Home > NEC > Communications System > NEC Neax 2000 Ivs Remote Pim System Manual

NEC Neax 2000 Ivs Remote Pim System Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax 2000 Ivs Remote Pim System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							 ND-46550 (E) CHAPTER 3
    Pag e 33
    Revision 2.0 Figure 3-13    DAIA-DAIC Cable Connection (Continued)
    (2) Multiple PIM Configuration (continued)
    DAICBUS
    • When mounting 3 DAIA cards and 6 DAIC cards on last PIM
    CN2
    CN1
    DAIA
    CN1 CN2 PIM0
    DA I C
    TBUS
    RBUS LAST PIM
     : RMT PCM-0.3 CA
     : 48-TW-0.2 CONN CA
     : 48 TW-0.7 CONN CA
     : 17-TW-0.3 CONN CA-A
    BUS
    DA IC DAIA DA I C
    DAIC DAIA DAIC
    PCM0PCM1 
    						
    							CHAPTER 3 ND-46550 (E)  
    Pag e 3 4
    Revision 2.0
    2.2 Installation Procedure for Remote Site
    2.2.1 Switch Setting of DAIB Card
    (1) Location of Lamps, Switches, and Connectors (see Figure 3-14)
    Figure 3-14    PN-DAIB Card
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    BUS
    CN SENSE
    RUN
    MB
    SW1
    LINK
    RED
    RMTLOOP
    BL
    JPS
    JPR
    SW2
    SW3 
    						
    							 ND-46550 (E) CHAPTER 3
    Pag e 35
    Revision 2.0
    (2) Lamp Indications (see Table 3-6)
    Table 3-6  Lamp Indications on PN-DAIB Card
    LAMP NAME COLOR FUNCTION
    RUN Green Flashes at 120 IPM while this card is operating normally.
    LINK Green Lights when a link between this card and a distant office is connected nor-
    mally. Goes out after 15 seconds of link disconnection.
    RED Red Lights when detecting PCM signal loss or Frame Alignment signal loss.
    RMT Red Lights when receiving a alarm signal from a distant office.
    LOOP – Not used
    BL Red Lights while data transmission on control channel (D ch). Flashes while 
    FP data downloading. 
    						
    							CHAPTER 3 ND-46550 (E)  
    Pag e 3 6
    Revision 2.0
    (3) Switch Settings
    In Table 3-7, the figure in the SWITCH NAME column and the position in   in the SETTING POSI-
    TION column indicate the standard setting of the switch. When the switch is not set as shown by the figure
    and  , the setting of the switch varies with the system concerned.
    Table 3-7  Switch Settings on PN-DAIB Card
    SWITCH
    NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    SW1 (Rotary 
    SW)0 – F Always set to 0
    1 – F Not used
    MB (Toggle SW)
    Note
    UP For make-busy
    For normal operation
    SW1 (Piano Key 
    SW)
    1Always set to OFF
    2Always set to OFF
    3Always set to OFF
    4
    Always set to OFF
    0
    ON
    OFF
    ON
    OFF
    4
    3
    2
    1
    OFF
    OFF
    OFF
    OFF 
    						
    							 ND-46550 (E) CHAPTER 3
    Pag e 37
    Revision 2.0
    SW2 (Dip SW) 1 ON Control channel signaling data transmission speed: 
    48 Kbps
    Control channel signaling data transmission speed: 
    64 Kbps
    2ON
    DTI frame configuration: 12-Multi Frame
    DTI frame configuration: 24-Multi Frame
    3ONLine code: AMI with ZCS
    Line code: B8ZS
    4 ON Setting of control signal time slot
    * Time slot number 0, 20, 21, and 22 (TS0/20/21/22) 
    cannot be used for control signal.
    ** This setting must be identical with the opposite 
    DAIA card. 5ON
    6ON
    7
    OFF
    8ON Table 3-7  Switch Settings on PN-DAIB Card (Continued)
    SWITCH
    NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    ON2 134 6857OFF
    OFF
    OFF
    SWITCH NUMBER
    TIME SLOT
    NUMBER
    45678
    OFFONONONON TS1
    ON OFF ON ON ON TS2
    OFF OFF ON ON ON TS3
    ON ON OFF ON ON TS4
    OFF ON OFF ON ON TS5
    ON OFF OFF ON ON TS6
    OFF OFF OFF ON ON TS7
    ON ON ON OFF ON TS8
    OFF ON ON OFF ON TS9
    ON OFF ON OFF ON TS10
    OFF OFF ON OFF ON TS11
    ON ON OFF OFF ON TS12
    OFF ON OFF OFF ON TS13
    ON OFF OFF OFF ON TS14
    OFF OFF OFF OFF ON TS15
    ON ON ON ON OFF TS16
    OFFONONONOFF TS17
    ON OFF ON ON OFF TS18
    OFF OFF ON ON OFF TS19
    OFF OFF OFF ON OFF TS23
    OFF
    OFF
    OFF
    ON
    OFF 
    						
    							CHAPTER 3 ND-46550 (E)  
    Pag e 3 8
    Revision 2.0 Note:
    When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit card. SW3 (Dip SW) 1 Set the equalizer according to the cable length 
    between the system and the CSU.
    OFF
    2
    OFF
    3
    OFF
    4 Always set to OFF.
    JPS (Jumper pin) UP Neutral grounding on the transmitting line is 
    provided.
    Neutral grounding on the transmitting line is not 
    provided.
    JPR (Jumper pin) UP Neutral grounding on the receiving line is provided.
    Neutral grounding on the receiving line is not 
    provided. Table 3-7  Switch Settings on PN-DAIB Card (Continued)
    SWITCH
    NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    ON2 134
    ON
    SW-1 SW-2 SW-3 CABLE LENGTH
    ON ON ON 0 - 131.2 ft. (0 - 40 m)
    ON ON OFF 131.2 - 262.5 ft. (40 - 80 m)
    ON OFF ON 262.5 - 394 ft. (80 - 120 m)
    ON OFF OFF 394 - 525 ft. (120 - 160 m)
    OFF ON ON 525 - 656 ft. (160 - 200 m)
    OFF OFF OFF Signal is not sent
    ON
    ON
    OFF
    DOWN
    DOWN 
    						
    							 ND-46550 (E) CHAPTER 3
    Pag e 39
    Revision 2.0
    2.2.2 Mounting of DAIB Card
    STEP 1:
    Set MB switch on the DAIB card to up position.
    STEP 2:
    Mount DAIB card in the MP slot on the Remote PIM. 
    STEP 3:
    After mounting the card, set MB switch to down position.
    Figure 3-15    Mounting Location of DAIB Card
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    Remote PIM
    DAIB CARD
    LT00LT01LT02LT03LT04LT05LT06LT07LT08LT09LT10MP
    P
    W
    R
    • Small Platform 
    						
    							CHAPTER 3 ND-46550 (E)  
    Pag e 4 0
    Revision 2.0Figure 3-16    Mounting Location of DAIB Card (Continued)
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    Remote PIM
    DAIB CARD
    LT00LT01LT02LT03LT04LT05LT06LT07LT08MP
    P
    W
    R
    •
    1000 IVS 
    						
    							 ND-4 655 0 (E)   CHAPTER 3
    Set M B s wit ch  on  DA IC  c a rd  t o  up  posit ion.
    M ount  DA IC  ca rd in th e AP  slot on th e Re mote P IM .
    Afte r  m ounting  all  DA IC  c ar ds ,  s e t  M B sw it c h  on  DA IB  c ar d to  u p,  an d t h en d own.
    A TTE NTIO N
    Rem ote PIM
    DA IC CARD
    LT 00LT01LT02LT03LT04LT05
    LT06/A P00LT 07/A P01LT 08/A P02LT 09/A P03LT 10/A P04
    MP
    •
    S m all Pl atfo rm
    AP0 5 
    						
    							CHAPTER 3 ND-46550 (E)  
    Pag e 4 2
    Revision 2.0Figure 3-18    Mounting Location of DAIC Card (Remote PIM) (Continued)
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    Remote PIM
    DAIC CARD
    LT00LT01LT02LT03
    LT04/AP00LT05/AP01LT06/AP02LT07/AP03LT08/AP04MP
    P
    W
    R
    •
    1000 IVS 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax 2000 Ivs Remote Pim System Manual