SECTION MITL8350-l Ol-l OO-NA TABLE 3: SPECIFIC 909 DEFAULTS PARAMETER r50t & r70t r58t & r78t 602 644 & 684 645 & 685 ;15, 625, 635, 655, 665, & 675 803 Search Table 20, 630, 660, & 670 610 & 650 640 & 680 DEFAULT/ RECOMMENDED (not applicable) 8 SMT 9 #250 2 #833 5 7 #803 2 7 These are the remaining Route Access Control DDD S.C. Note: 602, 610 through 680 programming data entry must be ASCll code. DEFAULT COMPARISON 4.10 Table 4 is a comparison of the 903 versus the 909...
Page 422
SECTION MITL8350-l Ol-l OO-NA now possible. Each Speed Call may now contain its own unique Ac- count Code, if desired. TABLE 4: COMPARISON OF 903 VERSUS 909 DEFAULTS 903 DEFAULTED PARAMETER OOOt: 0 = 10 SPEED CALLS 1 = 100 SPEED CALLS 2 = Maximum 1000 possible speed calls (3 digit address) NOTE: To use Selection 2, the default 803 Speed Call trigger search table entry must be deleted and replaced in the 804 Table or other table as desired. The rec- ommended Speed Call trigger is: 804 = $6...
Page 423
SECTION MITL8350-l Ol-l OO-NA TABLE 4 Con’t: COMPARISON OF 903 VERSUS 909 DEFAULTS 903 DEFAULTED 909 DEFAULTED The maximum length of the field is 30 characters (29 digits and a XC). The maximum length of a Speed Call or Account Code field alone within the 30-character limit is 23 digits. In the 903 Mode, the 6r5 Access Control Strings, of course, must be programmed to dial out the Account Codes, if desired. Speed Dialing may be done on any route in either default format. Note that Route #3 is...
Page 424
SECTION MITL8350-101-l OO-NA 7000 (CONFIRM TONE) 03 3931212## (CONFIRM TONE) 7001 (CONFIRM TONE) 03 3861212## (CONFIRM TONE) 7002 (CONFIRM TONE) 03 3447725&Y (CONFIRM TONE) 7660 (CONFIRM TONE) 03 mrn...mm## (CONFIRM TONE) Des: No. 6) The following examples of entries will cause Account Codes to be dialed out after. the destination number: 7050 (CONFIRM TONE) 7051 (CONFIRM TONE) 7nnn (CONFIRM TONE) 03 5459958 * 1234567 ## (CONFIRM TONE) 03 5661992 * 2345678 ## (CONFIRM TONE) 03 mm...mm ++...
Page 425
SECTION MlTL8350-l Ol-l OO-NA 4) When programming from the User Program Access Code (###), all Speed Calls programmed are routed through the Search Tables (dk = 08). DIALING SPEED CALLS 5.04 Once the Dialer has been installed and depending upon the type of programming, the user may dial Speed Calls. The method to access Speed Calls differs depending on unit usage. If 909 Default programming was used, there are no special instructions required to dial a Speed Call. Simply dial the three-digit...
Page 426
SECTION MITL8350-I Ol-l OO-NA one action digit for a total of five. The “804” is not counted. An entry of 803 #9#9#9#2 is six plus two, for a total of eight. 2) A speed call entry occupies a number of spaces equal to the length of the speed call plus 6 (an internal Dialer requirement), and must be rounded up to the next ewen number if the total is odd. Thus, a Speed Call programmed as “7nn 08 13931212##” requires 14 spaces in memory (8 digits + 6 = 14). The W’, if used to partition an account...
Page 427
SECTION MITL8350-101-100-NA TABLE 6: SEARCH TABLE SCREENS (with no Speed Calls present) QTY. 2,900 2,400 1,800 1,600 1,300 1,200 900 LENGTH OF SCREEN (No Speed Calls Present) 4 Digit Screens 5 Digit Screens 6 Digit Screens 7 Digit Screens 10 Digit Screens 11 Digit Screens 15 Digit Screens Calculation Examples Example 1 100 8-DIGIT 1,600 7-DIGIT SCREENS OR 1,450 8-DIGIT SCREENS OR 1,150 lo-DIGIT SCREENS OR 1,000 ll-DIGIT SCREENS 1,000 8-DIGIT 90 ‘/-DIGIT SCREENS OR 80 8-DIGIT...
Page 428
SECTION MITL8350-lOl-l OO-NA SPEED CALLS SCREENS IN SEARCH TABLES TOTAL SPEED CALL SPACE TOTAL SCREEN SPACE 1 ] TOTAL SPEED CALL SPACE + TOTAL SCREEN SPACE MUST 8E LESS THAN: 15,000 FOR 909 DEFAULTED DIALER AND 14,500 FOR 903 DEFAULTED DIALER. Note a: IF LENGTH+6 IS AN ODD NUMBER, ROUND UP TO NEXT EVEN NUMBER. FIGURE 3: CALCULATION WORKSHEET Page 16
Page 429
SECTION MlTL8350-l Ol-l OO-NA 7. SPECIFICATIONS HARDWARE 7.01 Table 7 lists all of the hardware specifications for the SMarT- lTM Common Carrier Access Dialer and Call Controller. These specifications also apply to the SMarT-‘lATM unit unless otherwise noted. TABLE 7: SMarT-lTM HARDWARE SPECIFICATIONS SPECIFICATlON FCC RINGER EQUIVALENCE IDLE LINE, LOOP START RINGER IMPEDANCE: 15-60 Hz, 70-‘llOV 20-3500 Hz, 1OV RINGING SENSITIVITY: 15-60 Hz LEAKAGE: Tip to Ring, 1OOV Tip to Earth, 1OOV...
Page 430
SECTION MITL8350-101-l OO-NA TABLE 7 CON’T: SMasT-1 TM HARDWARE SPEClFlCATlONS CO SIDE FEED: Gain 300 Hz INTERNAL FEED: DTMF RECEIVER LEVEL LEVEL DIFFERENCE FREQ. To receive To not receive DURATlON TIME BETWEEN TONES ROTARY RECEIVER MAKE IMPEDANCE MAKE DURATION BREAK IMPEDANCE BREAK DURATION RATE DTMF SENDER LEVEL FREQUENCY DURATION (Programmable) ROTARY SENDER TIMING (Programmable) TIMING (At 60140): RATE (At 60/40) INTERDIGIT PAUSE (Programmable) OPERATING RANGE TEMPERATURE...