    							CHAPTER 2 INSTALLATION
    Installation Procedure for Data Interface
    NEAX2000 IVS2 Data Interface System Manual    
    ND-70924 (E), Issue 1.0   Page 33
    Connecting V.35 DTE
    (1) Connect the M03 card and the DPC card as shown in Figure 2-13.
    (2) Connect the V.35 DTE/modem to the M03 card in the following pages.
    Figure 2-13  Outline of V.35 Cable Connection
    DPC
    V. 3 5
    DTE/
    17-TW-0.3 CONN CABLE
    DPC V35 CABLE
    M03
    PBX
    V.35 INTERFACE CABLE
    MODEM
    XCN0/XCN1 CONNECTOR
    X21 CONNECTOR
    V35 CONNECTOR
    (LOCALLY PROVICED) 
    						
    							 NEAX2000 IVS2 Data Interface System ManualPage 34  ND-70924 (E), Issue 1.0
    CHAPTER 2 INSTALLATION
    Installation Procedure for Data Interface
    Figure 2-14  Cable Connection between M03 Card and V.35 DTE/Modem
    NOTE:When you provide V.35 DTE using TXC(1) signal, this connection is required.
    (Continued)
    V35 CONNECTOR
    STRAIGHT CABLE (LOCALLY PROVIDED)
    M03
    V. 3 5
    DTE
    (J) (J) (P) (P)
    4 m (13.1 ft.)
    MAX 15 m (49.2 ft.) TXD 4A
    4B
    RXD 2A
    2B
    RTS 6A
    CTS 6B
    DSR 5A
    GND 6D
    DCD 5B
    TXC(2) 3A
    3B
    RXC 1C
    2D
    DTR 5C
    TXC(1) 3C
    4D
    TXD P
    S
    RXD R
    T
    RT S C
    CTS D
    DSR E
    GND B
    GND A
    DCD F
    TXC(2) Y
    AA
    RXC V
    X
    DTR H
    TXC(1) U
    WTXD P
    S
    RXD R
    T
    RTS C
    CTS D
    DSR E
    GND B
    GND A
    DCD F
    TXC(2) Y
    AA
    RXC V
    X
    DTR H
    TXC(1) U
    W
    NOTE DPC V35 CABLE
    Page 36
    (1)  Direct Connection 
    						
    							CHAPTER 2 INSTALLATION
    Installation Procedure for Data Interface
    NEAX2000 IVS2 Data Interface System Manual    
    ND-70924 (E), Issue 1.0   Page 35
    Figure 2-15  Cable Connection between M03 Card and V.35 DTE/Modem
    V35 CONNECTOR
    REVERSE CABLE (LOCALLY PROVIDED)
    M03
    V.35
    MODEM
    (J) (J) (P) (P)
    4 m (13.1 ft.)
    MAX 15 m (49.2 ft.) TXD 4A
    4B
    RXD 2A
    2B
    RTS 6A
    CTS 6B
    DSR 5A
    GND 6D
    DCD 5B
    TXC(2) 3A
    3B
    RXC 1C
    2D
    DTR 5C
    TXC(1) 3C
    4D
    TXD P
    S
    RXD R
    T
    RT S C
    CTS D
    DSR E
    GND B
    GND A
    DCD F
    TXC(2) Y
    AA
    RXC V
    X
    DTR H
    TXC(1) U
    WTXD P
    S
    RXD R
    T
    RTS C
    CTS D
    DSR E
    GND B
    GND A
    DCD F
    TXC(2) Y
    AA
    RXC V
    X
    DTR H
    TXC(1) U
    W
    (2)  Modem Connection
    DPC V35 CABLE
    Page 36 
    						
    							 NEAX2000 IVS2 Data Interface System ManualPage 36  ND-70924 (E), Issue 1.0
    CHAPTER 2 INSTALLATION
    Installation Procedure for Data Interface
    Figure 2-16  DPC V35 Cable
    DA (J)(J)
    1
    6B
    NN
    6D-GND
    2A-RXDA
    2B-RXDB
    4A-TXDA
    4B-TXDB
    6A-RTS
    6B-CTS
    3C-TXC(1)A
    4D-TXC(1)B
    3A-TXC(2)A
    3B-TXC(2)B
    5A-DSR
    5B-DCD
    1C-RXCA
    6
    5
    4
    3
    2
    1RTS
    DSR
    TXDA
    TXC(2)A
    RXDA
    GA
    CTS
    DCD
    TXDB
    TXC(2)B
    RXDBB
    DTR
    TXC(1)A
    RXCAC
    GND
    TXC(1)B
    RXCBD
    X:  NOT CONNECTED
    G: GROUND
    2D-RXCB
    5C-DTR
    1A-GNDB-GND
    R-RXDA
    T-RXDB
    P-TXDA
    S-TXDB
    C-RTS
    D-CTS
    U-TXC(1)A
    W-TXC(1)B
    Y-TXC(2)A
    AA-TXC(2)B
    E-DSR
    F-DCD
    Y-RXCA
    X-RXCB
    H-DTR
    A-GND
    BGND
    F DCD
    LX
    RRXDA
    VRXCA
    ZX
    DD X
    JJ X
    NN XDCTS
    JX
    NX
    TRXDB
    XRXCB
    BB X
    FF X
    LL XAGND
    EDSR
    KX
    PTXDA
    U TXC(1)A
    Y TXC(2)A
    CC X
    HH X
    MM XCRTS
    HDTR
    MX
    STXDB
    W TXC(1)B
    AA TXC(2)B
    EE X
    KK X 
    						
    							CHAPTER 2 INSTALLATION
    Installation Procedure for Data Interface
    NEAX2000 IVS2 Data Interface System Manual    
    ND-70924 (E), Issue 1.0   Page 37
    Figure 2-17  V.35 Connector Pin Assignment Table 2-3  V.35 Interface Cable Connector Pin Assignments
    Pin Name Function Specification Source
    A
    B
    C
    D
    E
    F
    HGND
    GND
    RTS
    CTS
    DSR
    RLSD
    DTRFrame Ground
    Signal Ground
    Request To Send
    Clear To Send
    Data Set Ready
    Received Line Signal Detector
    Data Terminal Ready—
    —
    RS-232
    RS-232
    RS-232
    RS-232
    RS-232—
    —
    DTE
    DCE
    DCE
    DCE
    DTE
    P
    STXD Send Data V.35 DTE
    R
    TRXD Receive Data V.35 DCE
    U
    WSCTE Serial Clock Transmit External (A)
    Serial Clock Transmit External (B)V.35 DTE
    V
    XSCR Serial Clock Receive (A)
    Serial Clock Receive (B)V.35 DCE
    Y
    AA (or aa)SCT Serial Clock Transmit (A)
    Serial Clock Transmit (B)V.35 DCE
    L, M, N, Z, BB, CC, DD, EE, 
    HH, JJ, KK, LL, MM, NNReserved for future V.35 use
    B
    F
    R
    V
    D
    T
    X
    Signal Pin
    Chassis Ground A
    Request To Send C
    Data Set Ready E
    Data Terminal Ready H
    Transmitted Data P
    Transmitted Data S
    Transmit Timing U
    Transmit Timing W
    Transmit Timing Y
    Transmit Timing AAPin Signal
    B Signal Ground
    D Clear To Send
    F Receive Line Signal 
    Detect
    R Received Data
    T Received Data
    V Receive Timing
    X Receive Timing
    A
    E
    P
    U
    Y
    C
    H
    S
    W
    AA 
    						
    							 NEAX2000 IVS2 Data Interface System ManualPage 38  ND-70924 (E), Issue 1.0
    CHAPTER 2 INSTALLATION
    Installation Procedure for Data Interface
    INSTALLATION PROCEDURE FOR DIGITAL TRUNK 
    INTERFACE
    Installation Summary for Digital Trunk Interface
    Install the equipment according to the procedure shown in Figure 2-18.
    Figure 2-18  Installation Procedure for DTI
    NOTE:This procedure is required when you provide CONN card to connect a coaxial cable for
    30DTI.
    START
    Selection of PLO in
    MP Card
    Mounting DTI Card
    DTI Cable Connection
    Page 39
    CHAPTER 5 Page 63
    Page 40
    via MDF
    Mounting CONN CardPage 39 NOTE
    END
    DTI Cable ConnectionPage 43 NOTEvia CONN Card 
    						
    							CHAPTER 2 INSTALLATION
    Installation Procedure for Data Interface
    NEAX2000 IVS2 Data Interface System Manual    
    ND-70924 (E), Issue 1.0   Page 39
    Mounting DTI Card
    (1) Before mounting the DTI (PN-24DTA-C/PN-30DTC-A) card, set the MB 
    switch to UP position, and set the other switches to appropriate position. 
    See CHAPTER 5.Page 63
    (2) Mount the DTI card in the following AP slots on PIM0-PIM7.
    PIM0: AP00-AP10 slots
    PIM1-7: AP00-AP11 slots
    After mounting the card, set the MB to DOWN position to put the card in service.
    NOTE:The DTI card (DTI 0, DTI 1) which sends a clock signal to PLO of the MP card must be
    mounted in the AP slots on PIM0.
    Mounting CONN Card
    When you provide CONN (PZ-M542/M557) card to connect a coaxial cable for 30DTI, do the
    following installation.
    (1) Confirm the correct switch settings of the CONN card. 
    See CHAPTER 5.Page 63
    (2) Mount the CONN card on LTC connector on BWB in the PIM which accomodates the DTI 
    cards.
    For details, refer to the Installation Procedure Manual.
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required 
    						
    							 NEAX2000 IVS2 Data Interface System ManualPage 40  ND-70924 (E), Issue 1.0
    CHAPTER 2 INSTALLATION
    Installation Procedure for Data Interface
    DTI Cable Connection via MDF
    When you use a twisted-pair cable, connect the cable to a CSU via the MDF as shown below.
     Location of AP Slots and LTC Connectors for DTI - Page 41
     Example of MDF Cross Connection for DTI - Page 42
    Figure 2-19  DTI Cable Connection via MDF
    CSU MDF
    LTC0/LTC1/LTC2/LTC3 CONNECTORTWISTED-PAIR
    CABLE BWBPBX
    (PIM0-PIM7)
    MAX. 200 m (655 ft.)
    Figure 2-20, Figure 2-21,
    Figure 2-22, Figure 2-23
    (SHIELD TYPE)
    DTI 
    						
    							CHAPTER 2 INSTALLATION
    Installation Procedure for Data Interface
    NEAX2000 IVS2 Data Interface System Manual    
    ND-70924 (E), Issue 1.0   Page 41
    Figure 2-20  Location of the AP Slots and the LTC Connectors for DTI
    LTC0
    01 
    02 
    03
    04
    05
    06
    07
    08
    09
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25RA 
    TA 
     
     
     
     
     
     
    RA 
    TA 
     
     
     
     
     
     
    RA 
    TA 
     
     
     
     
     
     
    MJ 
     RB 
    TB 
     
     
     
     
     
     
    RB 
    TB 
     
     
     
     
     
     
    RB 
    TB 
     
     
     
     
     
     
    MNRA 
    TA 
     
     
     
     
     
     
    RA 
    TA 
     
     
     
     
     
     
    RA 
    TA 
     
     RB 
    TB 
     
     
     
     
     
     
    RB 
    TB 
     
     
     
     
     
     
    RB 
    TBRA 
    TA 
     
     
     
     
     
     
    RA 
    TA 
     
     
     
     
     
     
    RA 
    TA 
     
     RB 
    TB 
     
     
     
     
     
     
    RB 
    TB 
     
     
     
     
     
     
    RB 
    TBRA 
    TA 
     
     
     
     
     
     
    RA 
    TA 
     
     
     
     
     
     
    RA 
    TA 
     
     RB 
    TB 
     
     
     
     
     
     
    RB 
    TB 
     
     
     
     
     
     
    RB 
    TB 26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50
    AP00 
    SLOT
    AP01 
    SLOT
    AP02 
    SLOT
    LTC1
    01 
    02 
    03
    04
    05
    06
    07
    08
    09
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    2526
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50
    AP03 
    SLOT
    AP04 
    SLOT
    AP05 
    SLOT
    LTC2
    01 
    02 
    03
    04
    05
    06
    07
    08
    09
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    2526
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50
    AP08 
    SLOT
    AP07 
    SLOT
    AP06 
    SLOT
    AP11 
    SLOT
    AP10 
    SLOT
    AP09 
    SLOT
    LTC3
    01 
    02 
    03
    04
    05
    06
    07
    08
    09
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    2526
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50
    L 
    T 
    1 
    1 
    / 
    A 
    P 
    1 
    1 L 
    T 
    1 
    0 
    / 
    A 
    P 
    1 
    0 
      L 
    T 
    0 
    9 
    / 
    A 
    P 
    0 
    9 
      L 
    T 
    0 
    8 
    / 
    A 
    P 
    0 
    8 
      L 
    T 
    0 
    7 
    / 
    A 
    P 
    0 
    7 
      L 
    T 
    0 
    6 
    / 
    A 
    P 
    0 
    6 
      L 
    T 
    0 
    5 
    / 
    A 
    P 
    0 
    5 
      L 
    T 
    0 
    4 
    / 
    A 
    P 
    0 
    4 
      L 
    T 
    0 
    3 
    / 
    A 
    P 
    0 
    3 
      L 
    T 
    0 
    2 
    / 
    A 
    P 
    0 
    2 
      L 
    T 
    0 
    1 
    / 
    A 
    P 
    0 
    1 
      L 
    T 
    0 
    0 
    / 
    A 
    P 
    0 
    0 
      
    						
    							 NEAX2000 IVS2 Data Interface System ManualPage 42  ND-70924 (E), Issue 1.0
    CHAPTER 2 INSTALLATION
    Installation Procedure for Data Interface
    Figure 2-21  Example of MDF Cross Connection for DTI
    17 
    18 
    19 
    20RA 
    TA42 
    43 
    44 
    45RB 
    TB LTC1 (J)42 
    43 
    44 
    45RB 
    TB17 
    18 
    19 
    20RA 
    TA LTC1 (P) PIM 0
    JP MDF DTI
    AP05
    RA
    RB
    TA
    TB17
    42
    18
    4317
    42
    18
    43RA
    RB
    TA
    TBTO CSU LTC1
    RECEIVE
    TRANSMIT 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax 2000 Ivs2 Data Interface System Manual