Home > NEC > Communications System > NEC Neax 2000 Ivs2 Data Interface System Manual

NEC Neax 2000 Ivs2 Data Interface System Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax 2000 Ivs2 Data Interface System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							ND-70924 (E)
    ISSUE 1
    STOCK # 151993
    Data Interface System Manual
    ®
    JULY, 2000
    NEC America, Inc. 
    						
    							LIABILITY DISCLAIMER
    NEC America, Inc. reserves the right to change the specifications,
    functions, or features, at any time, without notice.
    NEC America, Inc. has prepared this document for use by its
    employees and customers. The information contained herein is
    the property of NEC America, Inc. and shall not be reproduced
    without prior written approval from NEC America, Inc.
    NEAX and D
    term are registered trademarks of NEC Corporation. 
    Copyright 2000
    NEC America, Inc.
    Printed in U.S.A. 
    						
    							ISSUE 1 ISSUE 2 ISSUE 3 ISSUE 4
    DAT E JULY,  20 00 DATE DAT E DAT E
    ISSUE 5 ISSUE 6 ISSUE 7 ISSUE 8
    DAT E DATE DAT E DAT E
    NEAX2000 IVS2
    Data Interface System ManualRevision Sheet 1/2
    ND-70924 (E)
    PA G E  N o .ISSUE No.12345678
    i1
    ii1
    iii1
    iv
    1
    11
    21
    31
    4
    1
    51
    61
    71
    8
    1
    91
    101
    111
    12
    1
    131
    141
    151
    16
    1
    171
    181
    191
    20
    1
    211
    221
    231
    24
    1
    251
    261
    271
    28
    1
    291
    301
    311
    32
    1
    331
    341
    351
    36
    1
    371
    381
    391
    40
    1
    411
    421
    431
    44
    1
    451
    461
    471
    48
    1
    491
    501
    511
    52
    1
    531
    541
    551
    56
    1
    571
    581
    591
    60
    1
    611
    621
    631
    64
    1
    651
    661
    671
    68
    1
    691
    701
    711
    72
    1 PA G E  N o .ISSUE No.
    12345678 
    						
    							ISSUE 1 ISSUE 2 ISSUE 3 ISSUE 4
    DAT E JULY,  20 00 DATE DAT E DAT E
    ISSUE 5 ISSUE 6 ISSUE 7 ISSUE 8
    DAT E DATE DAT E DAT E
    NEAX2000 IVS2
    Data Interface System ManualRevision Sheet 2/2
    ND-70924 (E)
    731
    741
    751
    76
    1
    771
    781
    791
    80
    1
    811
    821
    831
    84
    1
    851
    861
    871
    88
    1
    891
    901
    911
    92
    1
    931
    941
    PA G E  N o .ISSUE No.12345678PA G E  N o .ISSUE No.12345678 
    						
    							NEAX2000 IVS2 Data Interface System Manual    
    ND-70924 (E), Issue 1.0   Page i
    NEAX2000 IVS2
    Data Interface System Manual
    TABLE OF CONTENTS
    Page
    LIST OF FIGURES  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
    LIST OF TABLES  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv
    INTRODUCTION   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .    1
    PURPOSE  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  . .  1
    OUTLINE OF THIS MANUAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1
    REFERENCE MANUAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
    CHAPTER 1 GENERAL INFORMATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   3
    SYSTEM OUTLINE  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4
    DPC  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  . . . .  7
    DTI  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  . . . . .  7
    M03   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  . . . .  7
    PLO   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  . . . .  8
    CARD NAME AND FUNCTION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  9
    SYSTEM CAPACITY  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11
    System Capacity for Data Interface  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11
    System Capacity for Digital Trunk Interface   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11
    SYSTEM SPECIFICATIONS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12
    DPC Specifications   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12
    Modem Specifications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
    SYSTEM CONDITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
    Time Slot Assignment Condition   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  13
    Time Slot Allocation for DTI Card   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  14
    CHAPTER 2 INSTALLATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   15
    PRECAUTIONS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  16
    Static Electricity Guard   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  16
    REQUIRED EQUIPMENT  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  19
    INSTALLATION PROCEDURE FOR DATA INTERFACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  20
    Installation Summary for Data Interface   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  20
    Mounting DPC Card  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
    Mounting M03 Card  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
    Conditions on Connecting DTE  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  22
    Connecting X.21 DTE   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
    Connecting V.24/V.28 DTE  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  28
    Connecting RS-449 DTE  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  31
    Connecting V.35 DTE   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
    Installation Procedure for Digital Trunk Interface  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  38
    Installation Summary for Digital Trunk Interface   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  38
    Mounting DTI Card   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  39 
    						
    							 NEAX2000 IVS2 Data Interface System ManualPage ii  ND-70924 (E), Issue 1.0
    TABLE OF CONTENTS
    Page
    Mounting CONN Card   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
    DTI Cable Connection via MDF  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  40
    DTI Cable Connection via CONN Card  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  43
    CHAPTER 3 SYSTEM DATA PROGRAMMING  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   45
    HOW TO READ THIS CHAPTER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  46
    DATA INTERFACE ASSIGNMENT  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  47
    DIGITAL TRUNK INTERFACE ASSIGNMENT  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  50
    CHAPTER 4 OPERATION TEST  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   55
    DPC LOOPBACK TEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
    DPC Loopback 1 Test  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
    DPC Loopback 2 Test  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
    OTHER LOOPBACK TESTS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  60
    INTER-OFFICE DIGITAL DATA TRANSMISSION TEST  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  61
    CHAPTER 5 CIRCUIT CARD INFORMATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   63
    HOW TO READ THIS CHAPTER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  64
    MOUNTING LOCATION OF CIRCUIT CARD  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  65
    LIST OF REQUIRED CIRCUIT CARDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  66
    PN-CP14 (MP)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  67
    PN-24DTA-C (DTI)   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
    PN-30DTC-A (DTI)   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
    PZ-M542 (CONN)   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
    PZ-M557 (CONN)   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
    PN-2DPCB (DPC)   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
    PN-M03 (M03)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  92 
    						
    							LIST OF FIGURES
    Figure TitlePage
    NEAX2000 IVS2 Data Interface System Manual    
    ND-70924 (E), Issue 1.0   Page iii
    Figure 1-1 System Outline of Intra-Office Data Connection  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4
    Figure 1-2 System Outline of Inter-Office Data Connection   . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  6
    Figure 1-3 Clock Supply Route  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8
    Figure 1-4 Accommodation of DTI into TDSW   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  13
    Figure 1-5 Time Slot Allocation for DTI  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
    Figure 2-1 Static Electricity Guard (1 of 2)   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
    Figure 2-1  Static Electricity Guard (2 of 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
    Figure 2-2 Installation Procedure for Data Interface  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  20
    Figure 2-3 Limitation on Using Modem  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  22
    Figure 2-4 Cable Connection between DPC Card and X.21 DTE/Modem  . . . . . . . . . . . . . . . . . .  23
    Figure 2-5 Cable Connection between DPC Card and X.21 DTE/Modem  . . . . . . . . . . . . . . . . . .  25
    Figure 2-6 DPC V11 Cable  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  27
    Figure 2-7 Cable Connection between DPC Card and V.24/V.28 DTE/Modem  . . . . . . . . . . . . . .  28
    Figure 2-8 Cable Connection between DPC Card and V.24/V.28 DTE/Modem  . . . . . . . . . . . . . .  29
    Figure 2-9 DPC RS Cable  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  30
    Figure 2-10 Cable Connection between DPC Card and RS-449 DTE   . . . . . . . . . . . . . . . . . . . . . .  31
    Figure 2-11 RS-449 Connector Pin Assignments  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  32
    Figure 2-12 X.21 Connector Pin Assignments   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  32
    Figure 2-13 Outline of V.35 Cable Connection  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  33
    Figure 2-14 Cable Connection between M03 Card and V.35 DTE/Modem   . . . . . . . . . . . . . . . . . .  34
    Figure 2-15 Cable Connection between M03 Card and V.35 DTE/Modem   . . . . . . . . . . . . . . . . . .  35
    Figure 2-16 DPC V35 Cable  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  36
    Figure 2-17 V.35 Connector Pin Assignment   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  37
    Figure 2-18 Installation Procedure for DTI   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
    Figure 2-19 DTI Cable Connection via MDF  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  40
    Figure 2-20 Location of the AP Slots and the LTC Connectors for DTI   . . . . . . . . . . . . . . . . . . . . .  41
    Figure 2-21 Example of MDF Cross Connection for DTI   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  42
    Figure 2-22 DTI Cable Connection via CONN Card  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  43
    Figure 2-23 Example of Coaxial Cable Connection   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  44
    Figure 4-1 DPC Loopback Tests  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
    Figure 4-2 Connection of Modem Tester   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  57
    Figure 4-3 Other Loopback Tests  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
    Figure 4-4 Inter-Office Digital Data Transmission Test  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  61
    Figure 5-1 Mounting Location of Circuit Card  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  65 
    						
    							 NEAX2000 IVS2 Data Interface System ManualPage iv  ND-70924 (E), Issue 1.0
    LIST OF TABLES
    Table TitlePage
    Table 1-1 Connecting Patterns   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
    Table 1-2 Card Name and Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  9
    Table 1-3 System Capacity for Data Interface  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11
    Table 1-4 System Capacity for Digital Trunk Interface   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11
    Table 1-5 DPC Specifications   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12
    Table 1-6 Rate Adaptation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12
    Table 1-7 Modem Specifications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
    Table 2-1 Required Equipment   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
    Table 2-2 X.21 to RS-449 Adapter Cable Connections  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  31
    Table 2-3 V.35 Interface Cable Connector Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . .  37
    Table 5-1 List of Required Circuit Cards   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  66 
    						
    							INTRODUCTION
    Purpose
    NEAX2000 IVS2 Data Interface System Manual   ND-70924 (E), Issue 1.0  Page 1
    INTRODUCTION
    PURPOSE
    This manual explains the installation, programming and operation test procedure for the Data
    Interface system on the NEAX2000 IVS
    2.
    OUTLINE OF THIS MANUAL
    This manual contains the following chapters:
    CHAPTER 1 GENERAL INFORMATION
    This chapter explains the system outline, the name and functions of circuit cards required,
    system capacity, system specifications and system conditions of Data Interface system.
    CHAPTER 2 INSTALLATION
    This chapter explains the hardware installation procedure to provide Data Interface on the PBX.
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    This chapter explains the programming procedure to provide the Data Interface on the PBX.
    CHAPTER 4 OPERATION TEST
    This chapter explains the operation tests to be performed after completing the installation of the
    Data Interface on the PBX.
    CHAPTER 5 CIRCUIT CARD INFORMATION
    This chapter explains the mounting location, the meaning of lamp indications, and the method of
    switch settings of each circuit card for the Data Interface. 
    						
    							 NEAX2000 IVS2 Data Interface System ManualPage 2  ND-70924 (E), Issue 1.0
    INTRODUCTION
    Reference Manual
    REFERENCE MANUAL
    During installation, refer also to the manuals below:
    Command Manual: Describes Customer Administration Terminal (CAT)
    operation, command function and setting data required for
    programming the system, and Resident System Program.
    Office Data Programming Manual: Contains the Customer Specification Sheet and Office Data
    Programming Sheet.
    Maintenance Manual: Describes the maintenance service features and the
    recommended troubleshooting procedure.
    Installation Procedure Manual: Explains the installation procedure for the PBX system. 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax 2000 Ivs2 Data Interface System Manual