Page 21
21 Chapter 3 - Installing the MVP120 SoftwareMulti-Tech Systems, Inc. MultiVOIP User Guide Press Enter or click Next to continue. 5. The Choose Destination Location dialog box displays. Follow the on-screen instructions. You can either choose the Destination Location of your MVP120 software or select the default destination by clicking Next. If you click Browse, you can select a different destination folder for the MVP120 software. 6. In the Select Program Folder dialog box, select where you want the...
Page 22
22 Chapter 3 - Installing the MVP120 SoftwareMulti-Tech Systems, Inc. MultiVOIP User Guide Click OK to continue. 8. The Setup Complete dialog displays. Click Finish to continue. 9. The following message displays: Click Ye s to continue. 10. The following message displays. Click Ye s to continue. 11. The IP Protocol Default Setup dialog box displays as you continue now with the configuring of your MultiVOIP, which is continued in Chapter 4.
Page 24
Multi-Tech Systems, Inc. MultiVOIP User GuideChapter 4 - Configuring the Master MultiVOIP 24 Chapter 4 - Configuring the Master MultiVOIP The following steps provide instructions for configuring your MVP120. The configuration sequence includes IP Protocol default setup, Channel setup, and Phone Directory Database setup. The numbering of steps continues from the previous section. 12. The IP Protocol Default Setup dialog box displays. The default Frame Type is TYPE_II. If this does not match your IP...
Page 25
Multi-Tech Systems, Inc. MultiVOIP User GuideChapter 4 - Configuring the Master MultiVOIP 25 15. The Ring Count FXO box enables you to set the number of rings received on the FXO interface before hanging up and releasing the line to another call. The default setting is 2 rings. Note: Zero (0) means no incoming calls will be answered. For FXO-to-FXO communications, you can enable a specific kind of FXO Disconnect Options: Current Loss, Tone Detection, or Silence Detection. Check with your in-house phone...
Page 26
Multi-Tech Systems, Inc. MultiVOIP User GuideChapter 4 - Configuring the Master MultiVOIP 26 If you changed the voice coder, ensure that the same voice coder is used on the voice/ fax channel you are calling. Otherwise, you will always get a busy signal. Note: If Automatic Coder is selected, then you need to select the Max Bandwidth from the list. Check with your Network Administrator to determine how much bandwidth is available. 19. The Fax group enables you to send/receive faxes on the selected...
Page 27
Multi-Tech Systems, Inc. MultiVOIP User GuideChapter 4 - Configuring the Master MultiVOIP 27 The Jitter Value defines the average inter-arrival packet deviation (in milliseconds) before the call is automatically disconnected. Jitter is the inter-arrival packet deviation (phase shift of digital pulses) over the transmission medium that causes voice breakup which can be particularly disruptive to voice communications. The default is 20 milliseconds. A higher value means that the voice transmission will be...
Page 28
Multi-Tech Systems, Inc. MultiVOIP User GuideChapter 4 - Configuring the Master MultiVOIP 28 enables you to select either the GateKeeper or Proprietary PhoneBook. Once you have choosen the type of Phone Book database, you can proceed to registering with a Gatekeeper in the following section (entitled, Registering with a Gatekeeper Phone Directory). If you are building a proprietary phone book, proceed to page 31. On page 31 the Building a Proprietary Phonebook Directory section starts with Step 27. It...
Page 29
Multi-Tech Systems, Inc. MultiVOIP User GuideChapter 4 - Configuring the Master MultiVOIP 29 30. Accept the default Port Number 1719. CAUTION: The default setting for the Gatekeeper Port Number is 1719. This can be changed to a different value by the Gatekeeper administrator. If you decide to change the default Port Number, you must use the same number on the Gatekeeper and all other H.323 endpoints. 31. When you are finished with this dialog box, click Add to begin building your phone directory...
Page 30
Multi-Tech Systems, Inc. MultiVOIP User GuideChapter 4 - Configuring the Master MultiVOIP 30 37. Click OK when you are finished and the Phone Directory Database dialog box displays with the first entry in the window. 38. Click OK. 39. The following dialog box displays. Click OK to download default setup. 40. After the setup has been written to the MVP120, the unit is rebooted. 41. Verify that the BOOT LED on the MVP120 is off after the download completes. This may take several minutes as the MVP120...