of LN0
PIM1MUXMUXLC/TRK
PIM2MUXMUXLC/TRK
PIM3MUXMUXLC/TRK
MUXMUXLC/TRKPIM0
IMG1 of LN0
PIM1MUXMUXLC/TRK
PIM2MUXMUXLC/TRK
PIM3MUXMUXLC/TRK
MUXMUXLC/TRKPIM0
IMG2 of LN0
PIM1MUXMUXLC/TRK
PIM2MUXMUXLC/TRK
PIM3MUXMUXLC/TRK
MUXMUXLC/TRKPIM0
IMG3 of LN0
PIM1MUXMUXLC/TRK
PIM2MUXMUXLC/TRK
PIM3MUXMUXLC/TRK
- Symbols -
:  Cable:  Circuit card (ACT)
:  Circuit card (ST-BY)
:...

Page 65

NDA-24307 CHAPTER 2
Page 37
Issue 1
SYSTEM MAINTENANCE OUTLINE
Figure 2-26  Speech Path Block Diagram (2/2)
ISWM
MUXMUXLC/TRKPIM0
IMG0 of LN2
PIM1MUXMUXLC/TRK
PIM2MUXMUXLC/TRK
PIM3MUXMUXLC/TRK
MUXMUXLC/TRKPIM0
IMG1 of LN2
PIM1MUXMUXLC/TRK
PIM2MUXMUXLC/TRK
PIM3MUXMUXLC/TRK
MUXMUXLC/TRKPIM0
IMG2 of LN2
PIM1MUXMUXLC/TRK
PIM2MUXMUXLC/TRK
PIM3MUXMUXLC/TRK
MUXMUXLC/TRKPIM0
IMG3 of LN2
PIM1MUXMUXLC/TRK
PIM2MUXMUXLC/TRK
PIM3MUXMUXLC/TRK
- Symbols -
:  Cable
:  Circuit card (ACT)
:  Circuit card (ST-BY)
:  Speech...

Page 66

CHAPTER 2 NDA-24307
Pag e 3 8
Issue 1
SYSTEM MAINTENANCE OUTLINE
Figure 2-27   Speech Path Range of Fault
MUX
A fault within this range
affects this module.
32ch
A fault within this range 
affects the circuit card.A fault within this range affects two slots.
PIM 3
A fault within this range
affects this module.
32ch
A fault within this range 
affects the circuit card.A fault within this range
affects two slots.
PIM 3
A fault within this range
affects this module.
32ch
A fault within this range 
affects...

Page 67

NDA-24307 CHAPTER 2
Page 39
Issue 1
SYSTEM MAINTENANCE OUTLINE
2.8 Explanation of Terms
C-Level Infinite Loop
The program repeatedly executes specific routines due to a fault of the main memory, data destruction,
etc. The program is not able to be processed normally. This faulty condition is referred to as Program
Infinite Loop. C-Level infinite loop is a state where a clock-level program, which runs under clock
interrupt disable state, is in an infinite loop status.
B-Level Infinite Loop
This is a...

Page 68

CHAPTER 2 NDA-24307
Pag e 4 0
Issue 1
SYSTEM MAINTENANCE OUTLINE
PM (Line/Trunk Card) Make-Busy Restart
In this processing, the faulty PM (Line/Trunk Card) is isolated from the system and, at the same time,
the calls associated with that faulty PM (Line/Trunk Card) are released. No calls related to the faulty
PM (Line/Trunk Card) are processed and the system normally runs without the faulty PM (Line/Trunk
Card).
Data Copy Restart
In a system of dual CPU configuration, the RAM memory (including the data...

Page 69

NDA-24307 CHAPTER 2
Page 41
Issue 1
SYSTEM MAINTENANCE OUTLINE
3. HOW TO READ PRECAUTIONS, DIAGNOSTIC, AND FAULT REPAIR INFORMATION
3.1 Precaution about Diagnostic Procedure/Fault Repair Procedure
When performing diagnostic procedures/fault repair procedures, be aware of the following actions:
(1) When replacing a circuit card with a spare, handle the circuit card using the Field Service Kit.
(a) To protect the circuit card from static electricity, wear a wrist strap before handling the circuit card.
(b)...

Page 70

CHAPTER 2 NDA-24307
Pag e 4 2
Issue 1
SYSTEM MAINTENANCE OUTLINE
Figure 2-29   How to Hold a Circuit Card
(3) When a circuit card appears to be faulty, check the following items before replacing it with a spare:
(a) Poor connector contact at the circuit card may be responsible for the fault. Repeat insertion and
extraction of the circuit card a few times. Clean the connector portion, and recheck for proper
operation.
(b) Check the lead wires of vertically-mounted parts (resistors, capacitors, etc.) to...