Page 251

Default Hardware Types 
ORIGINATE ACTIONS 
Action 
1 Send string 
2 Sleep 
3 Flush device 
4 Sleep 
5 Send string 
6 Send access code 
7 Send string 
8 Sleep 
9 Read string 
10 Send string 
11 Flush device 
12 Sleep Parameter 

 
teinet -t 

 
connected 
hangup Timeout 
3 seconds 
2 seconds 
4 seconds 
20 seconds 
2 seconds 
ANSWER ACTIONS 
I I I I 1 
Action Parameter Timeout 
1 Set signal hi DTR 
2 Sleep 3 seconds 
3 Read string hangup 0 seconds 
DISCONNECT ACTIONS 
1 4 
1 Set signal hi 
1 5 1 Set...

Page 252

Default Hardware Types 
RIGINATE ACT10 
Action Parameter Timeout 
1 Send string hello 
2 Sleep 5 seconds 
ANSWER ACT10 
Action Parameter Timeout 
1 Flush device 
2 Sleep 
2 seconds 
3 Read string 
hello 0 seconds 
ISCONNECT ACTIONS 
I I Action Parameter I Timeout 
1 
I I 
Set signal lo DTR 
2 
Sleep 20 seconds 
1 3 1 Set signal hi 1 DTR 
1 
E DROP SIGNAL = CD 
A-9  

Page 253

Default Hardware Types 
ORIGINATE ACTIONS 
i- 
2 
3 
4 
5 
6 
7 
8 
9 
10 
11 
12 
13 Action 
Send string 
Sleep 
Send string 
Sleep 
Flush device 
Send string 
Send access code 
Send string 
Flush device 
Sleep 
Read string 
Flush device 
Sleep 
ANSWER ACTIONS 
Action 
Send string 
Sleep 
Send string 
Sleep 
Flush device 
Sleep 
Read string Parameter 
ATH
 
ATSO=O
 
ATDT 

 
CONNECT 
Parameter 
ATH
 
ATSO=l
 
CONNECT 
DISCONNECT ACTIONS 
Action 
Set signal lo 
Sleep 
Set signal hi 
Sleep 
Send string...

Page 254

Default Hardware Types 
urier 
ORIGINATE ACTIONS - 
- 
1 
2 
3 
f 
5 
6 
7 
8 
9 
10 
11 
12 
13 
- 
Action 
Send string 
Sleep 
Send string 
Sleep 
Flush device 
Send string 
Send access code 
Send string 
Flush device 
Sleep 
Read string 
Flush device 
Sleep Parameter 
ATH
 
ATSO=O
 
ATDT 

 
CONNECT Timeout 
5 seconds 
j seconds 
10 seconds 
60 seconds 
5 seconds 
Action Parameter Timeout 
1 Send string ATH
 
2 Sleep 
5 seconds 
DISCONNECT 
/ Action 
Set signal lo 
Sleep 
Set signal hi 
Sleep 
Send...

Page 255


				            

Page 256

i Prior to the introduction of MESA-Net TCI?/IP, MESA-Net Async used Tellabs 
multiplexing equipment for sites that required high-performance, dedicated digital 
transmission facilities. Although MESA-Net TCP/IP now provides high- 
performance connections, the MESA-Net Async optional feature still contains the 
predefmed hardware types required to work with Tellabs equipment. This appendix 
contains reference information regarding MESA-Net Async and Tellabs equipment, 
specifically the Tellabs 340...

Page 257

Working with Tellabs Equipment 
Example 1: etwork using Tellabs ataplexer/Xplexers 
Figure B-l shows a MESA-Net Async network in which all nodes use Tellabs 330 
Dataplexers and 33 
1 Xplexers for communications. 
San Jose Node 1 
New York Node 4 
Composife Data Link 0 tonne 
Xplexer and Dafaplexer 
Originate link at channel 6 
Answer link at channel 7 
Denver Node 6 
Composite Data Link 1 
Dataplexer 
connects Xplexer and 
Dafaplexer 
Originate link at channel 6 
Answer link at channel 7 
T&labs 330...

Page 258

Working with Tellabs Equipment 
1 he Network Node 1 able entrles for ChIcago are: 
Node Number: 1 
Node Name: San Jose 
String: 
110.7 
Hardware type: 1 
Access (Y/N): Y 4 
New York 
411.7 1 
Y 
The Network Node Table entries for Denver are: 
Node Number: 
1 2 
Node Name: San Jose Chicago 
String: 
l/O.7 210.7 
Hardware type: 1 1 
Access (Y/N) : Y Y .,8,,/ 
611.7 
1 
Y 
4 
New York 
4/1.7 
1 
Y 
The Network Node Table entries for New York are: 
Node Number: 
1 
Node Name: San Jose 
String: 
l/O.7...

Page 259

Working with Tellabs Equipment 
Example 2: Tellabs Datciplexer/Xplexers and Modems 
onnections ial-Up 
Figure B-2 shows a Tellabs 330 Dataplexer/331 Xplexers network and a node in 
Long Island that communicates with the network using dial-up lines that are routed 
through the New York node. All other node-to-node routing is performed by the 
Xplexers. 
San Jose NewYork Node 1 Tellabs 330 Tellabs 331 Tellabs 331 
Xplexer Tellabs 330 
Dataplexer Node 4 
Composite Data Link 1 connects 
Xplexer and...

Page 260

Working with Tellabs Equipment- 
The Network Node Table entries for San Jose are: 
Node Number: 3 4 
Node Name: Long Island New York 
String: 8584661 
411.7 
Hardware type: 
4 1 
Access (Y/N): Y 
Y 
The Network Node Table entries for Denver are: 
6 
Denver 
611.7 
1 
Y 
Node Number: 
Node Name: 
String: 
Hardware type: 
Access (Y/N) : 1 
San Jose 
l/O.7 
1 
Y 3 
Long Island 
8584661 
4 
Y 4 
New York 
4J1.7 
1 
Y 
The Network Node Table entries for New York are: 
Node Number: 
1 
Node Name: San Jose...