Macrotel Mt360 Series Digital Key System Installation Manual
Here you can view all the pages of manual Macrotel Mt360 Series Digital Key System Installation Manual. The Macrotel manuals for IP Phone are available online for free. You can easily download all the documents as PDF.
Page 21
IMPORTANT SAFETY INSTRWTIONSI Read and understand all instructions Follow all warnings and instructions marked on the product Unplug this product from the wall outlet before cleaning Do not use liquid cleaners or aerosol deaner Use a damp doth for deaning.Do not use this product near water, for example, near a bath tub, wash bowl, kitchen sink, or laundry tub, in a wet basement,Do not olace this oroduct on an unstable cart. stand. or table The product mav fall causjna serious damaae to the Product. Slots...
Page 22
MOUNTING THE CABINET The central unit (KSU) is a single cabinet to be mounted on thewall. ft should be situated so that it is easily accessible, to ease installation and maintenance. At least 12 inches of free space must exist above and below thecabinet. 12 inches are also required on the right side of the cabinet in ord,er to connect the cables. Screw the mounting screws into the wall, 7.5 inches apart, andabout 63 inches from the floor. Allow a bit of the screw to protrude between the wall and the...
Page 23
Plug the power cord into the AC INPUT. Check the following items BEFORE turning on the powerswitch:1) Is the voltage range in the correct position? 115V .SAMP, position is for AC voltage input: 105 VAC - 128 VAC, 50 Hz/60 Hz. 220V .27AMP, position is for AC voltage input: 207 VAC - 253 VAC, 50 Hz160 Hz. 2) Is the “NORMAURESET” switch in the NORMAL position? Now turn on the power switch, and check that the “SYS IND” LED is flashing to indicate the KSU is operating. LED will beginflashing within 15...
Page 24
INSTALLATION OF POWER FAILURElNSTAUAT/ON OF STATIONS TRANSFER PHONE Plug a single line telephone into the jack labeled “PWR FAILURE PHONE”. Plug the amphenol connectors into the station port labeled“STAl TO STA24”, as below. See page 2.8 for wiring andextension numbers. 2-5
Page 25
INSTAKATION OF SMDR AND MODEMINSTALLATION OF ACCESSORIES Plug the male end with DB9 of the cable into the SMDR port andMODEM port in the KSU. See below. 1) External paging: plug the input jack of the amplifier into the earphone jack labeled “EXT PAGE” in the KSU. Modem connection for remote access: Useof a null modem cable is required forthe KSU to modem side.2) Music-on-hold /background music: The KSU automaticallvA null modem cable inverts pins 2 and 3 for a local connection, connect directly to a...
Page 26
INSTALLING THE LOUD BELL To perform the loud bell function, a loud bell and a DC power supply which can provide +12 VDC and 1 AMP DC currentminimum are needed to connect to the KSU. To avoid electro- magnetic interferences, the loud bell should be kept at least 20feet away from the KSU. The voltage and current rating for the loud bell that can be usedare : 100 VAC, 30 VDC, 2 AMP maximum. BA77ERY INSTALLATiONInstall a 24V battery to the KSU, as below, to retain system operation during loss of commercial...
Page 27
DB9 TO DB25 CABLE DES-MALEDE25 - FEMALE PINPIN 18DCD (DATA CARRIER DETECT) 23TD (TRANSMIT DATA) 32RD (RECEIVE DATA)420DSR (DATA SET READY)57GND (SIGNAL) 66DTR (DATA TERMINAL READY)74CTS (CLEAR TO SEND) 85RTS (REQUEST TO SEND)922RI (RING INDICATOR)DISPOSITION OF JACK (AMPHENOL) FOR EXTENSIONS PORTWIRE COLOREXTENSION 1BLUE &WHITE10 IORANGE & WHITE GREEN & WHITE;:4BROWN & WHITE135SLATE & WHITE146BLUE & RED157ORANGE & RED16:GREEN & RED17BROWN & RED1810SLATE & RED1911BLUE & BLACK2012ORANGE & BLACK2113GREEN &...
Page 28
There are two methods of programming. One is using the Remote Programming package, which comes on a diskette,and is used with a PC. The other way is programming through a Display or Executive set. This document explains the second method.Database programming is accessed by entering F# tOnly one person can access database programming at a given time. A password is then entered to gain access to the programmingsection. Database programming is divided into six sections. These are: Set, Line, Call Handling,...
Page 29
SYSTEM TYPE The installer assigns the FCC Registration type with this program section. Either KF or MF can be selected. After accessing database programming Press : Show Press : CHG to change or Press : Next to Accept.System Type : MF SET CATEGORYThe features in the Set Category refer to those features that areprogrammable on a per-set basis. The MT-360 Series is veryflexible in this way - many of the features are programmable byset. Many of these features can be programmed by the individual user,...
Page 30
Default: All lines are accessible by all stations. Press : NEXT Press : SHOW To Change to No,Press : CHG / Line 1 : N To Continue to Next Line,BACK NEXT CHG Press : NEXT/ Line 2 : Y Continue through line 8 j BACK NEXT CHG 1 Press : NEXTFLEXIBLE RING ASSIGNMENT This feature programs which lines will ring at each station. Default: Only the attendant (station 10) receives outside line ringing. Press : NEXT Press : SHOW To Change to No Press : CHG Press : NEXT Continue through line 8. Press : NEXT FORCED...