    							CHAPTER 4 NDA-24299
    Page 46
    Revision 1.0
    INSTALLATION
    Connecting Cables
    4.2 Connecting 10 BASE-T Cables
    Figure 4-11 shows sample cable connections, where HUB (PA-M96) cards are provided in a dual
    configuration and the FCH (PA-FCHA) card is located in PIM 1 (1-IMG system/IMG0). When HUB cards
    are provided in a dual configuration, the two HUB cards must be connected on each front edge connector
    with a 10 BASE-T cross cable. However, when dual LANIs (LANI-A and LANI-B) are used for each CPU,
    the cross cable connection between HUBs for FCH#0 and #1 is not necessary.
    Note:The Ethernet cables shown in the examples in this section are NOT available from NEC. The customer must
    provide these cables, depending on the system configuration. See “Chapter 6 Connecting 10 BASE-T
    Cables.”
    Figure 4-11   Overall 10 BASE-T Connections Note:
    When connecting the MAT using a HUB card, be sure to use a dedicated HUB for the MAT.
    ATTENTIONContents
    S ta tic S e nsitive
    Handling
    Precautions Required
    DTI (PA-24DTR)
     
    DTI
    LANI (PZ-PC19)
    LANI (PZ-PC19)
    10 BASE T cable
    (straight)
    10 BASE T cable
    (straight)
    :  10 BASE-T cable (for Fusion Link):  10 BASE-T cable (for MAT)
    MAT
    P
    IM
     
    1
    P
    I
    M
     
    0  
     
     
     
     H
    U
    B
     
    (PA
    -
    M9
    6
    )
     
      
     
     
     
    HU
    B 
    (P
    A
    -M
    96
    ) 
     
     
     
      
    H
    U
    B 
    (PA
    -M9
    6
    )
    GT
    GT
    to MAT
    REAR VIEW
    Note
    10 BASE T cable
    (cross)
    FCH (PA-FCHA) 
    						
    							NDA-24299 CHAPTER 4
    Page 47
    Revision 1.0
    INSTALLATION
    Connecting Cables
    4.3 10 BASE-T Connection Procedure
    The pattern for 10 BASE-T cable connections may vary, depending on the system configuration (such as
    the number of IMG stacks or the mounting location/number of the FCH/HUB cards, etc.). According to
    your system configuration, connect necessary Ethernet cables:
    4.3.1 Procedure for 1-IMG System
    If your system is 1-IMG type, the 10 BASE-T connection should use either of the following cables:
    1. Cable unit specified as SR1201 ETIF CAU-n
    2. Cables, other than those of SR1201 ETIF CAU-n, that are provided by the user
    Based on the cable type, perform the following:
    4.3.2 When using cable unit SR1201 ETIF CAU-n
    1. Referring to Figure 4-13 through Figure 4-15, connect the 10 BASE-T straight cables, between the
    LANI (PZ-PC19) and HUB (PA-M96) cards, and between the HUB and FCH (PA-FCHA) cards. If
    the HUB is in a dual configuration, also connect the 10 BASE-T cross cable between HUB#0 and
    HUB#1.
    When dual LANIs are used in both Slot 00 and 03 of CPR#0/CPR#1, be sure to use at least two
    HUB cards. Use one HUB for the internal LANI (in Slot 00), and use the other HUB for external
    LANI (in Slot 03). If FCH is also in a dual configuration, the 10 BASE-T cross connection between
    the two HUBs is not required. 
    2. If your system needs more FCH (PA-FCHA) and/or HUB (PA-M96) cards, provide the required
    Ethernet connection(s) for the added card(s) using the following cables:
     When adding FCH card in PIM0: UTP CTG5 ST CA-D
     When adding HUB card in PIM0: UTP CTG5 CRS CA-D
     When adding FCH card in PIM1: UTP CTG5 ST CA-K
     When adding HUB card in PIM1: UTP CTG5 CRS CA-K
     When adding FCH card in PIM2: UTP CTG5 ST CA-M
     When adding HUB card in PIM2: UTP CTG5 CRS CA-M
     When adding FCH card in PIM3: UTP CTG5 ST CA-N
     When adding HUB card in PIM3: UTP CTG5 CRS CA-N
    Note:The cables cited above and used in Figure 4-13 through Figure 4-15 are for the 1-IMG system only and are
    not available in the 4-IMG/IMX-U system. 
    						
    							CHAPTER 4 NDA-24299
    Page 48
    Revision 1.0
    INSTALLATION
    Connecting Cables
    4.3.3 When not using the cable unit SR1201 ETIF CAU-n
    When your system doesn’t use the cable unit classified as SR1201 ETIF CAU-n, perform the 10 BASE-
    T connections as instructed below:
    1. Depending on your system configuration, connect the 10 BASE-T straight cable(s) between the
    HUB (PA-M96) and LANI (PZ-PC19) cards. Use the cable UTP CTG5 ST CA-O, which must be
    provided by the user.
    When a single LANI is used for each CPR (Slot 00 only), and the HUB is in a dual configuration,
    connect HUB#0 to LANI#0 and HUB#1 to LANI#1, using two 10 BASE-T cables.
    When dual LANIs are used in both Slot 00 and 03 of CPR#0/CPR#1, use at least two HUB cards
    as separate 10 BASE-T connection terminals: One HUB for the internal LANI (LANI-A in Slot 00
    of each CPR) and the other for the external LANI (LANI-B: in Slot 03 of each CPR). 
    2. When HUB is in a dual configuration, connect the 10 BASE-T cross cable between the HUB cards.
    Use the cable UTP CTG5 CRS CA-F, which must be provided by the user.
    When using more than two HUB cards, connect the cross cable(s) for the remaining HUB cards,
    except the HUB card used for the MAT connection.
    3. Connect the 10 BASE-T straight cable(s) between the HUB and FCH (PA-FCHA) cards. Use the
    following cables, which must be provided by the user.
    UTP CTG5 ST CA-F:When the HUB and FCH are in the same PIM (PIM0)
    UTP CTG5 ST CA-O:When the HUB and FCH are in different PIMs
    When FCH is in a dual configuration, connect FCH#0 to the HUB#0 side, and FCH#1 to the HUB#1
    side.
    4.3.4 Procedure for 4-IMG System
    When your system is 4-IMG type, the procedure for 10 BASE-T connection is as follows. Because the
    HUB (PA-M96) can be mounted anywhere in a PIM of any IMG, the Ethernet cables must be arranged
    by the user, depending on the system configuration.
    1. Depending on your system configuration, connect the 10 BASE-T straight cable(s) between the
    HUB (PA-M96) and LANI (PZ-PC19) cards. Use the following cables, prepared by the user:
    UTP CTG5 ST CA-O:When the HUB and LANI are in the same IMG (IMG0)
    UTP CTG5 ST CA-X:When the HUB and LANI are in different IMGs
    When a single LANI is used for each CPR (Slot 00 only), and the HUB is in a dual configuration,
    connect HUB#0 and HUB#1 to LANI#1 using two 10 BASE-T cables. 
    						
    							NDA-24299 CHAPTER 4
    Page 49
    Revision 1.0
    INSTALLATION
    Connecting Cables
    When dual LANIs are used in both Slot 00 and 03 of CPR#0/CPR#1, be sure to use at least two
    HUB cards as separate 10 BASE-T connection terminals. Use one HUB for the internal LANI
    (LANI-A: in Slot 00 of each CPR), and use the other for the external LANI (LANI-B in Slot 03 of
    each CPR).
    2. When the HUB is in a dual configuration, connect the 10 BASE-T cross cable between the HUB
    cards. Use the following cables, which are provided by the user.
    UTP CTG5 CRS CA-F:When the HUB and HUB are in the same PIM
    UTP CTG5 CRS CA-O:When the HUB and HUB are in different PIMs but in the same IMG
    UTP CTG5 CRS CA-X:When the HUB and HUB are in different IMG stacks
    When using more than two HUB cards, also connect the cross cable(s) for the remaining HUB
    card(s), except the HUB for the MAT connection.
    This step is not necessary when your system uses dual LANIs for CPU#0/CPU#1 and FCH is also
    in a dual configuration.
    3. Connect the 10 BASE-T straight cable(s) between the HUB and FCH (PA-FCHA) cards. Use the
    following cable, which must be provided by the user.
    UTP CTG5 ST CA-F:When the HUB and FCH are in the same PIM
    UTP CTG5 ST CA-O:When the HUB and FCH are in different PIMs but in the same IMG
    UTP CTG5 ST CA-X:When the HUB and FCH are in different IMG stacks
    When FCH is in a dual configuration, connect FCH#0 to the HUB#0 side and FCH#1 to the HUB#1
    side.
    4.3.5 Procedure for IPX-U and IMX-U Systems
    When your system is the IPX-U or IMX-U type (configured to a maximum of 4 Local Nodes + 1ISW),
    the procedure for the 10 BASE-T connection is as follows. Because this system already has a Fusion
    link via the HUB (PA-M96) cards, this section gives details related only to the connection between the
    HUB and FCH (PA-FCHA) cards.
    1. Refer to the NEAX2400 IPX Installation Manual (IMX-U Type) or the NEAX2400 IMX
    Installation Manual (IMX-U Type) to make sure that the necessary 10 BASE-T (both straight and
    cross) connections between the ISW and each LN (Local Node) are all securely provided.
    2. Connect the 10 BASE-T straight cable(s) between the HUB (PA-M96) and FCH (PA-FCHA) cards.
    Use the following cable, which must be provided by the user.
    UTP CTG5 ST CA-F:When the HUB and FCH are in the same PIM
    UTP CTG5 ST CA-O:When the HUB and FCH are in different PIMs but in the same IMG
    UTP CTG5 ST CA-X:When the HUB and FCH are in different IMG stacks but in the same LN
    UTP CTG5 ST CA-A0:When the HUB and FCH are in different LNs 
    						
    							CHAPTER 4 NDA-24299
    Page 50
    Revision 1.0
    INSTALLATION
    Connecting Cables
    When dual FCH is provided for the HUB dedicated to each internal LANI card (LANI-A: in Slot
    00 of each CPR), connect FCH#0 to HUB#0 and FCH#1 to HUB#1.
    When your system also uses the external LANI cards (LANI-B in Slot 03 of each CPR), prepare
    another set of FCH cards for the HUB dedicated to the external LANI cards. Then, if the FCH is in
    dual configuration, connect one FCH to the HUB for No. 0 system of the external LANI, and the
    other to the HUB for the No. 1 system of the external LANI.
    Figure 4-12 shows an example of a HUB in a dual configuration and the FCH card mounted in PIM
    1 of the 1 IMG system.
    Figure 4-12   Connecting 10 BASE-T Cables (example)
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    DTI
     
    2
    3
    3
    Connect HUB and FCH using a 
    10 BASE-T straight cable.  
    R efer to fig ure s  listed  on  the   
    following pages.
    DTI
    FCH
    LANI
    LANI
    PI
    M 
    1
    PI
    M 
    0  
     
      
     
    HU
    B 
    (PA-
    M
    9
    6
    )
      
     
      
     
     HU
    B
    (
    PA
    -M
    9
    6
    )
    GT
    GT
    2
    Connect two HU B cards using 
    a 10 BA SE-T cross cable.  
    (W hen HUB is in dual  
    configuration.) Note
    -
    1
    1
    Connect the LANI and the  
    HUB  card using a 10 BASE-T 
    straight cable. Eight  
    10 BASE-T connectors 
    (T P 0 -X   -  TP 7-X ) are  
    furnished on the front edge 
    of the HUB card. Use one of  
    the connectors.
    1
    Note
    Note
    Note:This step can be skipped when dual LANIs (LANI-A and LANI-B) are used for each CPU and FCH is
    provided in a dual configuration. 
    						
    							NDA-24299 CHAPTER 4
    Page 51
    Revision 1.0
    INSTALLATION
    Connecting Cables
    Figure 4-13 shows some typical examples where 10 BASE-T cables are connected to the FCH card(s) mounted
    in PIM0 of 1-IMG system, under the conditions in Table 4-6:
    Table 4-6 Connection of 10 BASE-T Cables to FCH Card(s) in PIM0 of 1-IMG
    Note 1:
    Cables Contained in each cable unit are as follows:
    SR1201 ETIF CAU-A: UTP CTG5 ST CA-D, UTP CTG5 ST CA-J
    SR1201 ETIF CAU-DA: UTP CTG5 ST CA-D, UTP CTG5 ST CA-J, UTP CTG5 CRS CA-F
    Note 2:The cables cited in Figure 4-13 can be used in the 1-IMG system only.  
    Figure 4-13   Examples of Ethernet Cable Connection-FCH in PIM0 (1-IMG System) (1/2)Configuration
    of CPUConfiguration
    of LANUsed Cable Unit
    (Note 1, Note 2)Number of HUB/
    FCH
    Pattern 1 Single Single SR1201 ETIF CAU-A × 1 HUB× 1, FCH× 1
    Pattern 2 Dual SingleSR1201 ETIF CAU-A × 1
    SR1201 ETIF CAU-DA × 1HUB× 2, FCH× 2
    Pattern 3 Single Dual SR1201 ETIF CAU-A × 2 HUB× 2, FCH× 2
    Pattern 4 Dual DualSR1201 ETIF CAU-A × 2
    SR1201 ETIF CAU-DA × 2HUB× 2, FCH× 2
    ATTENTIONContents
    Static Sensitive
    Handling
    P reca ution s Required
    BSCM
    06 04 05 03 02 01 0006 04 05 03 02 01 00
    CNCN
    HUB
    BASEU
    PIM 1
    PIM 2
    PIM 3
    UTP CTG5 ST CA-J
    PIM 0
    LPM FANU
    FCH
    CNCN
    UTP CTG5 ST CA-D
    TO PU
    FCH (PA-FCHA)HUB (P A-M 96)
    TP0-X TP1-X TP2-X TP3-X TP4-X TP5-X
    TP6-X
    TP7-X
    10 BASE-T
    Connectors for 10 BASE-T
    FRONT VIEWFRONT VIEW
    CN= 10  BASE-T Connector
    Use 10 BASE-T connectors. 
    BSCM06 04 05 03 02 01 00
    06 04 05 03 02 01 00
    CN
    CN
    CN
    CN
    UTP CTG5 ST CA-J
    CNFCH
    HUB
    CN
    CNHUB
    BASEU
    PIM 1
    PIM 2
    PIM  3
    LPM
    CN
    < F C H  in P IM 0 (P attern  1)>   < FC H  in P IM 0 (Pa ttern 2)>  
    PIM  0
    UTP CTG5 CRS CA-F
    CN
    FCHCN
    UTP CTG5 ST CA-D
    TO PU
    FANU 
    						
    							CHAPTER 4 NDA-24299
    Page 52
    Revision 1.0
    INSTALLATION
    Connecting Cables
    Figure 4-13   Examples of Ethernet Cable Connection-FCH in PIM0 (1-IMG System) (2/2)
    ATTENTIONContents
    Static S ensitive
    Handling
    Precautions Required
    06 04 05 03 02 01 0006 04 05 03 02 01 00
    CN
    CN
    CNCN
    HUB
    CN
    CNHUB
    BASEU
    PIM 1
    PIM 2
    PIM 3
    UTP CTG5 ST CA-J
    PIM 0
    LPMTOPU
    FANU
    BSCM
    CN
    FC H
    CN
    UTP CTG5 ST CA-J
    FCH
    CNCN
    UTP CTG5 ST CA-D
    < F C H  in P IM 0  (P attern 3)>   < F C H  in P IM 0 (P a ttern  4)>  
    06 04 05 03 02 01 00
    06 04 05 03 02 01 00
    CN
    CN
    CN
    CN
    CNCN
    CNUTP CTG5 ST CA-J
    CN FCH
    HUB
    CN
    CNHUB
    BASEU
    PIM 1
    PIM 2
    PIM 3
    LPM
    CN
    CN
    TOPU
    FANU
    PIM 0CNFC HCN
    UTP CTG5 ST CA-D
    UTP CTG5 ST CA-J
    BSCM
      
               
               
               Note:When dual LANIs are used in both slot 00 and 03 of OPR (Pattern 3 or 4), be sure to use at least two
    HUB cards: One HUB for internal LANI (in slot 00) and the other for external LANI (in slot 03).
    However, if this is the case, and FCH is also in a dual configuration, the 10 BASE-T “cross” connection
    between the HUBs is not required. 
    						
    							NDA-24299 CHAPTER 4
    Page 53
    Revision 1.0
    INSTALLATION
    Connecting Cables
    Figure 4-14 shows some typical examples where 10 BASE-T cables are connected to the FCH card(s) mounted
    in PIM1 of 1-IMG system, under the conditions in Table 4-7:
    Table 4-7 Connection of 10 BASE-T Cables to FCH Card(s) in PIM1 of 1-IMG
    Note 1:
    Cables contained in each cable unit are as follows:
    SR1201 ETIF CAU-B: UTP CTG5 ST CA-K, UTP CTG5 ST CA-J
    SR1201 ETIF CAU-DB: UTP CTG5 ST CA-I, UTP CTG5 ST CA-J, UTP CTG5 CRS CA-F
    Note 2:The cables cited in Figure 4-14 can be used in the 1-IMG system only.
    Figure 4-14   Examples of Ethernet Cable Connection-FCH in PIM1 (1-IMG System)Configuration
    of CPUConfiguration
    of LANUsed Cable Unit
    (Note 1, Note 2)Number of HUB/
    FCH
    Pattern 1 Single Single SR1201 ETIF CAU-B × 1 HUB× 1, FCH× 1
    Pattern 2 Dual SingleSR1201 ETIF CAU-B × 1
    SR1201 ETIF CAU-DB × 1HUB× 2, FCH× 2
    Pattern 3 Single Dual SR1201 ETIF CAU-B × 2 HUB× 2, FCH× 2
    Pattern 4 Dual DualSR1201 ETIF CAU-B × 2
    SR1201 ETIF CAU-DB × 2HUB× 2, FCH× 2
    ATTENTIONContents
    Static Sensitive
    H andling
    Precautions Required
    06 04 05 03 02 01 0006 04 05 03 02 01 00
    CNCN
    HUB
    BASEU
    PIM 1
    PIM 2
    PIM 3
    UTP CTG5 ST CA-J
    PIM 0
    LPM TO PU
    FA NU
    BSCM
    FCH
    CN
    CN
    UTP CTG5 ST CA-K
    BSCM06 04 05 03 02 01 00
    06 04 05 03 02 01 00
    CN
    CN
    CN
    CN
    UTP CTG5 ST CA-J
    CNFCH
    HUB
    CN
    CN HUB
    BASEU
    PIM 1
    PIM 2
    PIM 3
    LPM
    CN
    TOPU
    FANU
    PIM 0
    UTP CTG5 CRS CA-F
    CNFCH
    CNUTP CTG5 ST CA-K
    UTP CTG5 ST CA-I
    < FC H  in  P IM 1 (P attern  1)>   < FC H  in P IM 1 (P attern 2)>  
    FCH (PA-FCHA)HUB (PA-M96)
    TP0-X TP1-X TP2-X TP3-X TP4-X TP5-X TP6-X TP7-X
    10 BASE-T
    C on n ec to rs fo r 1 0 BA S E-T
    FR ONT VIEWFRO NT VIEW
    CN= 10  BASE-T  Connector
    Use 10 BASE-T connectors.  
    						
    							CHAPTER 4 NDA-24299
    Page 54
    Revision 1.0
    INSTALLATION
    Connecting Cables
    Figure 4-15 shows some typical examples where 10 BASE-T cables are connected to the FCH card(s) mounted
    in PIM2 of 1-IMG system, under the conditions in Table 4-8:
    Table 4-8 Connection of 10 BASE-T Cables to FCH Card(s) in PIM2 of 1-IMG 
    Note 1:
    Cables contained in each cable unit are as follows:
    SR1201 ETIF CAU-C: UTP CTG5 ST CA-M, UTP CTG5 ST CA-J
    SR1201 ETIF CAU-DC: UTP CTG5 ST CA-K, UTP CTG5 ST CA-J, UTP CTG5 CRS CA-F
    Note 2:The cables cited in Figure 4-15 can be used in the 1-IMG system only.
    Figure 4-15   Examples of Ethernet Cable Connection-FCH in PIM2 (1-IMG System) (1/2)Configuration
    of CPUConfiguration
    of LANUsed Cable Unit
    (Note 1, Note 2)Number of HUB/
    FCH
    Pattern 1 Single Single SR1201 ETIF CAU-C × 1 HUB× 1, FCH× 1
    Pattern 2 Dual SingleSR1201 ETIF CAU-C × 1
    SR1201 ETIF CAU-DC × 1HUB× 2, FCH× 2
    Pattern 3 Single Dual SR1201 ETIF CAU-C × 2 HUB× 2, FCH× 2
    Pattern 4 Dual DualSR1201 ETIF CAU-C × 2
    SR1201 ETIF CAU-DC × 2HUB× 2, FCH× 2
    ATTENTIONContents
    Static S ensitive
    Handling
    Precautions Required
    06 04 05 03 02 01 0006 04 05 03 02 01 00
    CNCN
    HUB
    BASEU
    UTP CTG5 ST CA-J
    FAN U
    BSCM
    FCH
    CN
    CN
    UTP CTG5 ST CA-M
    TOPU
    PIM 1
    PIM 2
    PIM 3
    PIM 0
    LPM
    06 04 05 03 02 01 00
    06 04 05 03 02 01 00
    CN
    CN
    CN
    CN
    UTP CTG5 ST CA-J
    CNFCH
    HUB
    CN
    CNHUB
    BASEU
    PIM 1
    PIM 2
    PIM 3
    LPM
    CN
    FANU
    PIM 0UTP CTG5 CRS CA-F
    CNFCH
    CN
    UTP CTG5 ST CA-M
    UTP CTG5 ST CA-K
    BSCM
    TOPU
       
    FCH (PA-FCHA)HUB (PA-M96)
    TP0-X TP1-X
    TP2-X
    TP3-X TP4-X TP5-X TP6-X TP7-X
    10 BASE-T
    Connectors for 10 BASE-T
    FRONT VIEWFRONT VIEW
    CN= 10  BASE-T Connector
    Use 10 BASE-T connectors.  
    						
    							NDA-24299 CHAPTER 4
    Page 55
    Revision 1.0
    INSTALLATION
    Connecting Cables
    Figure 4-15   Examples of Ethernet Cable Connection-FCH in PIM2 (1-IMG System) (2/2)
    ATTENTIO NContents
    S ta tic S en s itive
    Handling
    Precautions Required
    06 04 05 03 02 01 00
    06 04 05 03 02 01 00
    CN
    CN
    CN
    CNCN
    CNUTP CTG5 ST CA-J
    CNFC H
    HUB
    CN
    HUB
    BASEU
    PIM 1
    PIM 2
    PIM  3
    LPM
    CN
    CN
    FANU
    PIM 0
    CN
    FCH
    CN
    UTP CTG5 ST CA-M
    UTP CTG5 ST CA-K
    UTP CTG5 ST CA-J
    TO PU
    06 04 05 03 02 01 0006 04 05 03 02 01 00
    CN
    CNCN
    CN
    HUB
    CN
    CNHUB
    BASEU
    PIM  1
    PIM 2
    PIM  3
    UTP CTG5 ST CA-J
    PIM 0
    LPMFANU
    BSCM BSCM
    CN
    FC H
    CN
    FCH
    CN
    CN
    UTP CTG5 ST CA-MUTP CTG5 ST CA-J
    TO PU
    < F C H  in P IM 2 (P attern 3)>   
    Note:When dual LANIs are used in both Slot 00 and 03 of CPR (Pattern 3 or 4), be sure to use at least 
    two HUB cards: One HUB for internal LANI (in Slot 00) and the other for external LANI (in Slot 
    03). However, if this is the case, and FCH is also in a dual configuration, the 10 BASE-T “cross” 
    connection between the HUBs is not required.  
    						