Page 311
InfoSet 408Issue 1A System Manual6 - 5 Table 6-2 Programming Functions Quick Reference Chart Function NumberFunction Name and Telephone DisplayDescription Programming Values 001-1Internal Call Notification Used to indicate how users are notified of internal calls. If Voice is selected, users can voice announce calls. If Signal Tone is selected, the system sends an audible tone to the called party. 1 = Voice – = Signal Tone Programming Note:To change the default...
Page 312
Issue 1AInfoSet 408 6 - 6Telephone Programming 001-6Trunk Line Direct Access Used to assign how an outside line is accessed. If enabled, the user can press the designated line to directly access the outside line. If disabled, the user must press the designated line key and then go off-hook to access an external line.6 = Enabled – = Disabled 001-7One-Touch Key Direct Access for Outgoing CallsUsed to assign how a one-touch key accesses an outside line. If enabled, the user can press the...
Page 313
InfoSet 408Issue 1A System Manual6 - 7 002-3External Paging Tone AssignmentUsed to assign if an audible tone is sent from the external speaker when call paging is used.3 = Enabled – = Disabled 002-4Internal All Call Page Tone AssignmentUsed to enable or disable the ability to receive an all call page tone system-wide.4 = Enabled – = Disabled 002-5Barge-In Notification Tone Used to enable or disable an audible tone when barging into a conversation.5 = Enabled (Tone Sent) – = Disabled (No Tone...
Page 314
Issue 1AInfoSet 408 6 - 8Telephone Programming 005Automatic Redial Timer Used to set three parameters associated with the Automatic Redial feature. Duration indicates the amount of time the system continues to redial the number. Wait Duration is the amount of time the system waits between call attempts. Number of Times indicates the number of times the system redials to a busy number or when there is no answer. Number Wait of Duration Duration Times 0 = 5 sec. 5 sec....
Page 315
InfoSet 408Issue 1A System Manual6 - 9 010Outgoing Call Access Code for PBX Used to specify the code (number) dialed to access an outside line from a PBX.9– (2-digit access code) Maximum digits = 6 (3 numbers and 3 pauses) Programming Note:For Function 010, press on the InfoSet telephone andon the Electra Elite telephone to enter a pause. You cannot enter two consecutive pauses, there must be a number between a pause. 011Background Music Destination ! Indicates...
Page 316
Issue 1AInfoSet 408 6 - 10Telephone Programming 018-1Night Mode – Monday ! $%&(# Used to assign night mode for Monday.0 = Continuous Day Mode 1 = Night Mode Assignment 1 2 = Night Mode Assignment 2 3 - Continuous Night Mode (Holidays) 018-2Night Mode – Tuesday ! )*+&(# Used to assign night mode for Tuesday. 018-3Night Mode – Wednesday ! *&%*+&(# Used to assign night mode for Wednesday. 018-4Night Mode – Thursday ! ,)-+&(# Used to assign...
Page 317
InfoSet 408Issue 1A System Manual6 - 11 019-1Hunt Group Pilot Number 10 Used to assign extension numbers 10~19 to Hunt Group Pilot Number 10. 1 = Hunt Group Pilot Number Valid – = Hunt Group Pilot Number Invalid A hunt group consists of a series of extensions that are organized so that if the first extension is busy the system hunts for the next extension in the series that is available. Programming Note:To change the default setting for Functions 019-1~019-5, press the dialpad...
Page 318
Issue 1AInfoSet 408 6 - 12Telephone Programming Programming Note:When setting the restricted dial number for Functions 020~023, use line keys 13 to move the cursor to the left and 16 to move the cursor to the right. To advance to the next location where the restricted dial numbers can be entered, press . To clear an entry, press . Re-enter the data. To enter an “X”, which indicates to the system to use any number where X is found, press . An “s” should appear in the second line...
Page 319
InfoSet 408Issue 1A System Manual6 - 13 060-1~060-3For future use 061~064For future use 101Telephone Number Display for Trunk Line 1 Used to assign the trunk line telephone number that is displayed when making and answering trunk line calls. Not Assigned Maximum of 13 digits 102Telephone Number Display for Trunk Line 2 103 Telephone Number Display for Trunk Line 3 104 Telephone Number Display for Trunk Line 4 105 Trunk Line Function...
Page 320
Issue 1AInfoSet 408 6 - 14Telephone Programming 107Trunk Line Type Used to indicate the trunk line type; from a Central Office or from a PBX.1~4 = Central Office Line – = PBX Line 109Trunk Line Dialing Type Used to indicate the type of dialing; Dial Pulse (10 pps/20 pps), Dual Tone Multifrequency, ISDN, or uninstalled. DP = Rotary Dial DTMF = Touchtone ISDN = Integrated Services Digital Network which allows simultaneous voice and data transmission0 =...