    							CHAPTER 5 CIRCUIT CARD INFORMATION
    List of Required Circuit Cards
    NEAX2000 IVS2 Data Interface System Manual    
    ND-70924 (E), Issue 1.0   Page 85
    Switch Settings
    The figure in the SWITCH NAME column and the position in   in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the
    figure and  , the setting of the switch varies with the system concerned.
    SWITCH NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    JP0 For coaxial connectors
    (No.0 circuit)
    LEFTFor champ connector
    (LT connector) (No.0 circuit)
    JP1 For coaxial connectors 
    (No.1 circuit)
    LEFTFor champ connector
    (LT connector) (No.1 circuit)
    JP2 For coaxial connectors
    (No.2 circuit)
    LEFTFor champ connector
    (LT connector) (No.2 circuit)
    RIGHT
    RIGHT
    RIGHT 
    						
    							 NEAX2000 IVS2 Data Interface System ManualPage 86  ND-70924 (E), Issue 1.0
    CHAPTER 5 CIRCUIT CARD INFORMATION
    List of Required Circuit Cards
    PZ-M557 (CONN)
    Locations of Lamps, Switches and Connectors
    Lamp Indications
    This card has no lamps.
    JP2
    RCV20
    FOR 
    No.2 
    CIRCUIT 
     
    LT CJP1LTTO LTC CONNECTOR 
    ON BWB IN PIM TO CHAMP 
    CONNECTOR (MDF)
    JP0
    TRS20
    TRS00
    FOR 
    No.0 
    CIRCUIT
    COAXIAL CONNECTORRCV00RCV10
    FOR 
    No.1 
    CIRCUIT
    TRS10 
    						
    							CHAPTER 5 CIRCUIT CARD INFORMATION
    List of Required Circuit Cards
    NEAX2000 IVS2 Data Interface System Manual    
    ND-70924 (E), Issue 1.0   Page 87
    Switch Settings
    The figure in the SWITCH NAME column and the position in   in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the
    figure and  , the setting of the switch varies with the system concerned.
    SWITCH NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    JP0 For coaxial connectors
    (No. 0 circuit)
    LEFTFor champ connector
    (LT connector) (No. 0 circuit)
    JP1 For coaxial connectors 
    (No. 1 circuit)
    LEFTFor champ connector
    (LT connector) (No. 1 circuit)
    JP2 For coaxial connectors
    (No. 2 circuit)
    LEFTFor champ connector
    (LT connector) (No. 2 circuit)
    RIGHT
    RIGHT
    RIGHT 
    						
    							 NEAX2000 IVS2 Data Interface System ManualPage 88  ND-70924 (E), Issue 1.0
    CHAPTER 5 CIRCUIT CARD INFORMATION
    List of Required Circuit Cards
    PN-2DPCB (DPC)
    Location of Lamps, Switches and Connectors
    SW0
    XCN1
    XCN0
    RS1
    RS0BL1
    LB11
    LB12 RSC1
    SDT1
    RDR1
    CDI1
    RSC0
    SDT0
    RDR0
    CDI0BL0
    LB01
    LB02
    SW1
    To X.21 DTE/DCE 
    or PN-M03
    To V.24/V.28 DTE/DCE 
    						
    							CHAPTER 5 CIRCUIT CARD INFORMATION
    List of Required Circuit Cards
    NEAX2000 IVS2 Data Interface System Manual    
    ND-70924 (E), Issue 1.0   Page 89
    Lamp Indications
    LAMP 
    NAMECOLOR FUNCTION
    BL0 Red No. 0 
    CircuitON:  Ready for digital data transmission or the 
    circuit is busy.
    OFF: Fixed path is not connected.
    Flash (60IPM):  Make-busy state or the system 
    data for this card is not assigned.
    Flash (120IPM):  Fixed path is connected.
    LB01 Red ON:  Loop Back 1 is set.
    OFF: Normally operating.
    LB02 Red ON:  Loop Back 2 is set.
    OFF: Normally operating.
    RSC0 Green ON: RTS/C signal ON
    OFF: RTS/C signal OFF
    SDT0 Green ON: TXD/T signal is “0”.
    OFF: TXD/T signal is “1”.
    RDR0 Green ON: RXD/R signal is “0”.
    OFF: RXD/R signal is “1”.
    CDI0 Green ON: DCD/I signal ON
    OFF: DCD/I signal OFF
    (Continued) 
    						
    							 NEAX2000 IVS2 Data Interface System ManualPage 90  ND-70924 (E), Issue 1.0
    CHAPTER 5 CIRCUIT CARD INFORMATION
    List of Required Circuit Cards
    Switch SettingsBL1 Red No. 1
    CircuitON:  Ready for digital data transmission or the 
    circuit is busy.
    OFF: Fixed path is not connected.
    Flash (60IPM):  Make-busy state or the system 
    data for this card is not assigned.
    Flash (120IPM):  Fixed path is connected.
    LB11 Red ON:  Loop Back 1 is set.
    OFF: Normally operating.
    LB12 Red ON:  Loop Back 2 is set.
    OFF: Normally operating.
    RSC1 Green ON: RTS/C signal ON
    OFF: RTS/C signal OFF
    SDT1 Green ON: TXD/T signal is “0”.
    OFF: TXD/T signal is “1”.
    RDR1 Green ON: RXD/R signal is “0”.
    OFF: RXD/R signal is “1”.
    CDI1 Green ON: DCD/I signal ON
    OFF: DCD/I signal OFF
    SWITCH NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTIONCHECK
    SW1
    (Piano Key SW)1ON No. 0 
    CircuitLoop Back 1 ON
    Loop Back 1 OFF
    2ON Loop Back 2 ON
    Loop Back 2 OFF
    3ON No. 1 
    CircuitLoop Back 1 ON
    Loop Back 1 OFF
    4ON Loop Back 2 ON
    Loop Back 2 OFF
    (Continued)
    LAMP 
    NAMECOLOR FUNCTION
    4 
    3 
    2 
    1 OFF
    ON
    OFF
    OFF
    OFF
    OFF 
    						
    							CHAPTER 5 CIRCUIT CARD INFORMATION
    List of Required Circuit Cards
    NEAX2000 IVS2 Data Interface System Manual    
    ND-70924 (E), Issue 1.0   Page 91
    The figure in the SWITCH NAME column and the position in in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the
    figure and , the setting of the switch varies with the system concerned.
    NOTE:When the power is on, disconnect the cables before unplugging the circuit card, and
    connect the cables after plugging the circuit card. SW0 (Dip SW)
    1ONNo. 0 
    CircuitForcibly turning the DTR 
    signal to ON
    OFFThe DTR signal from DTE 
    goes through the card
    2ONForcibly turning the RTS/C 
    signal to ON
    OFFThe RTS/C signal from 
    DTE goes through the 
    card
    3 Not used
    4ON V.11 (X.21) interface
    OFFV.24/V.28 (RS-232C) 
    interface
    5ONNo. 1 
    CircuitForcibly turning the DTR 
    signal to ON
    OFFThe DTR signal from DTE 
    goes through the card
    6ONForcibly turning the RTS/C 
    signal to ON
    OFFThe RTS/C signal from 
    DTE goes through the 
    card
    7 Not used
    8ON V.11 (X.21) interface
    OFFV.24/V.28 (RS-232C) 
    interface
    SWITCH NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTIONCHECK
    1
    23
    45
    67
    8ON
    OFF
    OFF 
    						
    							 NEAX2000 IVS2 Data Interface System ManualPage 92  ND-70924 (E), Issue 1.0
    CHAPTER 5 CIRCUIT CARD INFORMATION
    List of Required Circuit Cards
    PN-M03 (M03)
    Location of Lamps, Switches and Connectors
    V35
    JP1A JP1BRS OPE
    SD
    RD
    CD
    ER
    DR
    CS
    SELX21
    To PN-2DPCB
    To V.35 DTE/DCE SELCN0 X21
    CN0 SW0
    OPRS
    OPER
    OPSD 
    						
    							CHAPTER 5 CIRCUIT CARD INFORMATION
    List of Required Circuit Cards
    NEAX2000 IVS2 Data Interface System Manual    
    ND-70924 (E), Issue 1.0   Page 93
    Lamp Indications
    LAMP 
    NAMECOLOR FUNCTION
    OPE Green ON:  This card is normally connected to the PN-2DPCB.
    OFF:  This card is abnormally connected to the PN-2DPCB.
    RS Green ON: RTS signal is ON.
    OFF: RTS signal is OFF.
    SD Green ON:  TXD signal is “0” (Space condition).
    OFF: TXD signal is “1” (Mark condition).
    RD Green ON:  RXD signal is “0” (Space condition).
    OFF:  RXD signal is “1” (Mark condition).
    CD Green ON:  DCD signal is ON.
    OFF:  DCD signal is OFF.
    ER Green ON:  DTR signal is ON.
    OFF:  DTR signal is OFF.
    DR Green ON:  DSR signal is ON.
    OFF:  DSR signal is OFF.
    CS Green ON: CTS signal is ON.
    OFF: CTS signal is OFF.
    SELX21 Green ON:  Connecting to the PN-2DPCB is available.
    OFF:  Connecting to the PN-2DPCB is not available.
    SELCN0 Green Not used 
    						
    							 NEAX2000 IVS2 Data Interface System ManualPage 94  ND-70924 (E), Issue 1.0
    CHAPTER 5 CIRCUIT CARD INFORMATION
    List of Required Circuit Cards
    Switch Settings
    The figure in the SWITCH NAME column and the position in   in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the
    figure and  , the setting of the switch varies with the system concerned.
    NOTE:The JP1A and JP1B must be set to the same position each other.
    SWITCH
    NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    SW0 (Dip SW)
    1 Always set to OFF
    2 Not used
    JP1A (Jumper pin)
    NOTETXC(2) signal is sent out.
    Left TXC(2) signal is inputted.
    JP1B (Jumper pin)
    NOTETXC(2) signal is sent out.
    Left TXC(2) signal is inputted.
    OPSD
    (Jumper pin)RightSet the function of extending 
    distance for TXD signal.
    Cancel the function of extending 
    distance for TXD signal.
    OPRS
    (Jumper pin)RightSet the function of extending 
    distance for RTS signal.
    Cancel the function of extending 
    distance for RTS signal.
    OPER
    (Jumper pin)RightSet the function of extending 
    distance for DTR signal.
    Cancel the function of extending 
    distance for DTR signal.
    1 2ON
    OFF
    OFF
    Right
    Right
    Left
    Left
    Left 
    						