ND-46550 (E) CHAPTER 3 Pag e 13 Revision 2.0 CHAPTER 3 INSTALLATION 1. PRECAUTION IN HANDLING When handling cards, the installer must wear a grounded wrist strap to protect the circuit card from static electricity, and the installer must engage in the work on a grounded conductive work surface. Figure 3-1 illustrates the actions to take while handling circuit cards. Figure 3-1 Static Electricity Guard CARD FRONT PBX frame earth of equipment. Connect ground wire to FRAME GROUND SCREW Never touch...
Page 22
CHAPTER 3 ND-46550 (E) Pag e 1 4 Revision 2.0Figure 3-1 Static Electricity Guard (Continued) The symbol shown in Figure 3-2 designates procedures in which circuit cards are handled. When engaging in such work, the installer must be careful not to cause damage by static electricity. Figure 3-2 Static-Sensitive Attention Symbol Wear a wrist strap and perform work on a grounded conductive work surface. CIRCUIT CARD CIRCUIT CARD • When setting switches on circuit card • When carrying circuit card...
Page 23
ND-46550 (E) CHAPTER 3 Pag e 15 Revision 2.0 When plugging or unplugging the circuit card, always hold the circuit card by its edge. If you touch another area, you may be exposed to hazardous voltages. CAUTION CARD FRONT Never touch components or soldered surface with bare hands. PBX
Page 24
CHAPTER 3 ND-46550 (E) Pag e 1 6 Revision 2.0 2. INSTALLATION PROCEDURE Install the Remote PIM System according to the following procedure. Figure 3-3 and Figure 3-4 show the installation procedure for the main site and the remote site. Figure 3-3 Installation Procedure for Main Site Switch Setting of DAIA Card START Mounting of DAIA Card Note:For the main site, this manual describes only the installation procedure exclusively required for the Remote PIM System. Refer to the Installation Procedure...
Page 25
ND-46550 (E) CHAPTER 3 Pag e 17 Revision 2.0 Figure 3-4 Installation Procedure for Remote Site Cable Running to MDF* END START Mounting of DAIB Card Unpacking* Marking and Drilling* Switch Setting of DAIB Card Termination of Cables on MDF* Connection between Main Site and Remote Site System Initialization and System Data Entry* Operation Test* Cleaning and Visual Check* Mounting of Front Cover* Note 1:This manual describes only the installation procedure exclusively required for the Remote...
Page 26
CHAPTER 3 ND-46550 (E) Pag e 1 8 Revision 2.0 2.1 Installation Procedure for Main Site 2.1.1 Switch Setting of DAIA Card (1) Location of Lamps, Switches, and Connectors (see Figure 3-5) Figure 3-5 PN-DAIA Card ATTENTIONContents Static Sensitive Handling Precautions Required BUS CN SENSE RUN MB SW1 PCM1 LINK RED RMT LOOP PWR BL PCM0 JPS JPR SW2 SW3
Page 27
ND-46550 (E) CHAPTER 3 Pag e 19 Revision 2.0 (2) Lamp Indications (see Table 3-1) Table 3-1 Lamp Indications on PN-DAIA Card LAMP NAME COLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. LINK Green Lights when a link between this card and a distant office is connected normally. Goes out after 15 seconds of link disconnection. RED Red Lights when detecting PCM signal loss or Frame Alignment signal loss. RMT Red Lights when receiving a alarm signal from a distant office....
Page 28
CHAPTER 3 ND-46550 (E) Pag e 2 0 Revision 2.0 (3) Switch Settings In Table 3-2, the figure in the SWITCH NAME column and the position in in the SETTING POSI- TION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. Table 3-2 Switch Settings on PN-DAIA Card SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SW1 (Rotary SW) Note 1 Note 2 0 – F FP (Firmware Processor) Number...
Page 29
ND-46550 (E) CHAPTER 3 Pag e 21 Revision 2.0 SW2 (Dip SW) 1 ON Control channel signaling data transmission speed: 48 Kbps Control channel signaling data transmission speed: 64 Kbps 2ON DTI frame configuration: 12-Multi Frame DTI frame configuration: 24-Multi Frame 3ONLine code: AMI with ZCS Line code: B8ZS 4 ON Setting of control signal time slot * Time slot number 0, 20, 21, and 22 (TS0/20/21/22) cannot be used for control signal. ** This setting must be identical with the opposite DAIB card. 5ON...
Page 30
CHAPTER 3 ND-46550 (E) Pag e 2 2 Revision 2.0 Note 1: Set the groove on the switch knob to the desired switch position. Note 2:Since DAIA card acts like an FP, the SW1 for DAIA in FPs cannot be set to the same number. Note 3:When power is on, flip MB switch to ON (UP position) before plugging/unplugging the circuit card. Note 4:When the clock signal from a master office is supplied via the line between the Main Site and the Remote Site, set the SW1-1 and SW1-2 according to settings in Table 3-3. In...