Home > NEC > Communications System > NEC Infoset 408 System Manual

NEC Infoset 408 System Manual

Here you can view all the pages of manual NEC Infoset 408 System Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 311

InfoSet 408Issue 1A
System Manual6 - 5    
Table 6-2   Programming Functions Quick Reference Chart 
Function 
NumberFunction Name and 
Telephone DisplayDescription Programming Values
001-1Internal Call Notification
  	 



Used to indicate how users are 
notified of internal calls.  If Voice is 
selected, users can  voice 
announce calls.  If Signal Tone is 
selected, the system sends an 
audible tone to the called party. 1 = Voice
– = Signal Tone
Programming Note:To change the default...

Page 312

Issue 1AInfoSet 408
6 - 6Telephone Programming
001-6Trunk Line Direct Access  Used to assign how an outside line 
is accessed.   If enabled, the user 
can press the designated line to 
directly access the outside line.  If 
disabled, the user must press the 
designated line key and then go 
off-hook to access an external line.6 = Enabled 
– = Disabled 
001-7One-Touch Key Direct Access 
for Outgoing CallsUsed to assign how a one-touch 
key accesses an outside line.  If 
enabled, the user can press the...

Page 313

InfoSet 408Issue 1A
System Manual6 - 7
002-3External Paging Tone 
AssignmentUsed to assign if an audible tone is 
sent from the external speaker 
when call paging is used.3 = Enabled
– = Disabled
002-4Internal All Call Page Tone 
AssignmentUsed to enable or disable the ability 
to receive an all call page tone 
system-wide.4 = Enabled
– = Disabled 
002-5Barge-In Notification Tone  Used to enable or disable an 
audible tone when barging into a 
conversation.5 = Enabled (Tone Sent)
– = Disabled (No Tone...

Page 314

Issue 1AInfoSet 408
6 - 8Telephone Programming
005Automatic Redial Timer
  

Used to set three parameters 
associated with the Automatic 
Redial feature.  
Duration indicates 
the amount of time the system 
continues to redial the number.  
Wait Duration is the amount of time 
the system waits between call 
attempts.  
Number of Times 
indicates the number of times the 
system redials to a busy number or 
when there is no answer.
Number
Wait of
Duration Duration Times  
 
0 = 5 sec. 5 sec....

Page 315

InfoSet 408Issue 1A
System Manual6 - 9
010Outgoing Call Access Code 
for PBX
  


Used to specify the code (number) 
dialed to access an outside line 
from a PBX.9– (2-digit access code)
Maximum digits = 6 (3 numbers and 3 
pauses)
Programming Note:For Function 010, press      on the InfoSet telephone andon the 
Electra Elite telephone to enter a pause.  You cannot enter two consecutive 
pauses, there must be a number between a pause.
011Background Music 
Destination
 ! 

Indicates...

Page 316

Issue 1AInfoSet 408
6 - 10Telephone Programming
018-1Night Mode – Monday
 ! 
$%&(#
Used to assign night mode for 
Monday.0 = Continuous Day Mode
1 = Night Mode Assignment 1
2 = Night Mode Assignment 2
3 - Continuous Night Mode (Holidays)
018-2Night Mode – Tuesday
 ! 
)*+&(#
Used to assign night mode for 
Tuesday.
018-3Night Mode – Wednesday
 ! 
 *&%*+&(#
Used to assign night mode for 
Wednesday.
018-4Night Mode – Thursday
 ! 
,)-+&(#
Used to assign...

Page 317

InfoSet 408Issue 1A
System Manual6 - 11
019-1Hunt Group Pilot Number 10 

 

Used to assign extension numbers 
10~19 to Hunt Group Pilot Number 
10. 1 = Hunt Group Pilot Number Valid
– = Hunt Group Pilot Number Invalid
A hunt group consists of a series of 
extensions that are organized so that 
if the first extension is busy the system 
hunts for the next extension in the 
series that is available.  
Programming Note:To change the default setting for Functions 019-1~019-5, press the dialpad...

Page 318

Issue 1AInfoSet 408
6 - 12Telephone Programming
Programming Note:When setting the restricted dial number for Functions 020~023, use line keys 
13 to move the cursor to the left and 16 to move the cursor to the right.  
To advance to the next location where the restricted dial numbers can be
entered, press 
    . 
To clear an entry, press   
    .  Re-enter the data.
To enter an “X”, which indicates to the system to use any number where X is
found, press
    .  An “s” should appear in the second line...

Page 319

InfoSet 408Issue 1A
System Manual6 - 13
060-1~060-3For future use
061~064For future use
101Telephone Number Display 
for Trunk Line 1
   
Used to assign the trunk line 
telephone number that is displayed 
when making and answering trunk 
line calls.  Not Assigned
Maximum of 13 digits
102Telephone Number Display 
for Trunk Line 2
   
103
Telephone Number Display 
for Trunk Line 3
   
104
Telephone Number Display 
for Trunk Line 4
   
105
Trunk Line Function...

Page 320

Issue 1AInfoSet 408
6 - 14Telephone Programming
107Trunk Line Type
 	 

Used to indicate the trunk line type; 
from a Central Office or from a 
PBX.1~4 = Central Office Line
– = PBX Line
109Trunk Line Dialing Type

   

Used to indicate the type of dialing; 
Dial Pulse (10 pps/20 pps), Dual 
Tone Multifrequency, ISDN, or 
uninstalled.
DP = Rotary Dial
DTMF = Touchtone
ISDN = Integrated Services Digital 
Network which allows simultaneous 
voice and data transmission0 =...