Page 341
NEAX2000 IVS Business/Hotel/Data Features and Specifications Page 286NDA-24158, Issue 2 Step Call Step Call General Description This feature allows the Attendant or station user, after calling a busy station, to call an idle station by simply dialing an additional digit. This feature will operate only if the number of the idle station is identical to that of the busy station in all respects, except the last digit. Station Application All stations. Operating Procedure To operate: 1. The dialed station...
Page 342
NEAX2000 IVS Business/Hotel/Data Features and Specifications NDA-24158, Issue 2 Page 287 Supervisory Control of Peripheral Equipment Supervisory Control of Peripheral Equipment General Description When various types of peripheral equipment (such as facsimiles, dictation equipment, Voice Mail, etc.) are con- nected to the line circuits of the NEAX2000 IVS, this feature allows the loop of the line circuit concerned to open for a programmable interval, and send a release signal to the peripheral equipment...
Page 343
NEAX2000 IVS Business/Hotel/Data Features and Specifications Page 288NDA-24158, Issue 2 Synchronous Data Switching Synchronous Data Switching General Description Synchronous data terminals can place switched data calls if both terminals are equipped with Synchronous Data Adapters. Station Application All Multiline Terminals with LCD equipped for Data Communications. Operating Procedure Internal connection between two Multiline Terminal Synchronous Data Adapters To originate a call from a Multiline...
Page 344
NEAX2000 IVS Business/Hotel/Data Features and Specifications NDA-24158, Issue 2 Page 289 Synchronous Data Switching 4. The following shows the maximum data speed in synchronous transmission • PROTIMS (NECs unique): 2.4k/4.8k/9.6kbps • V.110 (CCITTs): 2.4k/4.8k/9.6k/19.2kbps 5. The system provides a transparent data connection (no speed or code conversion) between terminals. If de- vices do not work when directly connected to each other, they will not work when connected using the NEAX2000 IVS. 6. The...
Page 345
NEAX2000 IVS Business/Hotel/Data Features and Specifications Page 290NDA-24158, Issue 2 System Speed Dialing System Speed Dialing General Description This feature provides all users the ability to dial frequently called numbers using an abbreviated call code. Station Application All stations. Operating Procedure Multiline Terminals To initiate a call: 1. Depress the SPKR key or lift the handset and receive extension dial tone. 2. Depress the System Speed Dialing access feature key (one touch key) or dial...
Page 346
NEAX2000 IVS Business/Hotel/Data Features and Specifications NDA-24158, Issue 2 Page 291 System Speed Dialing 8. When Station Message Detail Recording (SMDR) is provided, the actual dialed number is recorded and printed. 9. If the NEAX2000 IVS is designated as KF registration, this feature will not be available. 10. System Speed dialing cannot be used on Trunk Direct Appearances.
Page 347
NEAX2000 IVS Business/Hotel/Data Features and Specifications Page 292NDA-24158, Issue 2 Tenant Service Tenant Service General Description This feature provides for more than one organization (tenant) to share the same NEAX2000 IVS system. Through system programming, each organization may be restricted to its own Central Office trunks, Attendant Consoles and extension group. In addition, incoming calls are directed to the specific tenant. Station Application Not applicable. Operating Procedure No...
Page 348
NEAX2000 IVS Business/Hotel/Data Features and Specifications NDA-24158, Issue 2 Page 293 Terminal Attribute Data Assignment Terminal Attribute Data Assignment General Description This feature provides a Multiline Terminal equipped with a data adapter the ability to assign or change its own terminal attributes. Attributes such as auto answer, baud rate, and half/full duplex operation can be changed. This ability provides the user with the flexibility to adapt to various data communication needs. Station...
Page 349
NEAX2000 IVS Business/Hotel/Data Features and Specifications Page 294NDA-24158, Issue 2 Tie Lines Tie Lines General Description This feature allows any station user dial access or direct access to an E&M Tie Line. Station Application All stations. Operating Procedure To dial access an E&M Tie Line 1. Lift handset and receive dial tone. 2. Dial E&M Tie Line access code. 3. Dial desired number. To directly access an E&M Tie Line 1. Lift handset or depress SPKR key and receive dial tone. 2. Depress line key...
Page 350
NEAX2000 IVS Business/Hotel/Data Features and Specifications NDA-24158, Issue 2 Page 295 Tie Line Tandem Switching Tie Line Tandem Switching General Description This feature allows trunk-to-trunk connections through the NEAX2000 IVS without the need for any Attendant assistance or control. The major use of this feature is in association with a dial tandem tie line network to allow tie line connections and incoming tie line calls automatic access to, and completion of, local Central Office calls. Station...