CHAPTER 2 INSTALLATION Installation Procedure for Data Interface NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 33 Connecting V.35 DTE (1) Connect the M03 card and the DPC card as shown in Figure 2-13. (2) Connect the V.35 DTE/modem to the M03 card in the following pages. Figure 2-13 Outline of V.35 Cable Connection DPC V. 3 5 DTE/ 17-TW-0.3 CONN CABLE DPC V35 CABLE M03 PBX V.35 INTERFACE CABLE MODEM XCN0/XCN1 CONNECTOR X21 CONNECTOR V35 CONNECTOR (LOCALLY PROVICED)
NEAX2000 IVS2 Data Interface System ManualPage 34 ND-70924 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation Procedure for Data Interface Figure 2-14 Cable Connection between M03 Card and V.35 DTE/Modem NOTE:When you provide V.35 DTE using TXC(1) signal, this connection is required. (Continued) V35 CONNECTOR STRAIGHT CABLE (LOCALLY PROVIDED) M03 V. 3 5 DTE (J) (J) (P) (P) 4 m (13.1 ft.) MAX 15 m (49.2 ft.) TXD 4A 4B RXD 2A 2B RTS 6A CTS 6B DSR 5A GND 6D DCD 5B TXC(2) 3A 3B RXC 1C 2D DTR 5C TXC(1) 3C 4D TXD P S RXD R T RT S C CTS D DSR E GND B GND A DCD F TXC(2) Y AA RXC V X DTR H TXC(1) U WTXD P S RXD R T RTS C CTS D DSR E GND B GND A DCD F TXC(2) Y AA RXC V X DTR H TXC(1) U W NOTE DPC V35 CABLE Page 36 (1) Direct Connection
CHAPTER 2 INSTALLATION Installation Procedure for Data Interface NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 35 Figure 2-15 Cable Connection between M03 Card and V.35 DTE/Modem V35 CONNECTOR REVERSE CABLE (LOCALLY PROVIDED) M03 V.35 MODEM (J) (J) (P) (P) 4 m (13.1 ft.) MAX 15 m (49.2 ft.) TXD 4A 4B RXD 2A 2B RTS 6A CTS 6B DSR 5A GND 6D DCD 5B TXC(2) 3A 3B RXC 1C 2D DTR 5C TXC(1) 3C 4D TXD P S RXD R T RT S C CTS D DSR E GND B GND A DCD F TXC(2) Y AA RXC V X DTR H TXC(1) U WTXD P S RXD R T RTS C CTS D DSR E GND B GND A DCD F TXC(2) Y AA RXC V X DTR H TXC(1) U W (2) Modem Connection DPC V35 CABLE Page 36
NEAX2000 IVS2 Data Interface System ManualPage 36 ND-70924 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation Procedure for Data Interface Figure 2-16 DPC V35 Cable DA (J)(J) 1 6B NN 6D-GND 2A-RXDA 2B-RXDB 4A-TXDA 4B-TXDB 6A-RTS 6B-CTS 3C-TXC(1)A 4D-TXC(1)B 3A-TXC(2)A 3B-TXC(2)B 5A-DSR 5B-DCD 1C-RXCA 6 5 4 3 2 1RTS DSR TXDA TXC(2)A RXDA GA CTS DCD TXDB TXC(2)B RXDBB DTR TXC(1)A RXCAC GND TXC(1)B RXCBD X: NOT CONNECTED G: GROUND 2D-RXCB 5C-DTR 1A-GNDB-GND R-RXDA T-RXDB P-TXDA S-TXDB C-RTS D-CTS U-TXC(1)A W-TXC(1)B Y-TXC(2)A AA-TXC(2)B E-DSR F-DCD Y-RXCA X-RXCB H-DTR A-GND BGND F DCD LX RRXDA VRXCA ZX DD X JJ X NN XDCTS JX NX TRXDB XRXCB BB X FF X LL XAGND EDSR KX PTXDA U TXC(1)A Y TXC(2)A CC X HH X MM XCRTS HDTR MX STXDB W TXC(1)B AA TXC(2)B EE X KK X
CHAPTER 2 INSTALLATION Installation Procedure for Data Interface NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 37 Figure 2-17 V.35 Connector Pin Assignment Table 2-3 V.35 Interface Cable Connector Pin Assignments Pin Name Function Specification Source A B C D E F HGND GND RTS CTS DSR RLSD DTRFrame Ground Signal Ground Request To Send Clear To Send Data Set Ready Received Line Signal Detector Data Terminal Ready— — RS-232 RS-232 RS-232 RS-232 RS-232— — DTE DCE DCE DCE DTE P STXD Send Data V.35 DTE R TRXD Receive Data V.35 DCE U WSCTE Serial Clock Transmit External (A) Serial Clock Transmit External (B)V.35 DTE V XSCR Serial Clock Receive (A) Serial Clock Receive (B)V.35 DCE Y AA (or aa)SCT Serial Clock Transmit (A) Serial Clock Transmit (B)V.35 DCE L, M, N, Z, BB, CC, DD, EE, HH, JJ, KK, LL, MM, NNReserved for future V.35 use B F R V D T X Signal Pin Chassis Ground A Request To Send C Data Set Ready E Data Terminal Ready H Transmitted Data P Transmitted Data S Transmit Timing U Transmit Timing W Transmit Timing Y Transmit Timing AAPin Signal B Signal Ground D Clear To Send F Receive Line Signal Detect R Received Data T Received Data V Receive Timing X Receive Timing A E P U Y C H S W AA
NEAX2000 IVS2 Data Interface System ManualPage 38 ND-70924 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation Procedure for Data Interface INSTALLATION PROCEDURE FOR DIGITAL TRUNK INTERFACE Installation Summary for Digital Trunk Interface Install the equipment according to the procedure shown in Figure 2-18. Figure 2-18 Installation Procedure for DTI NOTE:This procedure is required when you provide CONN card to connect a coaxial cable for 30DTI. START Selection of PLO in MP Card Mounting DTI Card DTI Cable Connection Page 39 CHAPTER 5 Page 63 Page 40 via MDF Mounting CONN CardPage 39 NOTE END DTI Cable ConnectionPage 43 NOTEvia CONN Card
CHAPTER 2 INSTALLATION Installation Procedure for Data Interface NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 39 Mounting DTI Card (1) Before mounting the DTI (PN-24DTA-C/PN-30DTC-A) card, set the MB switch to UP position, and set the other switches to appropriate position. See CHAPTER 5.Page 63 (2) Mount the DTI card in the following AP slots on PIM0-PIM7. PIM0: AP00-AP10 slots PIM1-7: AP00-AP11 slots After mounting the card, set the MB to DOWN position to put the card in service. NOTE:The DTI card (DTI 0, DTI 1) which sends a clock signal to PLO of the MP card must be mounted in the AP slots on PIM0. Mounting CONN Card When you provide CONN (PZ-M542/M557) card to connect a coaxial cable for 30DTI, do the following installation. (1) Confirm the correct switch settings of the CONN card. See CHAPTER 5.Page 63 (2) Mount the CONN card on LTC connector on BWB in the PIM which accomodates the DTI cards. For details, refer to the Installation Procedure Manual. ATTENTIONContents Static Sensitive Handling Precautions Required
NEAX2000 IVS2 Data Interface System ManualPage 40 ND-70924 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation Procedure for Data Interface DTI Cable Connection via MDF When you use a twisted-pair cable, connect the cable to a CSU via the MDF as shown below. Location of AP Slots and LTC Connectors for DTI - Page 41 Example of MDF Cross Connection for DTI - Page 42 Figure 2-19 DTI Cable Connection via MDF CSU MDF LTC0/LTC1/LTC2/LTC3 CONNECTORTWISTED-PAIR CABLE BWBPBX (PIM0-PIM7) MAX. 200 m (655 ft.) Figure 2-20, Figure 2-21, Figure 2-22, Figure 2-23 (SHIELD TYPE) DTI
CHAPTER 2 INSTALLATION Installation Procedure for Data Interface NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 41 Figure 2-20 Location of the AP Slots and the LTC Connectors for DTI LTC0 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25RA TA RA TA RA TA MJ RB TB RB TB RB TB MNRA TA RA TA RA TA RB TB RB TB RB TBRA TA RA TA RA TA RB TB RB TB RB TBRA TA RA TA RA TA RB TB RB TB RB TB 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 AP00 SLOT AP01 SLOT AP02 SLOT LTC1 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 2526 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 AP03 SLOT AP04 SLOT AP05 SLOT LTC2 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 2526 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 AP08 SLOT AP07 SLOT AP06 SLOT AP11 SLOT AP10 SLOT AP09 SLOT LTC3 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 2526 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 L T 1 1 / A P 1 1 L T 1 0 / A P 1 0 L T 0 9 / A P 0 9 L T 0 8 / A P 0 8 L T 0 7 / A P 0 7 L T 0 6 / A P 0 6 L T 0 5 / A P 0 5 L T 0 4 / A P 0 4 L T 0 3 / A P 0 3 L T 0 2 / A P 0 2 L T 0 1 / A P 0 1 L T 0 0 / A P 0 0
NEAX2000 IVS2 Data Interface System ManualPage 42 ND-70924 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation Procedure for Data Interface Figure 2-21 Example of MDF Cross Connection for DTI 17 18 19 20RA TA42 43 44 45RB TB LTC1 (J)42 43 44 45RB TB17 18 19 20RA TA LTC1 (P) PIM 0 JP MDF DTI AP05 RA RB TA TB17 42 18 4317 42 18 43RA RB TA TBTO CSU LTC1 RECEIVE TRANSMIT