Page 11
NEAX2000 IVS CCIS Features and Specifications Page 4NDA-24159, Issue 2 Attendant Camp-On With Tone Indication - CCIS RBT Main Office Main OfficePublic Music Public RG C:6789B:4567 Called Party ReleaseB:4567 C:6789 ROTB: ON HOOK Attendant Tributary OfficeSatellite Office Public Attendant Tributary OfficeSatellite Office Public (NEAX2000) Console Network (NEAX2400/ NEAX2000) (NEAX2000) Network Network Console(NEAX2000) (NEAX2400/ NEAX2000) (NEAX2000) Network Camped On Call hears Music On Hold and Camped...
Page 12
NEAX2000 IVS CCIS Features and Specifications NDA-24159, Issue 2 Pa ge 5 Attendant Controlled Conference - CCIS General Description This feature permits an Attendant (NEAX2400 IMS) to establish a conference, via CCIS, with up to eight parties of stations and/or trunks (inside and outside parties). Operating Procedure To activate an Attendant Controlled Conference - CCIS: 1. A station (conference leader) calls an Attendant (NEAX2400 IMS only) to request a conference. 2. The Attendant connects the...
Page 13
NEAX2000 IVS CCIS Features and Specifications Page 6NDA-24159, Issue 2 Brokerage - Hot Line - CCIS General Description This feature provides a ringdown connection between two stations, each using a Multiline Terminal, in different offices in the CCIS Network. Operating Procedure To access a Brokerage - Hot Line - CCIS from a Multiline Terminal: 1. Lift the handset or press the SPKR key. 2. Press the line/feature key associated with the preassigned station. The destination station is automatically di-...
Page 14
NEAX2000 IVS CCIS Features and Specifications NDA-24159, Issue 2 Pa ge 7 Busy Verification - CCIS General Description This feature permits an Attendant, via the Attendant Console on the NEAX2400 IMS or the NEAX2000 IVS, to interrupt a busy station’s call at another switching office that connected through CCIS. Operating Procedure To activate a Busy Verification - CCIS: 1. Press an idle LOOP key. 2. Dial the desired station number; receive busy tone. 3. Press the BV key. 4. A two-burst tone is sent to...
Page 15
NEAX2000 IVS CCIS Features and Specifications Page 8NDA-24159, Issue 2 Busy Verification - CCIS NEAX2000 CCIS ATT To STA/CO/TIE/CCIS BV STANEAX2400 /NEAX2000 PBX-APBX-B By dialing the busy station number in PBX-A and pressing Busy/Verification Feature key, the Attendant Console can verify Busy status of any station in PBX-A.
Page 16
NEAX2000 IVS CCIS Features and Specifications NDA-24159, Issue 2 Page 9 Busy Verification - CCIS The linking procedure between two switching offices is as follows: Main OfficeBusy Main Office Tributary Office ATT: BVDial C:6789 C:6789B:4567 B:4567 Attendant Console Satellite Office Public Network Tributary Office Attendant Satellite Office Public Network (NEAX2400/ NEAX2000)Tone4567 (BT) (NEAX2000) (NEAX2000) Console (NEAX2000) (NEAX2400/ NEAX2000) (NEAX2000)
Page 17
NEAX2000 IVS CCIS Features and Specifications Page 10Addendum-003 NDA-24159, Revision 2.3 July, 1998 Call Back - CCIS General Description This feature provides inter-office Call Back. A station who has dialed a busy station at another office can set Call Back - CCIS by dialing a feature access code. When this feature has been set, the setting station will ring as soon as the busy station becomes available. Operating Procedure To set a Call Back - CCIS from a Single Line Telephone: 1. Dial the desired...
Page 18
NEAX2000 IVS CCIS Features and Specifications NDA-24159, Revision 2.3 Addendum-003 Page 11July, 1998 Call Back - CCIS 5. When the setting station answers, the originally called station will ring. 6. The originally called stations LCD display shows: To cancel a Call Back - CCIS from a Multiline Terminal: 1. Lift the handset or press the SPKR key; receive dial tone. 2. Press the Call Back feature key; receive service set tone. The feature is canceled. 3. The LCD display shows: Service Conditions 1. If...
Page 19
NEAX2000 IVS CCIS Features and Specifications Page 12NDA-24159, Issue 2 Call Back - CCIS 13.When the calling party dials the Call Back - CCIS feature access code or presses the CALL BACK key, if the called party goes idle (while the calling party is still off hook), the calling party hears ringback tone and the called party hears ringing. If the called party goes off hook, the parties can talk with each other. Tributary OfficeService Set Tone Busy C:6789 A:2345 C:DIALS C:6789B:4567 B:4567 SETTING...
Page 20
NEAX2000 IVS CCIS Features and Specifications NDA-24159, Issue 2 Page 13 Call Back - CCIS 14.When the calling party waits on hook after having set Call Back-CCIS, the link is established as shown be- low: Main Office Main Office Service Tributary Office C:6789 A:2345 C:6789B:4567 B:4567 C: ON HOOK A:2345C:DIALS Public Satellite Office Public Tributary Office Public Satellite Office Public Network Set Tone Network (DT)-4567-(BT)-SHF-1-(SST) TO SET CALL BACK Network Network