Mitel SX 200 DIGITAL Pabx General Descriptions Manual
Here you can view all the pages of manual Mitel SX 200 DIGITAL Pabx General Descriptions Manual. The Mitel manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 11
System Overview of 80 characters each. The two top lines display the steps to be taken, and the two bottom lines display the prompts which define the 10 function keys onthe Attendant Console. For additional information, refer to Practice 9109-094-210-NA, Customer Data Entry (CDE), and to Practice 9109-094-315-NA, Attendant Console Description. 9109-094-l 00-NA Issue 3 Revision 1 100 2-5
Page 13
3. PHYSICAL DESCRIPTIONGENERAL 3.1 The SX-200 Digital PABX consists of a Control cabinet and an optional Peripheral cabinet. With Generic 1002, the following devices are not avail-able: 672-port configuration, Tl trunks, Switch Matrix Card. UNIVERSAL CONTROL CABINET (336-, 456-, AND 480- PORT CONFIGURA- TIONS)3.2 The Control Cabinet for the 336-, 456-, and 480- port configurations con- tains a 144 port digital Control shelf with Bay 1 and Bay 2 in the lower posi- tion. Its Floppy Disk Drives plug...
Page 14
General Description 480-portControl Cabinet3.5 The 5X-200 Digital PABX 480-port Control cabinet (Figure 1-2) contains al20-port analog shelf (Bay 3) above the 144 port Control shelf. An optional 216-port analog Peripheral cabinet (Bays 4 and 5) may be con- nected to the 480-port Control cabinet. Digital Bay 1 contains: 1 Bay Power Supply, 1 Floppy Disk Drive (powered and controlled from Bay 2), and up to 8 Digital Peripheral cards. Digital Bay 2 contains: 1 Main Control Card, 1 Bay Power Supply, 1...
Page 15
Physical Description Bays 4 to 7 each contain:1 Bay Power Supply, 1 Bay Control Card, and up to 8 digital Peripheral cards NOTE:An SX-200 Digital 672-pot-t PABX may also be created by converting an installed 336port Control cabinet to a Peripheral cabinet and add-ing a new 672-port Control cabinet. POWER FAIL TRANSFER 3.9 Power Fail Transfer cards can be provided to connect preselected DTMF or Rotary telephones directly to CO trunks in the event of system failure.MAINTENANCE PANELS 3.10 Two Maintenance...
Page 16
General Description PERIPHEML SHELF I1BAY 4BAY 3 r---1-1 0. i)L JCONTROL SHELF ,,,, MAINTENANCE PANEL h___.-- ___ 3 I -1 0 u0 h POWER DISTRIBUTIONAC FILTER Figure 1-l Universal Control Cabinet with Digital Peripheral Shelf100 3-4 9109-094-lOO-NA issue 3 Revision 1
Page 17
Physical Description BAY 3 POWER SWITCHBAY1BAY 2 ICONTROL SHELF / /CONTROL SHELFPERIPHERAL SHELF /’ ,/ (BAY 3) /’MAINTENANCE PANEL PERIPHERAL SHELF , ---FAN A$SEMBLYPOWER SUPPLY :cc0010 Figure l-2 Universal Control Cabinet with Analog Peripheral Shelf
Page 18
General Bescri ption MAINTENANCIPANEL -BAY5 -BAY 4PCM CABLEBAY 4 BAY PCN CABRESERVE POWER SUPPLY (OPTIONAI100 3-6 .‘L -. *BAY4 -CABLE CLAMPBAY 5 / -‘.\ I -.‘... 1/POWER SUPPLY ’ 1 - I.. \ Figure 1-3 Analog Peripheral Cabinet 9109-094-lOO-NA Issue 3 Revision 1
Page 19
Physical Description BAY 3BAY 2 l-----l- BAY 0BAY1 CONTROL SHELFMAINTENANCE / PANEL BAY 1BAY 0Figure 1-4 672-Part Control Cabinet Ac FILTER9109-094-l 00-NA issue 3 Revision 1 100 3-7
Page 20
General DescriptionPERIPHERAL SHELF1 BAY 7BAY 6 11 uuBAY 5BAY 4 I JPERIPHERAL SHELF 100 3-8BAY 6BAY 7 III \BAY 4BAY 5 AC FILTER Cc000 1 Figure 1-5 672-Poti Peripheral Cabinet 9109-094-IOO-NA Issue 3 Revision 1