NEC Neax 2000 Ivs Remote Pim System Manual
Have a look at the manual NEC Neax 2000 Ivs Remote Pim System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
ND-46550 (E) CHAPTER 3 Pag e 33 Revision 2.0 Figure 3-13 DAIA-DAIC Cable Connection (Continued) (2) Multiple PIM Configuration (continued) DAICBUS • When mounting 3 DAIA cards and 6 DAIC cards on last PIM CN2 CN1 DAIA CN1 CN2 PIM0 DA I C TBUS RBUS LAST PIM : RMT PCM-0.3 CA : 48-TW-0.2 CONN CA : 48 TW-0.7 CONN CA : 17-TW-0.3 CONN CA-A BUS DA IC DAIA DA I C DAIC DAIA DAIC PCM0PCM1
CHAPTER 3 ND-46550 (E) Pag e 3 4 Revision 2.0 2.2 Installation Procedure for Remote Site 2.2.1 Switch Setting of DAIB Card (1) Location of Lamps, Switches, and Connectors (see Figure 3-14) Figure 3-14 PN-DAIB Card ATTENTIONContents Static Sensitive Handling Precautions Required BUS CN SENSE RUN MB SW1 LINK RED RMTLOOP BL JPS JPR SW2 SW3
ND-46550 (E) CHAPTER 3 Pag e 35 Revision 2.0 (2) Lamp Indications (see Table 3-6) Table 3-6 Lamp Indications on PN-DAIB Card LAMP NAME COLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. LINK Green Lights when a link between this card and a distant office is connected nor- mally. Goes out after 15 seconds of link disconnection. RED Red Lights when detecting PCM signal loss or Frame Alignment signal loss. RMT Red Lights when receiving a alarm signal from a distant office. LOOP – Not used BL Red Lights while data transmission on control channel (D ch). Flashes while FP data downloading.
CHAPTER 3 ND-46550 (E) Pag e 3 6 Revision 2.0 (3) Switch Settings In Table 3-7, the figure in the SWITCH NAME column and the position in in the SETTING POSI- TION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. Table 3-7 Switch Settings on PN-DAIB Card SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SW1 (Rotary SW)0 – F Always set to 0 1 – F Not used MB (Toggle SW) Note UP For make-busy For normal operation SW1 (Piano Key SW) 1Always set to OFF 2Always set to OFF 3Always set to OFF 4 Always set to OFF 0 ON OFF ON OFF 4 3 2 1 OFF OFF OFF OFF
ND-46550 (E) CHAPTER 3 Pag e 37 Revision 2.0 SW2 (Dip SW) 1 ON Control channel signaling data transmission speed: 48 Kbps Control channel signaling data transmission speed: 64 Kbps 2ON DTI frame configuration: 12-Multi Frame DTI frame configuration: 24-Multi Frame 3ONLine code: AMI with ZCS Line code: B8ZS 4 ON Setting of control signal time slot * Time slot number 0, 20, 21, and 22 (TS0/20/21/22) cannot be used for control signal. ** This setting must be identical with the opposite DAIA card. 5ON 6ON 7 OFF 8ON Table 3-7 Switch Settings on PN-DAIB Card (Continued) SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK ON2 134 6857OFF OFF OFF SWITCH NUMBER TIME SLOT NUMBER 45678 OFFONONONON TS1 ON OFF ON ON ON TS2 OFF OFF ON ON ON TS3 ON ON OFF ON ON TS4 OFF ON OFF ON ON TS5 ON OFF OFF ON ON TS6 OFF OFF OFF ON ON TS7 ON ON ON OFF ON TS8 OFF ON ON OFF ON TS9 ON OFF ON OFF ON TS10 OFF OFF ON OFF ON TS11 ON ON OFF OFF ON TS12 OFF ON OFF OFF ON TS13 ON OFF OFF OFF ON TS14 OFF OFF OFF OFF ON TS15 ON ON ON ON OFF TS16 OFFONONONOFF TS17 ON OFF ON ON OFF TS18 OFF OFF ON ON OFF TS19 OFF OFF OFF ON OFF TS23 OFF OFF OFF ON OFF
CHAPTER 3 ND-46550 (E) Pag e 3 8 Revision 2.0 Note: When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit card. SW3 (Dip SW) 1 Set the equalizer according to the cable length between the system and the CSU. OFF 2 OFF 3 OFF 4 Always set to OFF. JPS (Jumper pin) UP Neutral grounding on the transmitting line is provided. Neutral grounding on the transmitting line is not provided. JPR (Jumper pin) UP Neutral grounding on the receiving line is provided. Neutral grounding on the receiving line is not provided. Table 3-7 Switch Settings on PN-DAIB Card (Continued) SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK ON2 134 ON SW-1 SW-2 SW-3 CABLE LENGTH ON ON ON 0 - 131.2 ft. (0 - 40 m) ON ON OFF 131.2 - 262.5 ft. (40 - 80 m) ON OFF ON 262.5 - 394 ft. (80 - 120 m) ON OFF OFF 394 - 525 ft. (120 - 160 m) OFF ON ON 525 - 656 ft. (160 - 200 m) OFF OFF OFF Signal is not sent ON ON OFF DOWN DOWN
ND-46550 (E) CHAPTER 3 Pag e 39 Revision 2.0 2.2.2 Mounting of DAIB Card STEP 1: Set MB switch on the DAIB card to up position. STEP 2: Mount DAIB card in the MP slot on the Remote PIM. STEP 3: After mounting the card, set MB switch to down position. Figure 3-15 Mounting Location of DAIB Card ATTENTIONContents Static Sensitive Handling Precautions Required Remote PIM DAIB CARD LT00LT01LT02LT03LT04LT05LT06LT07LT08LT09LT10MP P W R • Small Platform
CHAPTER 3 ND-46550 (E) Pag e 4 0 Revision 2.0Figure 3-16 Mounting Location of DAIB Card (Continued) ATTENTIONContents Static Sensitive Handling Precautions Required Remote PIM DAIB CARD LT00LT01LT02LT03LT04LT05LT06LT07LT08MP P W R • 1000 IVS
ND-4 655 0 (E) CHAPTER 3 Set M B s wit ch on DA IC c a rd t o up posit ion. M ount DA IC ca rd in th e AP slot on th e Re mote P IM . Afte r m ounting all DA IC c ar ds , s e t M B sw it c h on DA IB c ar d to u p, an d t h en d own. A TTE NTIO N Rem ote PIM DA IC CARD LT 00LT01LT02LT03LT04LT05 LT06/A P00LT 07/A P01LT 08/A P02LT 09/A P03LT 10/A P04 MP • S m all Pl atfo rm AP0 5
CHAPTER 3 ND-46550 (E) Pag e 4 2 Revision 2.0Figure 3-18 Mounting Location of DAIC Card (Remote PIM) (Continued) ATTENTIONContents Static Sensitive Handling Precautions Required Remote PIM DAIC CARD LT00LT01LT02LT03 LT04/AP00LT05/AP01LT06/AP02LT07/AP03LT08/AP04MP P W R • 1000 IVS