    							Configuration 3 - 49
    The new partition is automatically mounted. This is indicated by an asterisk (*) next to its name in the partition 
    list. Any unallocated space on t he card is indicated at the left, and additional partitions can be created in it. 
    Partition Management
    Partitions can be individually d ismounted, mounted, deleted, or  formatted as well. These and additional tasks 
    are available from the  Partition Properties dialog:
    To dismount a partition:
    1. Choose the desired partition. 
    2. Tap the  Properties button. The  Partition Properties  dialog appears.
    3. Tap the  Dismount button. The partition is dismou nted. The asterisk disappears next to its name in the 
    partitions list.
    To delete a partition:
    1. Select the desired partition. 
    2. Tap the  Delete button. A warning dialog appears.
    3. Tap the  OK button. The partition is deleted.
    To format a partition:
    1. Choose the desired partition. 
    2. Tap the  Properties button. The  Partition Properties  dialog appears.
    3. Tap the  Dismount button. The partition is dismou nted. The asterisk disappears next to its name in the 
    partitions list.
    4. Tap the  Format button. The Format  dialog appears:  
    						
    							3 - 50 Workabout Pro4 (Windows Embedded CE 6.0) User Guide
    5. Choose your format options. These options include:
    • Version of file system (FAT-16,  for devices holding up to 4 GB; or FAT-32, for devices containing up to 
    32 GB).
    • Number of FATs (File-Allocation Tables).
    • Number of entries allow ed in the root directory.
    • Cluster size (.5 KB to 64 KB).
    There are also two check boxes, which govern:
    • Whether to use the transaction-s afe FAT file system (TFAT). This file system keeps multiple copies of 
    the file-allocation table, changing one while maintaining anoth er as a backup.
    • Whether to perform a  quick format. Quick formatting removes al l reference to data in the partition 
    without erasing the actual partition. Th e partition will be treated as empty, and new data will overwrite it.
    6. Tap  Start. The partition i s formatted. 
    To mount a partition:
    1. Choose the desired partition. 
    2. Tap the  Properties button. The  Partition Properties  dialog appears.
    3. Tap the  Mount button. The partition is mount ed. The asterisk appears next to  its name in the 
    partitions list.
    The  Partition Properties  dialog has buttons for additional functions. Partitions can be  defragmented, and their 
    file structure can be scanned. 
    						
    							Configuration 3 - 51
    Stylus Properties
    • In the Control Panel , choose the Stylus icon.
    Double-Tap
    • In the  Double-Tap  menu, follow the directions to tailor the sensitivity of the s tylus when you tap on 
    the touchscreen.
    Calibration
    Touchscreens rarely require recalibration. However, if your tou chscreen has never been calibrated or if you find 
    that the stylus pointer is not  accurate when you tap on an item , follow the directions below.
    • Choose the  Calibration tab, and then tap on the  Recalibrate button.
    • Follow the directions in the  Calibration tab to recalibrate t he screen You will be p rompted to save the cali-
    bration data.
    NOTE Touchscreen calibration may not be enabled on your unit. If you r screen appears to require reca-
    libration, contact your supervisor.
    NOTE If you do not receive a prompt to save your data, there could b e a problem with your touchscreen 
    hardware. Contact your Zebra representative. 
    						
    							3 - 52 Workabout Pro4 (Windows Embedded CE 6.0) User Guide
    Touch
    This tab allows you to disable the touchscreen.
    • Choose the Touch tab. Select the check box next to  Disable the touch panel.
    System Properties
    This program identifies the com puter software and hardware comp onents, indicating which components are 
    installed, their identification, version or part numbers, and w hether they are enabled or disabled. 
    •In  Control Panel , choose the System Properties  icon.
    • By choosing the  Export button, you can create a log ( SystemProperties.xml) of your current components, 
    which will be placed in the  My Device folder in Windows Explorer. 
    • Instead of expanding each section of items individually, you c an also choose to open all the lists at once by 
    choosing the  Expand button, which will  then change to a  Collapse button to enable you to collapse all the 
    sections as well. 
    						
    							Configuration 3 - 53
    Total Recall
    Total Recall is a Zebra utility de veloped to maintain a pplications and settings during a cold boot, as well as 
    clone settings to other devices . This utility creates a restore point of a device at a known state. This can be 
    used as a backup of the device (t he administrator can clean the terminal and restore the profile at any time), 
    or a clone (the administ rator can store different configurations for different uses to clone to other 
    hand-held computers). 
    • In the  Control Panel , choose the Total Recall icon.
    In the start up screen, you ca n choose from four options: Create Backup, Create Clone , Manage Profile,  and 
    Delete Profile.
    Creating a Backup
    • Tap on the  Create Backup  button to begin the process.
    This dialog box displa ys the Profile Name an d the storage destination for the profile file.
    • In the  Profile Name  field, type a nam e for a profile. 
    NOTETotal Recall works diff erently (e.g. restore on cold boot or on  clean boot) on different OS plat-
    forms and versions (e.g. Windo ws CE 5.0, 6.0, Windows Mobile, W indows Embedded 
    Hand-held). For detailed information and other updates on Total  Recall information, please go to 
    the IngenuityWorking web site at:
    http://community.psion .com/knowledge/w/knowledgebase/total-reca ll.aspx 
    						
    							3 - 54 Workabout Pro4 (Windows Embedded CE 6.0) User Guide
    • If you want to choose another l ocation for your backup file (optional), tap on the [...] button to the right of 
    the  Profile Location  field and choose one of  a number of folders. 
    - Tap on  Start. A backup of the cu rrent settings will be cr eated and saved to the specified location. The 
    unit will then reboot.
    To view profiles and choose r estore options, refer to Managing Profiles on page 3-55 .
    Creating a Clone
    Cloning allows you to copy settings or configurations from one computer to another. There are two types of 
    clones to choose from: a  Full Clone and a Settings Only Clone . 
    A  Full Clone  contains all files, most of the  registry, and the settings files. 
    A  Settings Only Clone  can be copied to a wider array  of devices, but it should not be used as an 
    autorestore profile. 
    • Tap on the  Create Clone button to begin the process. Your Workabout Pro4 model type an d OS will be 
    identified in the cloning statement to ensure that you target d evices of the same type. Give the clone profile 
    a name and location, then tap on  Next.
    • In this menu, select All  for a Full Clone, or Selected Options  for a Settings Only Clone . If you choose 
    Selected Options , a menu will open to ena ble you to decide which options you want cloned.
    IMPORTANTAny profile not stored in persist ent memory (Application, Flash Disk, external USB 
    drive) will be erased  during a clean boot, therefore you should  store profiles on a per-
    sistent drive. 
    When performing an autorestore, th e program only searches for the profile located in 
    the \Application\ or \Flash Dis k\TotalRecall folder. If you store your profile anywhere 
    else it will not be restored. Only one profile can reside in th at folder. 
    IMPORTANTThe target device for a Full Clone MUST have the same model typ e and OS build as 
    the source, otherwise problems can occur. For example, if the t arget device has a 
    newer build of the OS, the new bu ild may have a different set of registry keys that 
    may conflict wit h the source. 
    						
    							Configuration 3 - 55
    Managing Profiles
    You can view profiles and choose profile options from the menus in this section. 
    Viewing a Profile
    • Tap on the Manage Profile  button to see your list of prof iles. Highlight a profile, and then you can choose 
    to  View  the Profile Summary and go on t o the next menu, Profile Details.
    Profile Options
    • Tap on the Manage Profile  button to see your list of prof iles, as shown above. Highlight  a profile, and tap 
    on the  Next button to choose from options to  restore or clone the profile. You can choose from four profile 
    options:  Restore Now , Set for Autorestore , Upload to A.R.C.,  and Clone to USB.
    List of profiles
    Profile SummaryProfile Details 
    						
    							3 - 56 Workabout Pro4 (Windows Embedded CE 6.0) User Guide
    • Next, tap on the option button you want to use:
    •Restore Now  – restores the profile immediately. If you are restoring a pro file that is a backup or Full Clone, 
    the computer will clean reset fi rst; if the profile is a Settings Only Clone , it will not.
    • Set for AutoRestore  – creates a profile that is au tomatically restored following a  cold reset or a clean 
    start. The profile is stored in the  \Flash Disk\TotalRecall folder.
    • Upload to A.R.C  – uploads the profile to the Active Remote Configuration server . After you tap on Send, 
    a message will come up either con firming that the upload was complete or that the connection to the 
    server failed.
    • Clone to USB  – writes a clone of the profile t o the USB drive. After you tap on the button, a message will 
    come up either confirming that t he USB drive is ready for deployment, or that it is not available.
    • When you are ready to install the profile on another unit, tur n on the next computer to be cloned and insert 
    the USB key. The profile will be  automatically installed to the \Flash Disk\TotalRecall folder. There is a short 
    delay in deploym ent so that you can canc el the process if needed.
    IMPORTANTAfter setting an autorestore pro file, that profile will overwrite any other pro file already 
    placed in the Applicat ion\ or \Flash Disk\TotalRecall folder. 
    In an autorestore, Total Recall  only restores the profile located in the Application\ or 
    \Flash Disk\TotalRecall folder. If you store your profile anywh ere else it will not be 
    restored.  
    						
    							Configuration 3 - 57
    Deleting a Profile
    • In the Total Recall  home screen, tap on  Delete Profile.
    • In the next screen,  locate your backup file, and tap on  OK.
    A warning pop-up screen appears  asking if you’re certain that you want to delete this file.
    • Tap on  Ye s to delete the file.
    TweakIt
    This utility allows you  to tweak or adjust Advanced system settings (interface, ne twork, servers, driver, and 
    radio) and provides a  Registry Editor.
    USB drive prepared for cloning Autorun installation on next Workabout Pro 
    						
    							3 - 58 Workabout Pro4 (Windows Embedded CE 6.0) User Guide
    Advanced
    Advanced CE Services Settings
    FTP Server
    This option is enabled by default to allow file transfers. Keep in mind that data transfer in either direction is 
    restricted to the Temp folder — that is, data are always loaded  from the FTP Server  to the Te m p folder and 
    from the  Te m p folder to the  FTP Server.
    If this option is disabled, a war m reset must be performed to a ccept the change.
    Advanced Interface and Network Settings
    Enable IPv6
    This option allows you to enabled Internet Protocol specificati on, version 6, that has been published to enable 
    128-bit IP addresses (replacing version 4).
    Modem Logging
    When this option is enabled, th e Workabout Pro4 logs AT command s (e.g., dial-out information, password 
    string, etc.) that the  administrator can monitor for debugging  purposes. Modem commands are stored in: 
    \MdmLog.txt. 
    						