    							 ND-46550 (E) CHAPTER 3
    Pag e 53
    Revision 2.0 Figure 3-29    LTC Connector Pin Arrangement (PIM B - UB)
    LTC0 (FP1) (FP2) (FP3)
    26 1 LEN0128 /0256 /0384
    LT 0 0 27 2 0129 /0257 /0385
    28 3 0130 /0258 /0386
    29 4 0131 /0259 /0387
    30 5 0132 /0260 /0388
    31 6 0133 /0261 /0389
    32 7 0134 /0262 /0390
    33 8 0135 /0263 /0391
    34 9 0136 /0264 /0392
    LT 0 1 35 10 0137 /0265 /0393
    36 11 0138 /0266 /0394
    37 12 0139 /0267 /0395
    38 13 0140 /0268 /0396
    39 14 0141 /0269 /0397
    40 15 0142 /0270 /0398
    41 16 0143 /0271 /0399
    42 17 0144 /0272 /0400
    LT 0 2 43 18 0145 /0273 /0401
    44 19 0146 /0274 /0402
    45 20 0147 /0275 /0403
    46 21 0148 /0276 /0404
    47 22 0149 /0277 /0405
    48 23 0150 /0278 /0406
    49 24 LEN0151 /0279 /0407
    50 MN 25 MJLTC1 (FP1) (FP2) (FP3)
    26 1 LEN0152 /0280 /0408
    LT 0 3 27 2 0153 /0281 /0409
    28 3 0154 /0282 /0410
    29 4 0155 /0283 /0411
    30 5 0156 /0284 /0412
    31 6 0157 /0285 /0413
    32 7 0158 /0286 /0414
    33 8 0159 /0287 /0415
    34 9 0160 /0288 /0416
    LT 0 4 35 10 0161 /0289 /0417
    36 11 0162 /0290 /0418
    37 12 0163 /0291 /0419
    38 13 0164 /0292 /0420
    39 14 0165 /0293 /0421
    40 15 0166 /0294 /0422
    41 16 0167 /0295 /0423
    42 17 0168 /0296 /0424
    LT 0 5 43 18 0169 /0297 /0425
    44 19 0170 /0298 /0426
    45 20 0171 /0299 /0427
    46 21 0172 /0300 /0428
    47 22 0173 /0301 /0429
    48 23 0174 /0302 /0430
    49 24 LEN0175 /0303 /0431
    50 25
    LTC2 (FP1) (FP2) (FP3 )
    26 1 LEN0176 /0304 /0432
    LT 0 6 27 2 0177 /0305 /0433
    28 3 0178 /0306 /0434
    29 4 0179 /0307 /0435
    30 5 0180 /0308 /0436
    31 6 0181 /0309 /0437
    32 7 0182 /0310 /0438
    33 8 0183 /0311 /0439
    34 9 0184 /0312 /0440
    LT 0 7 35 10 0185 /0313 /0441
    36 11 0186 /0314 /0442
    37 12 0187 /0315 /0443
    38 13 0188 /0316 /0444
    39 14 0189 /0317 /0445
    40 15 0190 /0318 /0446
    41 16 LEN0191 /0319 /0447
    42 17
    43 18
    44 19
    45 20
    46 21
    47 22
    48 23
    49 24
    50 25 
    						
    							CHAPTER 3 ND-46550 (E)  
    Pag e 5 4
    Revision 2.0
    2.2.9 Power Failure Transfer (PFT)
    The PN-AUCA card or the PZ-8PFTA card can be used as the PFT card at the remote site.
    (1) When using PN-AUCA card
    •Figure 3-30 shows an outline of a PFT (PN-AUCA) connection.
    •Figure 3-31 shows the MDF cross connection for a PFT (PN-AUCA).
    Figure 3-30    PFT Connection Outline (PN-AUCA)
    
    MDF TEL
    PN-AUCAPBX
    MDF
    PN-4COTTO C.O. LINE 
    						
    							 ND-46550 (E) CHAPTER 3
    Pag e 55
    Revision 2.0 Figure 3-31    MDF Cross Connection for PFT (PN-AUCA)
    1
    26
    2
    27
    3
    28
    4
    29
    5
    30
    6
    31
    7
    32
    8
    33
    C.O.R0
    C.O.T0
    C.O.R1
    C.O.T1 PN-4COT1
    26
    2
    27
    3
    28
    4
    29
    TO
    STATIONSta. R0
    Sta. T0
    Sta. R1
    Sta. T1
    MDF PIM0
    PN-AUCA LT00
    5
    30
    6
    31
    7
    32
    8
    33
    JPLTC0
    4Q-TW-0.3 CONN CA
    LT01
    LEN0000  (No. 0)
    LEN0001  (No. 1)
    CN1
    04
    03
    02
    01
    CN1 04
    03
    02
    01LEN0004  (No. 0)
    LEN0005  (No. 1)
    Ring
    TO
    STATION Tip
    Tip Ring
    TO
    C.O. LINE
    TO
    C.O. LINE Ring
    Ring Tip
    Tip 
    						
    							CHAPTER 3 ND-46550 (E)  
    Pag e 5 6
    Revision 2.0Figure 3-31    MDF Cross Connection for PFT (PN-AUCA) (Continued)
    Note 1:
    The No. 2 and No. 3 circuits in the PN-4COT card cannot be used with the PFT function.
    Note 2:When using Ground Start trunks with the PFT function, the single line stations must have a ground send-
    ing button and a ground lead must be run to the station.
    (2) When using PZ-8PFTA card at a remote site
    •Figure 3-32 shows an outline of a PFT (PZ-8PFTA) connection.
    Figure 3-32    PFT (PZ-8PFTA) Connection Outline
    Note:
    Using the PN-AUCA card (long line card) instead of the PN-4LC card is not recommended due to the vari-
    ations from Central Office to the PBX; line quality cannot be assured.
    LTC0 (J)(P)
    LEN0004
    LEN0005
    LEN0000
    LEN0001
    26
    27
    28
    29
    30
    31
    32
    33C.O.T0
    C.O.T1
    Sta.T0
    Sta.T11
    2
    3
    4
    5
    6
    7
    8C.O.R0
    C.O.R1
    Sta.R0
    Sta.R11
    2
    3
    4
    5
    6
    7
    8C.O.R0
    C.O.R1
    Sta.R0
    Sta.R11
    2
    3
    4
    5
    6
    7
    8C.O.R0
    C.O.R1
    Sta.R0
    Sta.R126
    27
    28
    29
    30
    31
    32
    33C.O.T0
    C.O.T1
    Sta.T0
    Sta.T126
    27
    28
    29
    30
    31
    32
    33C.O.T0
    C.O.T1
    Sta.T0
    Sta.T1
    PZ-8PFTA
    PBX
    MDF MDFMDF MDF
    TO C.O. 
    LINE PN-4LC PN-4COT
    TEL
    Note 
    						
    							 ND-46550 (E) CHAPTER 3
    Pag e 57
    Revision 2.0
    • Install the PZ-8PFTA card to the PIM according to the following steps.
    STEP 1:
    Connect the champ connectors of 25-pair cables to the PFT0 and PFT1 connectors on the PZ-8PFTA
    card as shown in Figure 3-33. Then, secure them to each other using screws and tie wraps.
    Figure 3-33    Connection of 25-Pair Cable and PZ-8PFTA
    +
    +
    25-PAIR CABLE
    CHAMP CONNECTOR (Provided with PZ-8PFTA)
    PFT0 CONNECTOR
    PFT1 CONNECTOR
    PZ-8PFTA
    +
    +TO MDF
    (See STEP 3: ) 
    						
    							CHAPTER 3 ND-46550 (E)  
    Pag e 5 8
    Revision 2.0
    STEP 2:Hook the PZ-8PFTA card at the front bracket on the PIM, and secure them to each other using screws
    and SPL washers, as shown in Figure 3-34.
    Figure 3-34    Mounting PZ-8PFTA Card to PIM
    SPL WASHER
    SCREW PZ-8PFTA
    PIM
    +
    +
    +
    + 
    						
    							 ND-46550 (E) CHAPTER 3
    Pag e 59
    Revision 2.0
    STEP 3:Connect the 25-pair cables on the MDF referring to Figure 3-35 and Figure 3-36.
    •Figure 3-35 shows the PFT connector pin assignment for each PFT circuit number
    (No. 0 - No. 7).
    Figure 3-35    PFT Connector Pin Assignment
    PFT0
    PFT0
    26 Sta. T0 1 Sta. R0
    27 4LC. T0 2 4LC. R0
    28 C.O. T0 3 C.O. R0
    29 4COT. T0 4 4COT. R0
    30 Sta. T1 5 Sta. R1
    31 4LC. T1 6 4LC. R1
    32 C.O. T1 7 C.O. R1
    33 4COT. T1 8 4COT. R1
    34 Sta. T2 9 Sta. R2
    35 4LC. T2 10 4LC. R2
    36 C.O. T2 11 C.O. R2
    37 4COT. T2 12 4COT. R2
    38 Sta. T3 13 Sta. R3
    39 4LC. T3 14 4LC. R3
    40 C.O. T3 15 C.O. R3
    41 4COT. T3 16 4COT. R3
    42 Sta. T4 17 Sta. R4
    43 4LC. T4 18 4LC. R4
    44 C.O. T4 19 C.O. R4
    45 4COT. T4 20 4COT. R4
    46 Sta. T5 21 Sta. R5
    47 4LC. T5 22 4LC. R5
    48 C.O. T5 23 C.O. R5
    49 4COT. T5 24 4COT. R5
    50 25
    PFT1 PZ-8PFTA
    PFT1
    26 Sta. T6 1 Sta. R6
    27 4LC. T6 2 4LC. R6
    28 C.O. T6 3 C.O. R6
    29 4COT. T6 4 4COT. R6
    30 Sta. T7 5 Sta. R7
    31 4LC. T7 6 4LC. R7
    32 C.O. T7 7 C.O. R7
    33 4COT. T7 8 4COT. R7
    34 9
    35 10
    36 11
    37 12
    38 13
    39 14
    40 15
    41 16
    42 17
    43 18
    44 19
    45 20
    46 21
    47 22
    48 23
    49 E 24
    50 –27V 25
    No. 6
    No. 7
    MJ ALM
    No. 0
    No. 1
    No. 3
    No. 2
    No. 5
    No. 4 
    						
    							CHAPTER 3 ND-46550 (E)  
    Pag e 6 0
    Revision 2.0
    •Figure 3-36 shows the MDF cross connection for the No. 0 circuit on the PFT (PZ-8PFTA), as an example.
    Figure 3-36    MDF Cross Connection for PFT (PZ-8PFTA)
    
    
    
    
    
    
    
    
     
    
    
     
    
    
    
    
     
    
    
    TO S TATI ON
    283
    272
    294
    261
    272
    283 261
    294 JP
    LT 0 0
    327
    316
    338
    305
    316
    327 305
    338 PN-4COT
    LT 0 1261 Sta. R0
    Sta. T0
    283 C.O. R0
    C.O. T0
    294 4COT. R0
    4COT. T0
    272 4LC. R0
    4LC. T0PFT0
    TO C. O. L INE
    PZ-8PFTA
    No. 0
    PJ
    PFT1
    Tip
    Ring
    Tip
    Ring MDF
    
    
    
     
    
    
    
    
    
     
    
    
    
    
    
    
    
     
    
    
    
    
    
    
    
    
    
    
    
    
    
    
     
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    LT C 0Remote PIM
    PN-DAIB
    2525
    T1LEN0001
    (No. 1)R1
    T0LEN0000
    (No. 0)R0
    T2LEN0002
    (No. 2)R2
    T3LEN0003
    (No. 3)R3
    PN-4LC
    T1LEN0005
    (No. 1)R1
    T0LEN0004
    (No. 0)R0
    T2LEN0006
    (No. 2)R2
    T3LEN0007
    (No. 3)R3
    12D
    
     
    
    
    
    PZ-PW86
    –27V
    G
    49
    24
    50 25
    –27V E
    PJ
    MP
    INSTALLATION CABLE23
    MJ ALM 
    						
    							 ND-46550 (E) CHAPTER 3
    Pag e 61
    Revision 2.0 Figure 3-36    MDF Cross Connection for PFT (PZ-8PFTA) (Continued)
    3 LTC0 CONNECTOR
    2 PFT1 CONNECTOR
    23   MJ ALM 48
    24 49 E
    25 50 –27V48 23   MJ ALM
    49 E 24
    50 –27V 25
    PFT1 (J)
    26 Sta. T0 1 Sta. R0
    27 4LC. T0 2 4LC. R0
    28 C.O. T0 3 C.O. R0
    29 4COT. T0 4 4COT. R0 T01 Sta. R0 26 Sta. T0
    2 4LC. R0 27 4LC. T0
    3 C.O. R0 28 C.O. T0
    4 4COT. R0 29 4COT. T0 T0
    26 T0 1 R0
    27 2
    28 3
    29 4
    30 T0 5 R0
    31 6
    32 7
    33 8
    LTC0 (J)
    (P)
    LEN0000
    LEN0004
    1R026T0
    227
    328
    429
    5R030T0
    631
    732
    833
    (P)
    TO PZ-8PFTA
    TO PZ-8PFTA
    TO STATION
    TO PN-4LC
    TO C.O.  LI NE
    TO PN-4COT
    PFT0 (J)
    (P)
    1 PFT0 CONNECTOR
    TO PZ-PW86
    TO PN-DAIB 
    						
    							CHAPTER 3 ND-46550 (E)  
    Pag e 6 2
    Revision 2.0
    2.3 Connection Between Main Site and Remote Site
    2.3.1 DTI Connection at Main Site
    (1) When using the LTC connector on BWB
    Connect the cable to a CSU or directly to the Remote PIM via the MDF as shown in Figure 3-37. Figure 3-
    38 shows an example of cable connections when the DAIA/DAIC card is mounted in the AP0 slot of PIM0.
    Connection of DAIC cards between the Main PIM and the Remote PIM is available in the same manner as
    the DAIA-DAIB connection
    Figure 3-37    DTI Cable Connection via LTC Connector
    CSU MDF
    LTC1/LTC2 CONNECTORTWISTED-PAIR
    CABLE DAIA/ BWBMAIN PIM
    (SHIELD TYPE)
    Note:
    When the Remote PIM is directly connected without CSU, maximum distance is
    1312 ft. (400 m) between the Main PIM and the Remote PIM.
    Note
    CSU: CONNECTION 
    SERVICE UNIT (0.65F cable) MAX.656 ft. (200 m) DAIC 
    						