ND-46550 (E) CHAPTER 2 Pag e 3 Revision 2.0 CHAPTER 2 SYSTEM DESCRIPTION 1. SYSTEM OUTLINE Remote PIMs can be installed separately in the same building or between the offices via the Public Switching Telephone Network (PSTN). The customers in the remote site can use the same service features as in the main site. Remote PIMs are connected to the main site by T1 (1.5 Mbps) digital interface. Figure 2-1 shows an outline of the Remote PIM System. Figure 2-1 Remote PIM System Outline Note: The remote PIM...
Page 12
CHAPTER 2 ND-46550 (E) Pag e 4 Revision 2.0 2. PIM CONFIGURATION One PIM can be installed respectively as a remote site. A maximum of 3 remote sites can be provided. The number of remote sites determines the number of PIMs in one system. Table 2-1 shows the available PIM configuration for the Remote PIM System. Table 2-1 PIM Configuration NUMBER OF PIM AT MAIN SITE AVAILABLE NUMBER OF REMOTE SITE 1 PIM (1 FP)123 2 PIM (1 FP)123 3 PIM (2 FP)12 _ 4 PIM (2 FP)12 _ 5 PIM (3 FP)1__ 6 PIM (3 FP)1__ 7 PIM (4...
Page 13
ND-46550 (E) CHAPTER 2 Pag e 5 Revision 2.0 3. SYSTEM CONFIGURATION Figure 2-2 shows the system configuration. Figure 2-2 System Configuration TDSWDAIA 1 (FP1) DAIC 1 DAIC 2DAIB (FP1) DAIC 1 DAIC 2 DAIA 2 (FP2) DAIC 3 DAIC 4DAIB (FP2) DAIC 3 DAIC 4 DAIA 3 (FP3) DAIC 5 DAIC 6 FP0 MPDAIB (FP3) DAIC 5Line/TRK Line/TRK Line/TRK DAIC 6Remote PIM 1 Remote PIM 2 Remote PIM 3Remote Site Main Site 23 B Channel 1 D Channel 24 B Channel 24 B Channel 23 B Channel 1 D Channel 24 B Channel 24 B Channel 23 B...
Page 14
CHAPTER 2 ND-46550 (E) Pag e 6 Revision 2.0 4. REQUIRED EQUIPMENT Table 2-2 shows the required equipment for establishing the Remote PIM System. Table 2-2 Required Equipment EQUIPMENT NAME DESCRIPTION SN1308 PIM P-A (PIM Q-UA) Port Interface Module for Small Platform System/Remote PIM system (remote site) A PIM provides 13 card slot for common control, Line/Trunk cards. It also houses a AC/DC power supply and optional batteries for protection from short-term power interruption. Three champ...
Page 15
ND-46550 (E) CHAPTER 2 Pag e 7 Revision 2.0 PN-DAIC (DAIC Card) Digital Interface Channel Expansion Card. This card provides the 1.5Mbps (24 channel) digital interface. 1 through 6 DAIC cards can be provided at main site. In Remote PIM, 2 DAIC cards can be provided. Small Platform PIM: up to 64 line/trunks can be accommodated. 1000 IVS PIM: up to 47 line/trunks can be accommodated. PN-BS00/BS01 (BUS interface Card) BUS interface cards for PIM0 or PIM1 through PIM7 For Remote PIM System, BS00 card is...
Page 16
CHAPTER 2 ND-46550 (E) Pag e 8 Revision 2.0 5. SYSTEM CAPACITY Table 2-3 shows the system capacity. Note 1:1 port is used for the control signaling channel. Note 2:This number refers to the maximum number of remote offices. The remote office can have only one re- mote PIM. Note 3:When the main site consists of 7 or 8 PIMs, a Remote PIM cannot be provided.Table 2-3 System Capacity DESCRIPTIONCAPACITY REMARKS MAIN PIM REMOTE PIM 2000 IVSSMALL PLATFORM (72 Port)1000 IVS (48 Port) Max. number of DAIA...
Page 17
ND-46550 (E) CHAPTER 2 Pag e 9 Revision 2.0 6. SYSTEM CONDITIONS For providing the Remote PIM System to the NEAX2000 IVS, observe the following conditions: (1) The main site must be the NEAX2000 IVS. The Small Platform System cannot be the main site. The main site must be a medium platform (320 ports) or a large platform (512 ports). The small platform (72 ports) cannot be used. (2) The Remote PIM can be a PIM N-UB, a PIM Q-UA, or a PIM AB-A. (3) The Remote PIM can be installed at a maximum of 1312 ft....
Page 18
CHAPTER 2 ND-46550 (E) Pag e 1 0 Revision 2.0 7. TIME SLOT ALLOCATION One time slot of the last 24 time slots provided by the DAIA-DAIB connection is used for the control signaling channels. Figure 2-3 shows an example of time slot allocation when mounting 8 port cards to the Small Platform PIM. Figure 2-3 Time Slot Allocation LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10 DAIB DAIA • 23 time slots for Line/Trunks • 1time slot for control signaling channel Note • 23 time slots for...
Page 19
ND-46550 (E) CHAPTER 2 Pag e 11 Revision 2.0 Figure 2-4 Time Slot Allocation (Continued) LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10 DAIC 0DAIC 1DAIB DAIC 0DAIC 1DAIA TDSW • 23 time slots for Line/Trunks • 1 time slot for control signaling channel Note • 24 time slots for Line/Trunks • 24 time slots for Line/Trunks • Max. 64 time slots for Line/Trunks per Remote Site Remote Site Main Site00-23 24-47 48-63 Highway Channel (3) When using 1 DAIA card, 1 DAIB card, and 4 DAIC...