Page 41
Generic 1002 and Generic 1003 FeaturesTable 84 SUPERSET Telephone Features (continued) Feature1 Generic 1002 1 Generic 1003. Pickup - local and directed Prime LineXX XX Privacy/Privacy ReleaseIXIX Ringer Tone AdjustmentIXIX Ringer Volume Control Secretarial Line Speaker On/Off Speaker Volume ControlXX XX XX XX Speed Call KeysI xX Subattendant Recall Swap (Trade Calls) Swap Campon Timed Reminder Transfer/Conference User Programmable XX X X XX X* x XX XX Paae 3 of 3 Table 8-5 Hotel/Motel Features...
Page 42
General DescriptionTable 8-5 Hotel/Motel Features (continued) Feature( Generic 1002 ) Generic 1003 Message Lamp Test I x I x I Message Register AuditI x I x I Message Registration Property Management System (PMS)XX XX Room Status -Attendant Room Status Display - SUffRPE~4 and SUPfRSET4DN TelephonesXX X Room Status PrintoutXX Page 2 of 2 0 cTable 8-6 Data Features Feature Associated Data Line (ADL)ADL Hotline ADL Speed Call Originate Abbreviated Dial For Data Calls Generic 1002Generic 1003XX XX XX...
Page 43
Generic 1002 and Generic 1003 FeaturesTable 8-6 Data Features (continued) FeatureGeneric 1002Generic 1003 DTRX Call Originate/DisconnectI x I x I DTRX Help DTRX Hotline DTRX MessagesXX XX DTRX Queuing/Camp-on Modem Pooling Modem Pooling QueuingX X Page 2 of 2 1 Table B-7 Maintenance Features FeatureGeneric 1002 Generic 1003 Alarm indicationXX Alarm LEDs Alarm Status Display Automatic Diagnostics Configuration Report Copy Database Customer Data Entry (CDE) Backup and Restore Device Error Analysis...
Page 44
General DescriptionTable 8-7 Maintenance Features (continued) FeatureGeneric 1002Generic 1003 SUW?SE~Telephone Loop TestI xI ISystem Logging FacilityIXIX Test Line Function Page2 of 2 .:100 8-14 9109-094-lOO-NA Issue 3 Revision 1
Page 45
9 109-094-l 05-NA Issue 3 Revision 1September, 1989 SX-ZOO@ DIGITAL PABX Features Description This practice describes each of the features available for the MITEL SX-200 DIGITAL PABX. Feature descriptions include the required conditions, customer data program- ming and operating procedures. Practice : 9 10%094-105-NA Issue:3 Revision:1 Date : September, 1989 Software Version:Cl003 MR3 otopyright 1989, MITEL Corporation. All rights reserved. ‘“Trademark of MITEL Corporation @Registered Trademark of MITEL...
Page 46
Features Description NOTICE The information contained in this document is believed to be accurate in all respects but is not warranted by Mite1 Corporation (MITEL). The information is subject to change without notice and should not be construed in any way as a commitment by Mite1 or any of its affiliates or subsidiaries. Mite1 and its affiliates and subsidiaries as- sume no responsibility for any errors or omissions in this document. Revisions of this document or new editions of it may be issued to...
Page 47
Table of Contents 1. INTRODUCTION......................... General.............................. Reason for Reissue..................... About this practice..................... Practice Structure................... Feature Descriptions................ References........................ Supplementary Information_ _ . . _ . . _ . . _ . Class of Service Options.............. System Options..................... Feature Access Codes................ ........... .......... .......... .......... .............
Page 48
Table of Contents Attendant Message Waiting Setup and Cancel......................105 2-19 Attendant New Call Ring........................................105 2-20 Attendant Night/Day Switching ..................................105 2-20 Attendant Override Announce...................................105 2-21 AttendantPagingAccess........................................10 5 2-21 Attendant Paged Hold Access....................................105 2-23 Attendant Serial...
Page 49
Features Description Device Interconnection Control..................................105 3-27 Dial Tone Disable..............................................105 3-29 Dictation Trunks...............................................105 3-30 DID/Dial-in/Tie Intercepts.......................................105 3-30 Digit Translation.............:.................................105 3-32 Direct-in Lines (OIL)............................................105 3-33 Direct Station Select/ Busy Lamp Field...
Page 50
Table of Contents Non-Busy Extensions...........................................105 3-63 Off-Premise Extension (OPS).....................................105 3-64 Originate Only Extensions.......................................105 3-65 Overlap Outpulsing............................................105 3-66 Override Security.............................................. 105 3-66 Paging.........-.............................................lO 5 3-66 Parallel Connection of Industry-Standard...