Page 31

NEAX2400 IMX CCIS Features and Specifications
Page 16NDA-24222, Issue 3
A-126 ANI-CCIS (16 Digit)
A-126 ANI-CCIS (16 Digit)
General Description
This feature allows an office receiving ANI information from Central Office through an analog trunk (Caller ID or
MF) to extend to another office through CCIS when the tandem connection is established.
Operating Procedure
No manual operation is required.
Service Conditions
1. The maximum digits of ANI information sent to another office through CCIS are 16.
2....

Page 32

NEAX2400 IMX CCIS Features and Specifications
NDA-24222, Issue 3
Page 17
Busy Verification - CCIS B-9
B-9 Busy Verification - CCIS
General Description
This service feature allows Inter-Office Attendant BUSY VERIFICATION when the Attendant and the called party
respectively belong to a different PBX in the CCIS network.
Operating Procedure
1. Station (a) and (b) are in connection on a station-to-station call.
2. The Attendant in Node A presses the loop key; the loop lamp and DEST lamp on the Attendant...

Page 33

NEAX2400 IMX CCIS Features and Specifications
Page 18NDA-24222, Issue 3
B-9 Busy Verification - CCIS
Service Conditions (cont’d)
4. BUSY VERIFICATION cannot be established to a BUSY station when the station is: 
a.) Dialing
b.) Listening to a tone
c.) Being rung
d.) Protected by DATA LINE SECURITY [D-12] [D-66]
e.) Being connected to an BUSY VERIFICATION Loop
f.) Activating a conflicting feature, such as:
ATTENDANT CAMP-ON WITH TONE INDICATION [A-1][A-45] 
BOSS-SECRETARY OVERRIDE-D
term[B-5D] 
CALL HOLD...

Page 34

NEAX2400 IMX CCIS Features and Specifications
NDA-24222, Issue 3
Page 19
Busy Verification - CCIS B-9
Interactions (cont’d)
4. ATTENDANT LOCKOUT [A-5]: The Attendant is prevented from verifying a busy station line that is
connected to a loop held at the Attendant Console. Since the LOCKOUT feature applies only to calls held
on an Attendant Console loop, BUSY VERIFICATION - CCIS of those station lines will be denied, and
the Attendant will hear reorder tone.
5. CALL FORWARDING - CCIS (ALL CALLS [C-45],...

Page 35

NEAX2400 IMX CCIS Features and Specifications
Page 20NDA-24222, Issue 3
B-10 Brokerage Hotline - CCIS
B-10  Brokerage Hotline - CCIS 
General Description
This feature provides a hotline function between two stations at different nodes in the CCIS network, using a line/
feature key of a Dterm.
Operating Procedure
To access a BROKERAGE HOTLINE - CCIS from a Dterm:
1. Lift the handset or press the SPEAKER button. 
2. Press the line/feature key associated with a predetermined station in another office. The...

Page 36

NEAX2400 IMX CCIS Features and Specifications
NDA-24222, Issue 3
Page 21
Call Back - CCIS C-44
C-44  Call Back - CCIS 
General Description
This service feature allows an Inter-office Call Back when the calling station and the called station respectively
belong to a different PBX in the CCIS network. 
Operating Procedure
To set from a Single-Line Telephone:
1. Dial the desired telephone number; receive busy tone.
2. Switch hook flash; receive special dial tone.
3. Dial the CALL BACK - CCIS code; receive...

Page 37

NEAX2400 IMX CCIS Features and Specifications
Page 22NDA-24222, Issue 3
C-44 Call Back - CCIS
Operating Procedure (cont’d)
3. The LCD will display: 
Service Conditions 
1. If CALL BACK is not answered within 30 seconds, or the timer interval in ASYD index 139, ringing will
stop and the CALL BACK will automatically be cancelled.
2. CALL BACK to a busy station cannot be established if the station is in the LINE LOCKOUT [L-3] mode. 
3. There is no time limit for CALL BACK once activated. It will remain in...

Page 38

NEAX2400 IMX CCIS Features and Specifications
NDA-24222, Issue 3
Page 23
Call Back - CCIS C-44
Interactions 
1. OUTGOING TRUNK QUEUING [O-2] and CALL BACK - CCIS cannot be accessed simultaneously.
2. System Data 1, Index 139. No Answer Timer is also used for station-to-station call, DID, or TIE Line call
for CALL FORWARDING-DON’T ANSWER [C-47] and CALL HOLD [C-6].
3. CALL WAITING-ORIGINATE [C-31] automatic setting and CALL BACK - CCIS are mutually
exclusive.
4. CALL BACK - CCIS cannot be activated toward...

Page 39

NEAX2400 IMX CCIS Features and Specifications
Page 24NDA-24222, Issue 3
C-45 Call Forwarding - All Calls - CCIS
C-45  Call Forwarding - All Calls - CCIS
General Description
This service feature allows Inter-Office CALL FORWARDING-ALL CALLS when the transferring station and the
transferred station, respectively, belong to a different PBX in the CCIS network. 
Operating Procedure
When setting Call Forwarding-All Calls Service:
1. Station A goes off-hook; receives dial tone.
2. Station A dials the Access...

Page 40

NEAX2400 IMX CCIS Features and Specifications
NDA-24222, Issue 3
Page 25
Call Forwarding - All Calls - CCIS C-45
Operating Procedure (cont’d)
6. Station B answers; Stations B and C are connected with each other.
When cancelling Call Forwarding-All Calls Service:
1. Station A goes off-hook; receives dial tone.
2. Station A dials the Cancel Code of Call Forwarding-All Calls; receives service set tone.
3. Station A hangs up. 
Service Conditions
1. Stations with this feature set may originate calls and...