CHAPTER 5 CIRCUIT CARD INFORMATION List of Required Circuit Cards NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 85 Switch Settings The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK JP0 For coaxial connectors (No.0 circuit) LEFTFor champ connector (LT connector) (No.0 circuit) JP1 For coaxial connectors (No.1 circuit) LEFTFor champ connector (LT connector) (No.1 circuit) JP2 For coaxial connectors (No.2 circuit) LEFTFor champ connector (LT connector) (No.2 circuit) RIGHT RIGHT RIGHT
NEAX2000 IVS2 Data Interface System ManualPage 86 ND-70924 (E), Issue 1.0 CHAPTER 5 CIRCUIT CARD INFORMATION List of Required Circuit Cards PZ-M557 (CONN) Locations of Lamps, Switches and Connectors Lamp Indications This card has no lamps. JP2 RCV20 FOR No.2 CIRCUIT LT CJP1LTTO LTC CONNECTOR ON BWB IN PIM TO CHAMP CONNECTOR (MDF) JP0 TRS20 TRS00 FOR No.0 CIRCUIT COAXIAL CONNECTORRCV00RCV10 FOR No.1 CIRCUIT TRS10
CHAPTER 5 CIRCUIT CARD INFORMATION List of Required Circuit Cards NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 87 Switch Settings The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK JP0 For coaxial connectors (No. 0 circuit) LEFTFor champ connector (LT connector) (No. 0 circuit) JP1 For coaxial connectors (No. 1 circuit) LEFTFor champ connector (LT connector) (No. 1 circuit) JP2 For coaxial connectors (No. 2 circuit) LEFTFor champ connector (LT connector) (No. 2 circuit) RIGHT RIGHT RIGHT
NEAX2000 IVS2 Data Interface System ManualPage 88 ND-70924 (E), Issue 1.0 CHAPTER 5 CIRCUIT CARD INFORMATION List of Required Circuit Cards PN-2DPCB (DPC) Location of Lamps, Switches and Connectors SW0 XCN1 XCN0 RS1 RS0BL1 LB11 LB12 RSC1 SDT1 RDR1 CDI1 RSC0 SDT0 RDR0 CDI0BL0 LB01 LB02 SW1 To X.21 DTE/DCE or PN-M03 To V.24/V.28 DTE/DCE
CHAPTER 5 CIRCUIT CARD INFORMATION List of Required Circuit Cards NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 89 Lamp Indications LAMP NAMECOLOR FUNCTION BL0 Red No. 0 CircuitON: Ready for digital data transmission or the circuit is busy. OFF: Fixed path is not connected. Flash (60IPM): Make-busy state or the system data for this card is not assigned. Flash (120IPM): Fixed path is connected. LB01 Red ON: Loop Back 1 is set. OFF: Normally operating. LB02 Red ON: Loop Back 2 is set. OFF: Normally operating. RSC0 Green ON: RTS/C signal ON OFF: RTS/C signal OFF SDT0 Green ON: TXD/T signal is “0”. OFF: TXD/T signal is “1”. RDR0 Green ON: RXD/R signal is “0”. OFF: RXD/R signal is “1”. CDI0 Green ON: DCD/I signal ON OFF: DCD/I signal OFF (Continued)
NEAX2000 IVS2 Data Interface System ManualPage 90 ND-70924 (E), Issue 1.0 CHAPTER 5 CIRCUIT CARD INFORMATION List of Required Circuit Cards Switch SettingsBL1 Red No. 1 CircuitON: Ready for digital data transmission or the circuit is busy. OFF: Fixed path is not connected. Flash (60IPM): Make-busy state or the system data for this card is not assigned. Flash (120IPM): Fixed path is connected. LB11 Red ON: Loop Back 1 is set. OFF: Normally operating. LB12 Red ON: Loop Back 2 is set. OFF: Normally operating. RSC1 Green ON: RTS/C signal ON OFF: RTS/C signal OFF SDT1 Green ON: TXD/T signal is “0”. OFF: TXD/T signal is “1”. RDR1 Green ON: RXD/R signal is “0”. OFF: RXD/R signal is “1”. CDI1 Green ON: DCD/I signal ON OFF: DCD/I signal OFF SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTIONCHECK SW1 (Piano Key SW)1ON No. 0 CircuitLoop Back 1 ON Loop Back 1 OFF 2ON Loop Back 2 ON Loop Back 2 OFF 3ON No. 1 CircuitLoop Back 1 ON Loop Back 1 OFF 4ON Loop Back 2 ON Loop Back 2 OFF (Continued) LAMP NAMECOLOR FUNCTION 4 3 2 1 OFF ON OFF OFF OFF OFF
CHAPTER 5 CIRCUIT CARD INFORMATION List of Required Circuit Cards NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 91 The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE:When the power is on, disconnect the cables before unplugging the circuit card, and connect the cables after plugging the circuit card. SW0 (Dip SW) 1ONNo. 0 CircuitForcibly turning the DTR signal to ON OFFThe DTR signal from DTE goes through the card 2ONForcibly turning the RTS/C signal to ON OFFThe RTS/C signal from DTE goes through the card 3 Not used 4ON V.11 (X.21) interface OFFV.24/V.28 (RS-232C) interface 5ONNo. 1 CircuitForcibly turning the DTR signal to ON OFFThe DTR signal from DTE goes through the card 6ONForcibly turning the RTS/C signal to ON OFFThe RTS/C signal from DTE goes through the card 7 Not used 8ON V.11 (X.21) interface OFFV.24/V.28 (RS-232C) interface SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTIONCHECK 1 23 45 67 8ON OFF OFF
NEAX2000 IVS2 Data Interface System ManualPage 92 ND-70924 (E), Issue 1.0 CHAPTER 5 CIRCUIT CARD INFORMATION List of Required Circuit Cards PN-M03 (M03) Location of Lamps, Switches and Connectors V35 JP1A JP1BRS OPE SD RD CD ER DR CS SELX21 To PN-2DPCB To V.35 DTE/DCE SELCN0 X21 CN0 SW0 OPRS OPER OPSD
CHAPTER 5 CIRCUIT CARD INFORMATION List of Required Circuit Cards NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 93 Lamp Indications LAMP NAMECOLOR FUNCTION OPE Green ON: This card is normally connected to the PN-2DPCB. OFF: This card is abnormally connected to the PN-2DPCB. RS Green ON: RTS signal is ON. OFF: RTS signal is OFF. SD Green ON: TXD signal is “0” (Space condition). OFF: TXD signal is “1” (Mark condition). RD Green ON: RXD signal is “0” (Space condition). OFF: RXD signal is “1” (Mark condition). CD Green ON: DCD signal is ON. OFF: DCD signal is OFF. ER Green ON: DTR signal is ON. OFF: DTR signal is OFF. DR Green ON: DSR signal is ON. OFF: DSR signal is OFF. CS Green ON: CTS signal is ON. OFF: CTS signal is OFF. SELX21 Green ON: Connecting to the PN-2DPCB is available. OFF: Connecting to the PN-2DPCB is not available. SELCN0 Green Not used
NEAX2000 IVS2 Data Interface System ManualPage 94 ND-70924 (E), Issue 1.0 CHAPTER 5 CIRCUIT CARD INFORMATION List of Required Circuit Cards Switch Settings The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE:The JP1A and JP1B must be set to the same position each other. SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SW0 (Dip SW) 1 Always set to OFF 2 Not used JP1A (Jumper pin) NOTETXC(2) signal is sent out. Left TXC(2) signal is inputted. JP1B (Jumper pin) NOTETXC(2) signal is sent out. Left TXC(2) signal is inputted. OPSD (Jumper pin)RightSet the function of extending distance for TXD signal. Cancel the function of extending distance for TXD signal. OPRS (Jumper pin)RightSet the function of extending distance for RTS signal. Cancel the function of extending distance for RTS signal. OPER (Jumper pin)RightSet the function of extending distance for DTR signal. Cancel the function of extending distance for DTR signal. 1 2ON OFF OFF Right Right Left Left Left