Page 31

Installation
21
Installation
Fiber 
Interface 
ModuleInterfaces control node 
with DSU and peripheral 
nodes.1 Maximum Permitted Loss in 
Fiber:
6 dB, using 62.5/125 µm optical 
cable with a numerical aperture 
of 0.275 inches.
Maximum Length:
Approximately 1 km (0 to 5 km 
based on the sum of the cable 
loss and connector and/or splice 
losses. Total loss cannot exceed 
6 dB.).
LS/GS trunk 
cardGround start CO trunks
Loop start CO trunks8 not applicable
ONS and 
ONS 
CLASS/CLIP 
Line CardDTMF (2500)...

Page 32

Technician’s Handbook
22
DSU Cards
Table 3:    DSU Cards
Card Devices Supported # of Channels/Links
BRI Card ISDN Basic Rate Interface card 6 or 15 BRI Circuits
CEPT Formatter Card
(all variants)CEPT digital trunk 60 channels
(two 30-channel links and 
2 D-channels)
Conference Card Flexible assignment for up to 64 
conference channels; up to eight 
conferees per conference call; up to 21 
three-party conferences.64 conference channels
DS1 Formatter Card
(all variants)T1/D4 digital trunk 2 x 24-channel...

Page 33

Installation
23
Installation
Control Cards
Table 4:    Control Cards
Card Important Details
Main Controller II E Provides 8 Mbytes of RAM if system is running software version 
M21.0 or earlier. If the system is running software version M21.1 or 
later, it provides 15 Mbytes of RAM, and therefore the control RAM 
II cards must be removed.
Main Controller III or
Main Controller III RProvides 16 Mbytes of RAM. 
Main Controller III  E Provides 16 Mbytes of RAM if system is running a software version...

Page 34

Technician’s Handbook
24
Card Settings
Control Resource Card Switch Settings
These switches determine which maintenance terminal 
ports are active.
Figure 7:   Control Resource Card
Table 5:   Control Resource Card Switch Settings
Maintenance Data Output
 Switch settings
 S1 S2 S3 S4
Control (or SX-2000 MICRO LIGHT), 
peripheral, and DSU nodes (default)closed closed not used not used
Control (or SX-2000 MICRO LIGHT) node only open  open  not used not used
Peripheral and DSU nodes only open closed not...

Page 35

Installation
25
Installation
E&M Trunk Card Switch Settings
Set switch SN-1 and SN-2 on the E&M trunk cards.
∗Positions are SN-1 and SN-2 where N is the particular trunk circuit number on the card (1 through 4).
Figure 8:   E&M Trunk Card
Table 6:    E&M Trunk Switch Settings
Types of Interface Circuits  Switch Positions
Signal/Carrier Set Types Co-located Trunk Types SN-1∗ SN-2∗ 
TYPE I  NONE  A  B
TYPE II  TYPE II  B  A
TYPE IV  TYPE IV B  A
TYPE V  TYPE I  B  B
TYPE V  TYPE III B  B
TYPE V  TYPE V B  B 

Page 36

Technician’s Handbook
26
OPS Line Card Message Waiting Switches
Set message waiting switches for each circuit (S1 through 
S8) as follows:
Figure 9:   OPS Line Card
Table 7:   OPS Line Card Switch Settings
Setting Description
A Circuits are connected to Off-Premises (OPS) lines. Loop extended over the 
Message-Waiting Answer (MWA)/Message-Waiting Busy (MWB) pair to the 
called extension.
B Circuits are connected to On-Premises (ONS) lines. Consists of a -140 Vdc 
source delivered at a variable rate to...

Page 37

Installation
27
Installation
DS1 Formatter Card Line Equalizer Switches
Set the line equalizer switches S1 and S2 as follows: 
Note:The DS1 interface meets the AT&T DSX-1 specification for distances up to 655 
feet (200 m) if 22 AWG (22 IWG) shielded cable is used. The interface can 
operate at up to 750 feet (229 m), but compliance with the AT&T DSX-1 specifi-
cation is not guaranteed at this distance. For greater distances, a repeater must 
be used. 
CEPT Interface Assembly Jumpers
Jumper positions J06...

Page 38

Technician’s Handbook
28
E1/T1 (DS1) Formatter Card Switch Settings
Set E1/T1 mode using the E1/T1 switches on the card’s side
PRI Cards and DS1/CEPT I and II Cards 
To set the card for LT, remove the NT jumper blocks and 
place them on the LT jumpers.
Figure 10:   Dual E1 PRI Card
Table 10:   E1/T1 (DS1) Formatter Card Switch Settings
E1/T1 Switches
Mode Channel 
24Switch 1 
(Link 1)Switch 2 
(Link 2)
E1 mode (compatible for connection 
to MSDN DS1 trunks that have been 
externally converted from MSDN...

Page 39

Installation
29
Installation
Peripheral Interface Cabling
Use the tables in this section to cable the peripheral node 
card connectors to the Main Distribution Frame (MDF). 
When cabling the SX-2000 MICRO LIGHT node connectors, 
use the cabling tables that correspond to the peripheral 
interface card slot in the MICRO LIGHT node.
Cable Connectors
Use AMP Champ or equivalent cable connectors
!50-pin RS (receptacle - screw lock)
!female
!screw lock
!90 tapered slide-on hood.
USCO Pin Designations
The USCO...

Page 40

Technician’s Handbook
30
Table 11:   USCO Connector Pin Designations
Pin Color 
CodeRJ2IX RJ2EX RJ2GX RJ2FX RJ2HX
26 W/BL T T T T T
1  BL/W R R R R R
27 W/O T  E T1 E T1
2 O/W R M R1 SG R1
28 W/G T T E M E
3 G/W R R M SB SG
29 W/BR T E T T M
4  BR/W R M R R SB
30 W/S T T T1 E T
5 S/W R R R1 SG R
31 R/BL T  E  E  M  T1
6  BL/R R  M M SB R1
32 R/O T T T T E
7  O/R R R R R SG
33 R/G T  E T1 E M
8 G/R R M R1 SG SB
34 R/BR T T E M T
9 BR/R R R M SB R
35 R/S T E T T T1
10 S/R R M R R R1
36 BK/BL T T T1 E E
11...