CHAPTER 3 ND-70290 (E)
Pag e 4 4
Revision 3.0
PA-4CSIC (CSINT)
PA-4CSIC (CSINT)  : ZT (Zone Transceiver) Interface
1. General Functions
This circuit card is designed to provide the ISDN S interface to the Zone Transceiver (ZT).
Specifications and functions of this circuit card are shown below.
 A maximum of four ZTs can be accommodated in one 4CSIC circuit card.
 Interface with ZTs is based on the ISDN standard interface, though the multi-point connection of the
ZTs is not available.
 I.430, Q.921...

Page 62

ND-70290 (E) CHAPTER 3
Page 45
Revision 3.0
PA-4CSIC (CSINT)
3. Lamp, Key, Connector and Their Location
The following diagram shows the location of Lamp, Key and Connectors.
Figure 3-2  Lamp, Key and Connectors : PA-4CSIC
OPE
MB
SW10
NOPE
MODE
SWL3
SWL2
SWL1
SWL0
L3
L2
L1
L0 BL34
BL33
BL32
BL31
LYR3
PWR3
BL24
BL23
BL22
BL21
LYR2
PWR2
BL14
BL13
BL12
BL11
LYR1
PWR1
SYNCBL04
BL03
BL02
BL01
LYR0
PWR0
SW12 SW11 

Page 63

CHAPTER 3 ND-70290 (E)
Pag e 4 6
Revision 3.0
PA-4CSIC (CSINT)
4. Lamp Indication
Shown below are the contents of lamp indication on this circuit card.
n=0~3
Note 1:B1 through B4 channels represent channel names of 32k ADPCM.
LAMP NAME COLOR MEANING
OPE Green Remains lit when this card is operating normally.
NOPE Red Remains lit when this card is in make-busy state.
BLn4 Green  Remains lit when B4 channel of the line #n is communicating  
Note 1
Flashing Flashes while the corresponding circuit is in...

Page 64

ND-70290 (E) CHAPTER 3
Page 47
Revision 3.0
PA-4CSIC (CSINT)
5. Switch Settings
Standard settings of switches on this circuit card are shown in the table below.
SWITCH NAMESWITCH 
NUMBERSWITCH 
SETTINGSTANDARD 
SETTINGMEANING
MB
 (Toggle Switch)
UpCircuit card make-busy set
Down
Circuit card make-busy cancel
MBR
 (Piano-Key Switch)
0ON Line 0 make-busy request
OFF×Line 0 make-busy request cancel
1ON Line 1 make-busy request
OFF×Line 1 make-busy request cancel
2ON Line 2 make-busy request
OFF×Line 2...

Page 65

CHAPTER 3 ND-70290 (E)
Pag e 4 8
Revision 3.0
PA-4CSIC (CSINT)
SWITCH NAMESWITCH 
NUMBERSWITCH 
SETTINGSTANDARD 
SETTINGMEANING
SW11 
1PAD on TSW side
2
3PAD on LINE side
4
5PB Sender Mode (Law/Level) Selection  
Note:µ/A-law can be selected on the TSW side PAD. 
µ-law Standard =High: -7.0 dBm 
Low: -9.0 dBm
A-law Standard =High: -8.0 dBm 
Low: -10.0 dBm 6
7ON×Fixed
8ON×Fixed
(DIP Switch)
ON
12
3456
78SWITCH 1 SWITCH 2 PADOFF OFF Not used
ON OFF A-Law
OFF ON µ (PS)-A (TSW) Conversion
ON ON µ-Law...

Page 66

ND-70290 (E) CHAPTER 3
Page 49
Revision 3.0
PA-4CSIC (CSINT)
Note 1:
The following diagram shows the PAD control method.
[Firmware: SW-329]
SWITCH NAMESWITCH 
NUMBERSWITCH 
SETTINGSTANDARD 
SETTINGMEANING
SW12
(DIP Switch)
1~3PAD control (PAD value of the TSW side)  
Note 1
4~6PAD control (PAD value of the line side)  
Note 1
7OFF×Fixed
8OFF×Fixed
ON
12
3456 78SWITCH 1 SWITCH 2 SWITCH 3 PAD VALUE OF THE TSW SIDEOFF OFF OFF Not used
ON OFF OFF PAD 2=0 dB, PAD 1=–5 dB
OFF ON OFF PAD 2=0 dB, PAD 1=–3 dB
ON...

Page 67

CHAPTER 3 ND-70290 (E)
Pag e 5 0
Revision 3.0
PA-4CSIC (CSINT)
Note 1:
The following diagram shows the PAD control method.
Note 2:Pad value of both PAD 1 and PAD 2 is 0 dB.
[Firmware: SW-359]
SWITCH NAMESWITCH 
NUMBERSWITCH 
SETTINGSTANDARD 
SETTINGMEANING
SW12
(DIP Switch)
1~8
ON
12
3456
78
Connection with C.O. if Echo Canceller is not effective. Note 1Connection with C.O. if Echo Canceller is effective. Note 2
SWITCH 1 SWITCH 2 SWITCH 3 PAD VALUE SWITCH 1 SWITCH 2 SWITCH 3 PAD VALUE
OFF OFF OFF Not...

Page 68

ND-70290 (E) CHAPTER 3
Page 51
Revision 3.0
PA-4CSIC (CSINT)
Note 1:
SWL0~SWL3 determines the cable length from CSINT to ZT, however the maximum length of each cable
varies according to the diameter of the cable.
Power supply from Built-in PCS system (Without arrestor, when feed output is 48V) 
Local power supply (With arrestor)
SWITCH NAMESWITCH 
NUMBERSWITCH 
SETTINGSTANDARD 
SETTINGMEANING
SWL0 
SWL1 
SWL2 
SWL3
(Rotary Switch)
Setting of the cable length to the 
corresponding ZT 
 Note 1 
SWL0:...

Page 69

CHAPTER 3 ND-70290 (E)
Pag e 5 2
Revision 3.0
PA-4CSIC (CSINT)
PA-4CSIC (CSINT) : ZT (Zone Transceiver) Interface
Table 3-1  Switch Setting Table
MODULE
NAMESLOTSWITCH 
NAMESWITCH SHAPE REMARKS
PIM MB ON : Make-busy set of circuit 
card 
OFF : Make-busy cancel of 
circuit card
MBR
MODE
SW10
SW11
SW12
SWL0
SWL1
SWL2
SWL3
ON (MB)
OFF
No. 3
No. 2
No. 1
No. 0OFF
ON
ON
12
34
ON
12
3456
78
ON
12
3456 78 

Page 70

ND-70290 (E) CHAPTER 3
Page 53
Revision 3.0
PA-4CSIC (CSINT)
6. External interface
Below are accommodation of the LT connector leads of this circuit card and connecting route diagram.
a. LT Connector Lead Accommodation when this circuit card is mounted in PIM.
Figure 3-3  LT Connector Leads Accommodation of PIM : PA-4CSIC
26272829303132333435363738394041
1234567891011121314151642434445464748
1718192021222349502425
Accommodated in *1
LT0, 2, 4, 6, 8, 10 Connector
LT Connector Accommodation...