Page 421

SECTION MITL8350-l Ol-l OO-NA 
TABLE 3: SPECIFIC 909 DEFAULTS 
PARAMETER 
r50t & r70t 
r58t & r78t 
602 
644 & 684 
645 & 685 
;15, 625, 635, 655, 
665, & 675 
803 Search Table 
20, 630, 660, & 670 
610 & 650 
640 & 680 
DEFAULT/ 
RECOMMENDED 
(not applicable) 
8 
SMT 
9 #250 2 #833 5 7 
#803 2 7 
These are the remaining Route Access Control 
DDD 
S.C. 
Note: 
602, 610 through 680 programming data entry must be ASCll 
code. 
DEFAULT COMPARISON 
4.10 Table 4 is a comparison of the 903 versus the 909...

Page 422

SECTION MITL8350-l Ol-l OO-NA 
now possible. Each Speed Call may now contain its own unique Ac- 
count Code, if desired. 
TABLE 4: COMPARISON OF 903 VERSUS 909 DEFAULTS 
903 DEFAULTED 
PARAMETER OOOt: 
0 = 10 SPEED CALLS 
1 = 100 SPEED CALLS 
2 = Maximum 1000 possible speed calls 
(3 digit address) 
NOTE: To use Selection 2, the default 803 
Speed Call trigger search table entry 
must be deleted and replaced in the 804 
Table or other table as desired. The rec- 
ommended Speed Call trigger is: 804 = $6...

Page 423

SECTION MITL8350-l Ol-l OO-NA 
TABLE 4 Con’t: COMPARISON OF 903 VERSUS 909 DEFAULTS 
903 DEFAULTED 
909 DEFAULTED 
The maximum length of the field is 30 characters (29 digits and a XC). The maximum 
length of a Speed Call or Account Code field alone within the 30-character limit is 23 
digits. 
In the 903 Mode, the 6r5 Access Control Strings, of course, must be programmed to 
dial out the Account Codes, if desired. 
Speed Dialing may be done on any route in either default format. Note that Route #3 
is...

Page 424

SECTION MITL8350-101-l OO-NA 
7000 (CONFIRM TONE) 
03 3931212## (CONFIRM TONE) 
7001 (CONFIRM TONE) 
03 3861212## (CONFIRM TONE) 
7002 (CONFIRM TONE) 
03 3447725&Y (CONFIRM TONE) 
7660 (CONFIRM TONE) 
03 mrn...mm## (CONFIRM TONE) 
Des: No. 
6) The following examples of entries will cause Account Codes to 
be dialed out after. the destination number: 
7050 (CONFIRM TONE) 
7051 (CONFIRM TONE) 
7nnn (CONFIRM TONE) 03 5459958 * 1234567 ## (CONFIRM TONE) 
03 5661992 * 2345678 ## (CONFIRM TONE) 
03 
mm...mm ++...

Page 425

SECTION MlTL8350-l Ol-l OO-NA 
4) 
When programming from the User Program Access Code (###), 
all Speed Calls programmed are routed through the Search 
Tables (dk = 08). 
DIALING SPEED CALLS 
5.04 Once the Dialer has been installed and depending upon the type 
of programming, the user may dial Speed Calls. The method to 
access Speed Calls differs depending on unit usage. If 909 Default 
programming was used, there are no special instructions required to 
dial a Speed Call. Simply dial the three-digit...

Page 426

SECTION MITL8350-I Ol-l OO-NA 
one action digit for a total of five. The “804” is not counted. An 
entry of 803 #9#9#9#2 is six plus two, for a total of eight. 
2) A speed call entry occupies a number of spaces equal to the 
length of the speed call plus 6 (an internal Dialer requirement), 
and must be rounded up to the next ewen number if the total is 
odd. Thus, a Speed Call programmed as “7nn 08 13931212##” 
requires 14 spaces in memory (8 digits + 6 = 14). The W’, if 
used to partition an account...

Page 427

SECTION MITL8350-101-100-NA 
TABLE 6: SEARCH TABLE SCREENS (with no Speed Calls present) 
QTY. 
2,900 
2,400 
1,800 
1,600 
1,300 
1,200 
900 LENGTH OF SCREEN (No Speed Calls Present) 
4 Digit Screens 
5 Digit Screens 
6 Digit Screens 
7 Digit Screens 
10 Digit Screens 
11 Digit Screens 
15 Digit Screens 
Calculation Examples 
Example 
1 
100 8-DIGIT 1,600 7-DIGIT SCREENS 
OR 1,450 8-DIGIT SCREENS 
OR 1,150 lo-DIGIT SCREENS 
OR 1,000 ll-DIGIT SCREENS 
1,000 8-DIGIT 90 ‘/-DIGIT SCREENS 
OR 80 8-DIGIT...

Page 428

SECTION MITL8350-lOl-l OO-NA 
SPEED CALLS SCREENS IN 
SEARCH TABLES 
TOTAL SPEED CALL SPACE TOTAL 
SCREEN SPACE 1 ] 
TOTAL SPEED CALL SPACE + TOTAL SCREEN SPACE MUST 8E LESS THAN: 
15,000 
FOR 909 DEFAULTED DIALER AND 
14,500 FOR 903 DEFAULTED DIALER. 
Note a: IF LENGTH+6 IS AN ODD NUMBER, ROUND UP TO NEXT EVEN NUMBER. 
FIGURE 3: CALCULATION WORKSHEET 
Page 16  

Page 429

SECTION MlTL8350-l Ol-l OO-NA 
7. SPECIFICATIONS 
HARDWARE 
7.01 
Table 7 lists all of the hardware specifications for the SMarT- 
lTM Common Carrier Access Dialer and Call Controller. These 
specifications also apply to the SMarT-‘lATM unit unless otherwise 
noted. 
TABLE 7: SMarT-lTM HARDWARE SPECIFICATIONS 
SPECIFICATlON 
FCC RINGER EQUIVALENCE 
IDLE LINE, LOOP START 
RINGER IMPEDANCE: 15-60 Hz, 70-‘llOV 
20-3500 Hz, 1OV 
RINGING SENSITIVITY: 15-60 Hz 
LEAKAGE: Tip to Ring, 1OOV 
Tip to Earth, 1OOV...

Page 430

SECTION MITL8350-101-l OO-NA 
TABLE 7 CON’T: SMasT-1 TM HARDWARE SPEClFlCATlONS 
CO SIDE 
FEED: Gain 300 Hz 
INTERNAL FEED: 
DTMF RECEIVER 
LEVEL 
LEVEL DIFFERENCE 
FREQ. To receive 
To not receive 
DURATlON 
TIME BETWEEN TONES 
ROTARY RECEIVER 
MAKE IMPEDANCE 
MAKE DURATION 
BREAK IMPEDANCE 
BREAK DURATION 
RATE 
DTMF SENDER 
LEVEL 
FREQUENCY 
DURATION (Programmable) 
ROTARY SENDER 
TIMING (Programmable) 
TIMING (At 60140): 
RATE (At 60/40) 
INTERDIGIT PAUSE (Programmable) 
OPERATING 
RANGE 
TEMPERATURE...