ND-46550 (E) CHAPTER 3 Pag e 53 Revision 2.0 Figure 3-29 LTC Connector Pin Arrangement (PIM B - UB) LTC0 (FP1) (FP2) (FP3) 26 1 LEN0128 /0256 /0384 LT 0 0 27 2 0129 /0257 /0385 28 3 0130 /0258 /0386 29 4 0131 /0259 /0387 30 5 0132 /0260 /0388 31 6 0133 /0261 /0389 32 7 0134 /0262 /0390 33 8 0135 /0263 /0391 34 9 0136 /0264 /0392 LT 0 1 35 10 0137 /0265 /0393 36 11 0138 /0266 /0394 37 12 0139 /0267 /0395 38 13 0140 /0268 /0396 39 14 0141 /0269 /0397 40 15 0142 /0270 /0398 41 16 0143 /0271 /0399 42 17 0144 /0272 /0400 LT 0 2 43 18 0145 /0273 /0401 44 19 0146 /0274 /0402 45 20 0147 /0275 /0403 46 21 0148 /0276 /0404 47 22 0149 /0277 /0405 48 23 0150 /0278 /0406 49 24 LEN0151 /0279 /0407 50 MN 25 MJLTC1 (FP1) (FP2) (FP3) 26 1 LEN0152 /0280 /0408 LT 0 3 27 2 0153 /0281 /0409 28 3 0154 /0282 /0410 29 4 0155 /0283 /0411 30 5 0156 /0284 /0412 31 6 0157 /0285 /0413 32 7 0158 /0286 /0414 33 8 0159 /0287 /0415 34 9 0160 /0288 /0416 LT 0 4 35 10 0161 /0289 /0417 36 11 0162 /0290 /0418 37 12 0163 /0291 /0419 38 13 0164 /0292 /0420 39 14 0165 /0293 /0421 40 15 0166 /0294 /0422 41 16 0167 /0295 /0423 42 17 0168 /0296 /0424 LT 0 5 43 18 0169 /0297 /0425 44 19 0170 /0298 /0426 45 20 0171 /0299 /0427 46 21 0172 /0300 /0428 47 22 0173 /0301 /0429 48 23 0174 /0302 /0430 49 24 LEN0175 /0303 /0431 50 25 LTC2 (FP1) (FP2) (FP3 ) 26 1 LEN0176 /0304 /0432 LT 0 6 27 2 0177 /0305 /0433 28 3 0178 /0306 /0434 29 4 0179 /0307 /0435 30 5 0180 /0308 /0436 31 6 0181 /0309 /0437 32 7 0182 /0310 /0438 33 8 0183 /0311 /0439 34 9 0184 /0312 /0440 LT 0 7 35 10 0185 /0313 /0441 36 11 0186 /0314 /0442 37 12 0187 /0315 /0443 38 13 0188 /0316 /0444 39 14 0189 /0317 /0445 40 15 0190 /0318 /0446 41 16 LEN0191 /0319 /0447 42 17 43 18 44 19 45 20 46 21 47 22 48 23 49 24 50 25
CHAPTER 3 ND-46550 (E) Pag e 5 4 Revision 2.0 2.2.9 Power Failure Transfer (PFT) The PN-AUCA card or the PZ-8PFTA card can be used as the PFT card at the remote site. (1) When using PN-AUCA card •Figure 3-30 shows an outline of a PFT (PN-AUCA) connection. •Figure 3-31 shows the MDF cross connection for a PFT (PN-AUCA). Figure 3-30 PFT Connection Outline (PN-AUCA) MDF TEL PN-AUCAPBX MDF PN-4COTTO C.O. LINE
ND-46550 (E) CHAPTER 3 Pag e 55 Revision 2.0 Figure 3-31 MDF Cross Connection for PFT (PN-AUCA) 1 26 2 27 3 28 4 29 5 30 6 31 7 32 8 33 C.O.R0 C.O.T0 C.O.R1 C.O.T1 PN-4COT1 26 2 27 3 28 4 29 TO STATIONSta. R0 Sta. T0 Sta. R1 Sta. T1 MDF PIM0 PN-AUCA LT00 5 30 6 31 7 32 8 33 JPLTC0 4Q-TW-0.3 CONN CA LT01 LEN0000 (No. 0) LEN0001 (No. 1) CN1 04 03 02 01 CN1 04 03 02 01LEN0004 (No. 0) LEN0005 (No. 1) Ring TO STATION Tip Tip Ring TO C.O. LINE TO C.O. LINE Ring Ring Tip Tip
CHAPTER 3 ND-46550 (E) Pag e 5 6 Revision 2.0Figure 3-31 MDF Cross Connection for PFT (PN-AUCA) (Continued) Note 1: The No. 2 and No. 3 circuits in the PN-4COT card cannot be used with the PFT function. Note 2:When using Ground Start trunks with the PFT function, the single line stations must have a ground send- ing button and a ground lead must be run to the station. (2) When using PZ-8PFTA card at a remote site •Figure 3-32 shows an outline of a PFT (PZ-8PFTA) connection. Figure 3-32 PFT (PZ-8PFTA) Connection Outline Note: Using the PN-AUCA card (long line card) instead of the PN-4LC card is not recommended due to the vari- ations from Central Office to the PBX; line quality cannot be assured. LTC0 (J)(P) LEN0004 LEN0005 LEN0000 LEN0001 26 27 28 29 30 31 32 33C.O.T0 C.O.T1 Sta.T0 Sta.T11 2 3 4 5 6 7 8C.O.R0 C.O.R1 Sta.R0 Sta.R11 2 3 4 5 6 7 8C.O.R0 C.O.R1 Sta.R0 Sta.R11 2 3 4 5 6 7 8C.O.R0 C.O.R1 Sta.R0 Sta.R126 27 28 29 30 31 32 33C.O.T0 C.O.T1 Sta.T0 Sta.T126 27 28 29 30 31 32 33C.O.T0 C.O.T1 Sta.T0 Sta.T1 PZ-8PFTA PBX MDF MDFMDF MDF TO C.O. LINE PN-4LC PN-4COT TEL Note
ND-46550 (E) CHAPTER 3 Pag e 57 Revision 2.0 • Install the PZ-8PFTA card to the PIM according to the following steps. STEP 1: Connect the champ connectors of 25-pair cables to the PFT0 and PFT1 connectors on the PZ-8PFTA card as shown in Figure 3-33. Then, secure them to each other using screws and tie wraps. Figure 3-33 Connection of 25-Pair Cable and PZ-8PFTA + + 25-PAIR CABLE CHAMP CONNECTOR (Provided with PZ-8PFTA) PFT0 CONNECTOR PFT1 CONNECTOR PZ-8PFTA + +TO MDF (See STEP 3: )
CHAPTER 3 ND-46550 (E) Pag e 5 8 Revision 2.0 STEP 2:Hook the PZ-8PFTA card at the front bracket on the PIM, and secure them to each other using screws and SPL washers, as shown in Figure 3-34. Figure 3-34 Mounting PZ-8PFTA Card to PIM SPL WASHER SCREW PZ-8PFTA PIM + + + +
ND-46550 (E) CHAPTER 3 Pag e 59 Revision 2.0 STEP 3:Connect the 25-pair cables on the MDF referring to Figure 3-35 and Figure 3-36. •Figure 3-35 shows the PFT connector pin assignment for each PFT circuit number (No. 0 - No. 7). Figure 3-35 PFT Connector Pin Assignment PFT0 PFT0 26 Sta. T0 1 Sta. R0 27 4LC. T0 2 4LC. R0 28 C.O. T0 3 C.O. R0 29 4COT. T0 4 4COT. R0 30 Sta. T1 5 Sta. R1 31 4LC. T1 6 4LC. R1 32 C.O. T1 7 C.O. R1 33 4COT. T1 8 4COT. R1 34 Sta. T2 9 Sta. R2 35 4LC. T2 10 4LC. R2 36 C.O. T2 11 C.O. R2 37 4COT. T2 12 4COT. R2 38 Sta. T3 13 Sta. R3 39 4LC. T3 14 4LC. R3 40 C.O. T3 15 C.O. R3 41 4COT. T3 16 4COT. R3 42 Sta. T4 17 Sta. R4 43 4LC. T4 18 4LC. R4 44 C.O. T4 19 C.O. R4 45 4COT. T4 20 4COT. R4 46 Sta. T5 21 Sta. R5 47 4LC. T5 22 4LC. R5 48 C.O. T5 23 C.O. R5 49 4COT. T5 24 4COT. R5 50 25 PFT1 PZ-8PFTA PFT1 26 Sta. T6 1 Sta. R6 27 4LC. T6 2 4LC. R6 28 C.O. T6 3 C.O. R6 29 4COT. T6 4 4COT. R6 30 Sta. T7 5 Sta. R7 31 4LC. T7 6 4LC. R7 32 C.O. T7 7 C.O. R7 33 4COT. T7 8 4COT. R7 34 9 35 10 36 11 37 12 38 13 39 14 40 15 41 16 42 17 43 18 44 19 45 20 46 21 47 22 48 23 49 E 24 50 –27V 25 No. 6 No. 7 MJ ALM No. 0 No. 1 No. 3 No. 2 No. 5 No. 4
CHAPTER 3 ND-46550 (E) Pag e 6 0 Revision 2.0 •Figure 3-36 shows the MDF cross connection for the No. 0 circuit on the PFT (PZ-8PFTA), as an example. Figure 3-36 MDF Cross Connection for PFT (PZ-8PFTA) TO S TATI ON 283 272 294 261 272 283 261 294 JP LT 0 0 327 316 338 305 316 327 305 338 PN-4COT LT 0 1261 Sta. R0 Sta. T0 283 C.O. R0 C.O. T0 294 4COT. R0 4COT. T0 272 4LC. R0 4LC. T0PFT0 TO C. O. L INE PZ-8PFTA No. 0 PJ PFT1 Tip Ring Tip Ring MDF LT C 0Remote PIM PN-DAIB 2525 T1LEN0001 (No. 1)R1 T0LEN0000 (No. 0)R0 T2LEN0002 (No. 2)R2 T3LEN0003 (No. 3)R3 PN-4LC T1LEN0005 (No. 1)R1 T0LEN0004 (No. 0)R0 T2LEN0006 (No. 2)R2 T3LEN0007 (No. 3)R3 12D PZ-PW86 –27V G 49 24 50 25 –27V E PJ MP INSTALLATION CABLE23 MJ ALM
ND-46550 (E) CHAPTER 3 Pag e 61 Revision 2.0 Figure 3-36 MDF Cross Connection for PFT (PZ-8PFTA) (Continued) 3 LTC0 CONNECTOR 2 PFT1 CONNECTOR 23 MJ ALM 48 24 49 E 25 50 –27V48 23 MJ ALM 49 E 24 50 –27V 25 PFT1 (J) 26 Sta. T0 1 Sta. R0 27 4LC. T0 2 4LC. R0 28 C.O. T0 3 C.O. R0 29 4COT. T0 4 4COT. R0 T01 Sta. R0 26 Sta. T0 2 4LC. R0 27 4LC. T0 3 C.O. R0 28 C.O. T0 4 4COT. R0 29 4COT. T0 T0 26 T0 1 R0 27 2 28 3 29 4 30 T0 5 R0 31 6 32 7 33 8 LTC0 (J) (P) LEN0000 LEN0004 1R026T0 227 328 429 5R030T0 631 732 833 (P) TO PZ-8PFTA TO PZ-8PFTA TO STATION TO PN-4LC TO C.O. LI NE TO PN-4COT PFT0 (J) (P) 1 PFT0 CONNECTOR TO PZ-PW86 TO PN-DAIB
CHAPTER 3 ND-46550 (E) Pag e 6 2 Revision 2.0 2.3 Connection Between Main Site and Remote Site 2.3.1 DTI Connection at Main Site (1) When using the LTC connector on BWB Connect the cable to a CSU or directly to the Remote PIM via the MDF as shown in Figure 3-37. Figure 3- 38 shows an example of cable connections when the DAIA/DAIC card is mounted in the AP0 slot of PIM0. Connection of DAIC cards between the Main PIM and the Remote PIM is available in the same manner as the DAIA-DAIB connection Figure 3-37 DTI Cable Connection via LTC Connector CSU MDF LTC1/LTC2 CONNECTORTWISTED-PAIR CABLE DAIA/ BWBMAIN PIM (SHIELD TYPE) Note: When the Remote PIM is directly connected without CSU, maximum distance is 1312 ft. (400 m) between the Main PIM and the Remote PIM. Note CSU: CONNECTION SERVICE UNIT (0.65F cable) MAX.656 ft. (200 m) DAIC