Home > NEC > Communications System > NEC Neax 2000 Ivs2 Data Interface System Manual

NEC Neax 2000 Ivs2 Data Interface System Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax 2000 Ivs2 Data Interface System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							CHAPTER 5 CIRCUIT CARD INFORMATION
    Mounting Location of Circuit Card
    NEAX2000 IVS2 Data Interface System Manual    
    ND-70924 (E), Issue 1.0   Page 65
    MOUNTING LOCATION OF CIRCUIT CARD
    This section explains the conditions for mounting circuit cards for the Data Interface.
    Figure 5-1 shows circuit card mounting slots allocated in the PIM.
    Figure 5-1  Mounting Location of Circuit Card
    *1PN-CP14 (MP) card on the MP12 slot on PIM0.
    *2PN-24DTA-C/PN-30DTC-A (DTI) card on the AP00-AP11 slots on PIM0-PIM7.
    *3PN-2DPCB (DPC) and PN-M03 (M03) card on the LT00-LT11 slots on PIM0-PIM7.
    *4PZ-M542/PZ-M557 (CONN) card on the LTC0-LTC3 connectors on the PIM which
    accommodates 30DTI card.
    LT09/AP09LT08/AP08LT07/AP07
    LT C 1LT C 0LT C 2
    BWB
    PIM
    0~7
    FRONTAC/DC
    PWR
    LT10/AP10LT00/AP00LT01/AP01LT02/AP02LT03/AP03LT04/AP04LT05/AP05LT06/AP06LT11/AP11/FP11MP12/FP12
    LT C 3
    DC/DC
    PWR
    PFTVM
    *2, 
    *3*1
    *4 
    						
    							 NEAX2000 IVS2 Data Interface System ManualPage 66  ND-70924 (E), Issue 1.0
    CHAPTER 5 CIRCUIT CARD INFORMATION
    List of Required Circuit Cards
    LIST OF REQUIRED CIRCUIT CARDS
    Table 5-1 shows the required circuit cards to be explained in this section.
    *MB = Make Busy
    Table 5-1  List of Required Circuit Cards
    NAME
    (FUNCTIONAL
    NAME)
    LAMP
    X: PROVIDED
    –: NOT
    PROVIDEDSWITCH
    X: PROVIDED
    –: NOT
    PROVIDEDEXTRACTION/
    INSERTION WITH 
    POWER ON
    X: ALLOWED
    : ALLOWED 
    AFTER MB*
    –: NOT ALLOWED
    REFERENCE
    PAGE
    PN-CP14 (MP) X X –Page 67
    PN-24DTA-C (DTI) X XPage 72
    PN-30DTC-A (DTI) X XPage 78
    PZ-M542 (CONN) – X XPage 84
    PZ-M557 (CONN) – X XPage 86
    PN-2DPCB (DPC) X X XPage 88
    PN-M03 (M03) X X XPage 92 
    						
    							CHAPTER 5 CIRCUIT CARD INFORMATION
    List of Required Circuit Cards
    NEAX2000 IVS2 Data Interface System Manual    
    ND-70924 (E), Issue 1.0   Page 67
    PN-CP14 (MP)
    Locations of Lamps, Switches, and Connectors
    CONN: To CONNR connector on PZ-M537 (EXPMEM)
    Lamp Indications
    LAMP 
    NAMECOLOR FUNCTION
    RUN Green Flashes at 120 IPM while this card is operating normally.
    CLK Green Remains lit while receiving clock signals to the PLO.
    SW3
    RUN
    SW1
    SW2
    CLK
    VR
    DK JACK CONNSW4
    JP0JP1
    RS1
    RS0 
    						
    							 NEAX2000 IVS2 Data Interface System ManualPage 68  ND-70924 (E), Issue 1.0
    CHAPTER 5 CIRCUIT CARD INFORMATION
    List of Required Circuit Cards
    Switch Settings
    NOTE 1:Set the groove on the switch to the desired position.
    NOTE 2:Only when executing “MP Program Download” in MATWorX, set the SW3 to 5-8.
    CAUTION
    When the operating power is being supplied to this circuit card, do not plug/unplug this circuit 
    card into/from its mounting slot.
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    SW3 (Rotary SW)
    NOTE 1
    0-FOn Line
    (Call processing is in progress)
    2Off Line (Call processing is stopped)
     I/O port: As per CM40 YY=08
    3Off Line (Call processing is stopped)
     I/O port: 9600bps (Fixed)
    5
    NOTE 2Off Line (Call processing is stopped)
     I/O port: 9600bps
    6
    NOTE 2Off Line (Call processing is stopped)
     I/O port: 19200bps
    7
    NOTE 2Off Line (Call processing is stopped)
     I/O port: 38400bps
    8
    NOTE 2Off Line (Call processing is stopped)
     I/O port: 57600bps
    B For clearing the office data
    CFor setting the resident system 
    program
    1, 4, 9
    A, D-FNot used
    (Continued)
    0
    0 
    						
    							CHAPTER 5 CIRCUIT CARD INFORMATION
    List of Required Circuit Cards
    NEAX2000 IVS2 Data Interface System Manual    
    ND-70924 (E), Issue 1.0   Page 69
    SWITCH NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    SW1 (Push SW) For initializing CPU
    SW2
    (Piano Key SW)1ON A-law (Australia)
    OFF µ-law (North America)
    2, 3Selection of PLO0 input
    (Phase Locked Oscillator)
     For clock receiver office:
     For clock source office:
    SW2-2
    SW2-3
    OFF OFF
    4ONWhen using RS1 port for built-in 
    MODEM
    OFF When using RS1 port for RS-232C
    (Continued)
    4 
    3 
    2 
    1 OFF
    ONSW2-2 SW2-3 FUNCTION
    OFF OFF 1.5 MHz clock
    [For PN-24DTA-C/PN-24PRTA]
    ON OFF 192 kHz clock
    [For PN-BRTA]
    OFF ON 2 MHz clock
    [For PN-30DTC-A/PN-2BRTC]
    ON ON Not used 
    						
    							 NEAX2000 IVS2 Data Interface System ManualPage 70  ND-70924 (E), Issue 1.0
    CHAPTER 5 CIRCUIT CARD INFORMATION
    List of Required Circuit Cards
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIO
    NFUNCTION CHECK
    SW4 (Dip SW)
    1Not used
    2Not used
    3, 4Selection of PLO1 input
    (Phase Locked Oscillator)
     For clock receiver office:
     For clock source office:
    SW4-3
    SW4-4
    OFF OFF
    VR (Rotary SW) Variable Resister for External Hold 
    Tone Source
    (0 - 20 Kohms : Clockwise)
    DK (Connector)
    02 Ground detection
    01 Ground sending
    (Continued)
    1
    23
    4ON
    OFF
    OFF
    SW4-3 SW4-4 FUNCTION
    OFF OFF 1.5 MHz clock
    [For PN-24DTA-C/PN-24PRTA]
    ON OFF 192 kHz clock
    [For PN-BRTA]
    OFF ON 2 MHz clock
    [For PN-30DTC-A/PN-2BRTC]
    ON ON Not used
    20
    0
    01 02 
    						
    							CHAPTER 5 CIRCUIT CARD INFORMATION
    List of Required Circuit Cards
    NEAX2000 IVS2 Data Interface System Manual    
    ND-70924 (E), Issue 1.0   Page 71
    The figure in the SWITCH NAME column and the position in   in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the
    figure and  , the setting of the switch varies with the system concerned.
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    JP0 (Jumper pin)
    UPNot used
    (Memory backup OFF)
    For normal operation
    (Memory backup ON)
    JP1 (Jumper pin)
    For using internal tone source
    DOWN For using external tone source
    Fr o n tDOWN
    Fr o n t
    UP 
    						
    							 NEAX2000 IVS2 Data Interface System ManualPage 72  ND-70924 (E), Issue 1.0
    CHAPTER 5 CIRCUIT CARD INFORMATION
    List of Required Circuit Cards
    PN-24DTA-C (DTI)
    Locations of Lamps, Switches and Connectors
    SENSE
    RUN
    MB
     
     
    CRC 
    PCM 
    FRM 
    RMT 
    AIS 
    BL 
       
     
     
     
     
     
      SW1
    SW0
    JRR1
    AISS MAS
    JPR0
    JPS 
    						
    							CHAPTER 5 CIRCUIT CARD INFORMATION
    List of Required Circuit Cards
    NEAX2000 IVS2 Data Interface System Manual    
    ND-70924 (E), Issue 1.0   Page 73
    Lamp Indications
    LAMP 
    NAMECOLOR FUNCTION
    RUN Green Flashes at 120 IPM while this card is operating normally.
    CRC Red Remains lit when detecting Cyclic Redundancy Checking (CRC) 
    errors.
    PCM Red Remains lit when detecting PCM signal loss.
    FRM Red Remains lit when detecting Frame Alignment signal loss.
    RMT Red Remains lit when receiving Frame Alignment signal loss alarm 
    from a distant office.
    AIS Red Remains lit when a pattern of consecutive “1” is received. The 
    distant office transmits this signal for a loop-back test.
    BL Red B channel status
    ON : More than 10 channels are busy
    OFF : All channels are idle
    Flash (60 IPM) : Only one channel is busy
    Flash (120 IPM) : 2 through 10 channels are busy 
    						
    							 NEAX2000 IVS2 Data Interface System ManualPage 74  ND-70924 (E), Issue 1.0
    CHAPTER 5 CIRCUIT CARD INFORMATION
    List of Required Circuit Cards
    Switch Settings
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    SENSE
    (Rotary SW)
    NOTE 10-3 Not used
    4-F Set the switch to match the AP Number (04-31) to 
    be set by CM05.
    MB (Toggle SW)
    NOTE 2UP For make-busy
    For normal operation
    (Continued)
    F
    4
    AP No.SW1-4: ON04 05 06 07 08 09 10 11 12 13 14 15
    SW1-4: OFF20 21 22 23 24 25 26 27 28 29 30 31
    SW No.456789ABCDEF
    ON
    DOWN 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax 2000 Ivs2 Data Interface System Manual