ND-70924 (E) ISSUE 1 STOCK # 151993 Data Interface System Manual ® JULY, 2000 NEC America, Inc.
LIABILITY DISCLAIMER NEC America, Inc. reserves the right to change the specifications, functions, or features, at any time, without notice. NEC America, Inc. has prepared this document for use by its employees and customers. The information contained herein is the property of NEC America, Inc. and shall not be reproduced without prior written approval from NEC America, Inc. NEAX and D term are registered trademarks of NEC Corporation. Copyright 2000 NEC America, Inc. Printed in U.S.A.
ISSUE 1 ISSUE 2 ISSUE 3 ISSUE 4 DAT E JULY, 20 00 DATE DAT E DAT E ISSUE 5 ISSUE 6 ISSUE 7 ISSUE 8 DAT E DATE DAT E DAT E NEAX2000 IVS2 Data Interface System ManualRevision Sheet 1/2 ND-70924 (E) PA G E N o .ISSUE No.12345678 i1 ii1 iii1 iv 1 11 21 31 4 1 51 61 71 8 1 91 101 111 12 1 131 141 151 16 1 171 181 191 20 1 211 221 231 24 1 251 261 271 28 1 291 301 311 32 1 331 341 351 36 1 371 381 391 40 1 411 421 431 44 1 451 461 471 48 1 491 501 511 52 1 531 541 551 56 1 571 581 591 60 1 611 621 631 64 1 651 661 671 68 1 691 701 711 72 1 PA G E N o .ISSUE No. 12345678
ISSUE 1 ISSUE 2 ISSUE 3 ISSUE 4 DAT E JULY, 20 00 DATE DAT E DAT E ISSUE 5 ISSUE 6 ISSUE 7 ISSUE 8 DAT E DATE DAT E DAT E NEAX2000 IVS2 Data Interface System ManualRevision Sheet 2/2 ND-70924 (E) 731 741 751 76 1 771 781 791 80 1 811 821 831 84 1 851 861 871 88 1 891 901 911 92 1 931 941 PA G E N o .ISSUE No.12345678PA G E N o .ISSUE No.12345678
NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page i NEAX2000 IVS2 Data Interface System Manual TABLE OF CONTENTS Page LIST OF FIGURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii LIST OF TABLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 PURPOSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 OUTLINE OF THIS MANUAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 REFERENCE MANUAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 CHAPTER 1 GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 SYSTEM OUTLINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 DPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 DTI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 M03 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 PLO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 CARD NAME AND FUNCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 SYSTEM CAPACITY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 System Capacity for Data Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 System Capacity for Digital Trunk Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 SYSTEM SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 DPC Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Modem Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 SYSTEM CONDITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Time Slot Assignment Condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Time Slot Allocation for DTI Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 CHAPTER 2 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Static Electricity Guard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 REQUIRED EQUIPMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 INSTALLATION PROCEDURE FOR DATA INTERFACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Installation Summary for Data Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Mounting DPC Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Mounting M03 Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Conditions on Connecting DTE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Connecting X.21 DTE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Connecting V.24/V.28 DTE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Connecting RS-449 DTE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Connecting V.35 DTE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Installation Procedure for Digital Trunk Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Installation Summary for Digital Trunk Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Mounting DTI Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
NEAX2000 IVS2 Data Interface System ManualPage ii ND-70924 (E), Issue 1.0 TABLE OF CONTENTS Page Mounting CONN Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 DTI Cable Connection via MDF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 DTI Cable Connection via CONN Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 CHAPTER 3 SYSTEM DATA PROGRAMMING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 HOW TO READ THIS CHAPTER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 DATA INTERFACE ASSIGNMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 DIGITAL TRUNK INTERFACE ASSIGNMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 CHAPTER 4 OPERATION TEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 DPC LOOPBACK TEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 DPC Loopback 1 Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 DPC Loopback 2 Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 OTHER LOOPBACK TESTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 INTER-OFFICE DIGITAL DATA TRANSMISSION TEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 CHAPTER 5 CIRCUIT CARD INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 HOW TO READ THIS CHAPTER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 MOUNTING LOCATION OF CIRCUIT CARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 LIST OF REQUIRED CIRCUIT CARDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 PN-CP14 (MP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 PN-24DTA-C (DTI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 PN-30DTC-A (DTI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 PZ-M542 (CONN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 PZ-M557 (CONN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 PN-2DPCB (DPC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 PN-M03 (M03) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
LIST OF FIGURES Figure TitlePage NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page iii Figure 1-1 System Outline of Intra-Office Data Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Figure 1-2 System Outline of Inter-Office Data Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Figure 1-3 Clock Supply Route . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Figure 1-4 Accommodation of DTI into TDSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Figure 1-5 Time Slot Allocation for DTI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Figure 2-1 Static Electricity Guard (1 of 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Figure 2-1 Static Electricity Guard (2 of 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 Figure 2-2 Installation Procedure for Data Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Figure 2-3 Limitation on Using Modem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Figure 2-4 Cable Connection between DPC Card and X.21 DTE/Modem . . . . . . . . . . . . . . . . . . 23 Figure 2-5 Cable Connection between DPC Card and X.21 DTE/Modem . . . . . . . . . . . . . . . . . . 25 Figure 2-6 DPC V11 Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Figure 2-7 Cable Connection between DPC Card and V.24/V.28 DTE/Modem . . . . . . . . . . . . . . 28 Figure 2-8 Cable Connection between DPC Card and V.24/V.28 DTE/Modem . . . . . . . . . . . . . . 29 Figure 2-9 DPC RS Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Figure 2-10 Cable Connection between DPC Card and RS-449 DTE . . . . . . . . . . . . . . . . . . . . . . 31 Figure 2-11 RS-449 Connector Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Figure 2-12 X.21 Connector Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Figure 2-13 Outline of V.35 Cable Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Figure 2-14 Cable Connection between M03 Card and V.35 DTE/Modem . . . . . . . . . . . . . . . . . . 34 Figure 2-15 Cable Connection between M03 Card and V.35 DTE/Modem . . . . . . . . . . . . . . . . . . 35 Figure 2-16 DPC V35 Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Figure 2-17 V.35 Connector Pin Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Figure 2-18 Installation Procedure for DTI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Figure 2-19 DTI Cable Connection via MDF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Figure 2-20 Location of the AP Slots and the LTC Connectors for DTI . . . . . . . . . . . . . . . . . . . . . 41 Figure 2-21 Example of MDF Cross Connection for DTI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Figure 2-22 DTI Cable Connection via CONN Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Figure 2-23 Example of Coaxial Cable Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Figure 4-1 DPC Loopback Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Figure 4-2 Connection of Modem Tester . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 Figure 4-3 Other Loopback Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Figure 4-4 Inter-Office Digital Data Transmission Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 Figure 5-1 Mounting Location of Circuit Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
NEAX2000 IVS2 Data Interface System ManualPage iv ND-70924 (E), Issue 1.0 LIST OF TABLES Table TitlePage Table 1-1 Connecting Patterns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Table 1-2 Card Name and Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Table 1-3 System Capacity for Data Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Table 1-4 System Capacity for Digital Trunk Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Table 1-5 DPC Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Table 1-6 Rate Adaptation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Table 1-7 Modem Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Table 2-1 Required Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Table 2-2 X.21 to RS-449 Adapter Cable Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Table 2-3 V.35 Interface Cable Connector Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Table 5-1 List of Required Circuit Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
INTRODUCTION Purpose NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 1 INTRODUCTION PURPOSE This manual explains the installation, programming and operation test procedure for the Data Interface system on the NEAX2000 IVS 2. OUTLINE OF THIS MANUAL This manual contains the following chapters: CHAPTER 1 GENERAL INFORMATION This chapter explains the system outline, the name and functions of circuit cards required, system capacity, system specifications and system conditions of Data Interface system. CHAPTER 2 INSTALLATION This chapter explains the hardware installation procedure to provide Data Interface on the PBX. CHAPTER 3 SYSTEM DATA PROGRAMMING This chapter explains the programming procedure to provide the Data Interface on the PBX. CHAPTER 4 OPERATION TEST This chapter explains the operation tests to be performed after completing the installation of the Data Interface on the PBX. CHAPTER 5 CIRCUIT CARD INFORMATION This chapter explains the mounting location, the meaning of lamp indications, and the method of switch settings of each circuit card for the Data Interface.
NEAX2000 IVS2 Data Interface System ManualPage 2 ND-70924 (E), Issue 1.0 INTRODUCTION Reference Manual REFERENCE MANUAL During installation, refer also to the manuals below: Command Manual: Describes Customer Administration Terminal (CAT) operation, command function and setting data required for programming the system, and Resident System Program. Office Data Programming Manual: Contains the Customer Specification Sheet and Office Data Programming Sheet. Maintenance Manual: Describes the maintenance service features and the recommended troubleshooting procedure. Installation Procedure Manual: Explains the installation procedure for the PBX system.