NEC Neax 2000 Ivs Remote Pim System Manual
Here you can view all the pages of manual NEC Neax 2000 Ivs Remote Pim System Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 61
ND-46550 (E) CHAPTER 3 Pag e 53 Revision 2.0 Figure 3-29 LTC Connector Pin Arrangement (PIM B - UB) LTC0 (FP1) (FP2) (FP3) 26 1 LEN0128 /0256 /0384 LT 0 0 27 2 0129 /0257 /0385 28 3 0130 /0258 /0386 29 4 0131 /0259 /0387 30 5 0132 /0260 /0388 31 6 0133 /0261 /0389 32 7 0134 /0262 /0390 33 8 0135 /0263 /0391 34 9 0136 /0264 /0392 LT 0 1 35 10 0137 /0265 /0393 36 11 0138 /0266 /0394 37 12 0139 /0267 /0395 38 13 0140 /0268 /0396 39 14 0141 /0269 /0397 40 15 0142 /0270 /0398 41 16 0143 /0271 /0399 42 17...
Page 62
CHAPTER 3 ND-46550 (E) Pag e 5 4 Revision 2.0 2.2.9 Power Failure Transfer (PFT) The PN-AUCA card or the PZ-8PFTA card can be used as the PFT card at the remote site. (1) When using PN-AUCA card •Figure 3-30 shows an outline of a PFT (PN-AUCA) connection. •Figure 3-31 shows the MDF cross connection for a PFT (PN-AUCA). Figure 3-30 PFT Connection Outline (PN-AUCA) MDF TEL PN-AUCAPBX MDF PN-4COTTO C.O. LINE
Page 63
ND-46550 (E) CHAPTER 3 Pag e 55 Revision 2.0 Figure 3-31 MDF Cross Connection for PFT (PN-AUCA) 1 26 2 27 3 28 4 29 5 30 6 31 7 32 8 33 C.O.R0 C.O.T0 C.O.R1 C.O.T1 PN-4COT1 26 2 27 3 28 4 29 TO STATIONSta. R0 Sta. T0 Sta. R1 Sta. T1 MDF PIM0 PN-AUCA LT00 5 30 6 31 7 32 8 33 JPLTC0 4Q-TW-0.3 CONN CA LT01 LEN0000 (No. 0) LEN0001 (No. 1) CN1 04 03 02 01 CN1 04 03 02 01LEN0004 (No. 0) LEN0005 (No. 1) Ring TO STATION Tip Tip Ring TO C.O. LINE TO C.O. LINE Ring Ring Tip Tip
Page 64
CHAPTER 3 ND-46550 (E) Pag e 5 6 Revision 2.0Figure 3-31 MDF Cross Connection for PFT (PN-AUCA) (Continued) Note 1: The No. 2 and No. 3 circuits in the PN-4COT card cannot be used with the PFT function. Note 2:When using Ground Start trunks with the PFT function, the single line stations must have a ground send- ing button and a ground lead must be run to the station. (2) When using PZ-8PFTA card at a remote site •Figure 3-32 shows an outline of a PFT (PZ-8PFTA) connection. Figure 3-32 PFT...
Page 65
ND-46550 (E) CHAPTER 3 Pag e 57 Revision 2.0 • Install the PZ-8PFTA card to the PIM according to the following steps. STEP 1: Connect the champ connectors of 25-pair cables to the PFT0 and PFT1 connectors on the PZ-8PFTA card as shown in Figure 3-33. Then, secure them to each other using screws and tie wraps. Figure 3-33 Connection of 25-Pair Cable and PZ-8PFTA + + 25-PAIR CABLE CHAMP CONNECTOR (Provided with PZ-8PFTA) PFT0 CONNECTOR PFT1 CONNECTOR PZ-8PFTA + +TO MDF (See STEP 3: )
Page 66
CHAPTER 3 ND-46550 (E) Pag e 5 8 Revision 2.0 STEP 2:Hook the PZ-8PFTA card at the front bracket on the PIM, and secure them to each other using screws and SPL washers, as shown in Figure 3-34. Figure 3-34 Mounting PZ-8PFTA Card to PIM SPL WASHER SCREW PZ-8PFTA PIM + + + +
Page 67
ND-46550 (E) CHAPTER 3 Pag e 59 Revision 2.0 STEP 3:Connect the 25-pair cables on the MDF referring to Figure 3-35 and Figure 3-36. •Figure 3-35 shows the PFT connector pin assignment for each PFT circuit number (No. 0 - No. 7). Figure 3-35 PFT Connector Pin Assignment PFT0 PFT0 26 Sta. T0 1 Sta. R0 27 4LC. T0 2 4LC. R0 28 C.O. T0 3 C.O. R0 29 4COT. T0 4 4COT. R0 30 Sta. T1 5 Sta. R1 31 4LC. T1 6 4LC. R1 32 C.O. T1 7 C.O. R1 33 4COT. T1 8 4COT. R1 34 Sta. T2 9 Sta. R2 35 4LC. T2 10 4LC. R2 36 C.O. T2...
Page 68
CHAPTER 3 ND-46550 (E) Pag e 6 0 Revision 2.0 •Figure 3-36 shows the MDF cross connection for the No. 0 circuit on the PFT (PZ-8PFTA), as an example. Figure 3-36 MDF Cross Connection for PFT (PZ-8PFTA) TO S TATI ON 283 272 294 261 272 283 261 294 JP LT 0 0 327 316 338 305 316 327 305 338 PN-4COT LT 0 1261 Sta. R0 Sta. T0 283 C.O. R0 C.O. T0 294 4COT. R0 4COT. T0 272 4LC. R0 4LC. T0PFT0 TO C. O. L INE PZ-8PFTA No. 0 PJ PFT1 Tip Ring Tip Ring MDF...
Page 69
ND-46550 (E) CHAPTER 3 Pag e 61 Revision 2.0 Figure 3-36 MDF Cross Connection for PFT (PZ-8PFTA) (Continued) 3 LTC0 CONNECTOR 2 PFT1 CONNECTOR 23 MJ ALM 48 24 49 E 25 50 –27V48 23 MJ ALM 49 E 24 50 –27V 25 PFT1 (J) 26 Sta. T0 1 Sta. R0 27 4LC. T0 2 4LC. R0 28 C.O. T0 3 C.O. R0 29 4COT. T0 4 4COT. R0 T01 Sta. R0 26 Sta. T0 2 4LC. R0 27 4LC. T0 3 C.O. R0 28 C.O. T0 4 4COT. R0 29 4COT. T0 T0 26 T0 1 R0 27 2 28 3 29 4 30 T0 5 R0 31 6 32 7 33 8 LTC0 (J) (P) LEN0000 LEN0004 1R026T0 227 328 429 5R030T0...
Page 70
CHAPTER 3 ND-46550 (E) Pag e 6 2 Revision 2.0 2.3 Connection Between Main Site and Remote Site 2.3.1 DTI Connection at Main Site (1) When using the LTC connector on BWB Connect the cable to a CSU or directly to the Remote PIM via the MDF as shown in Figure 3-37. Figure 3- 38 shows an example of cable connections when the DAIA/DAIC card is mounted in the AP0 slot of PIM0. Connection of DAIC cards between the Main PIM and the Remote PIM is available in the same manner as the DAIA-DAIB connection Figure...