What’s New in DEFINITY ECS
Release 8.2 Job Aid  555-233-754  Issue 1
April 2000
Networking Enhancements 
265 Networking - ATM 
2
nIntend is that these capabilities will provide administrators with an 
enhanced ability to isolate, diagnose, and correct problems quickly.
Bandwidth Constricted Network 
Example
nCurrently, when a call is to be extended between PNs distributed over an 
ATM network, a CCMS message to provide ringing at the destination is 
sent after the actual SVC setup, but before the SVC...

Page 272

What’s New in DEFINITY ECS
Release 8.2 Job Aid  555-233-754  Issue 1
April 2000
Networking Enhancements 
266 Networking - ATM 
2
nIf all appears normal in the error log, but the latencies are too high, may 
need to upgrade the ATM network to solve the problem. 
NOTE:
fter the problem is fixed, the alarm will clear, but it will take an indeterminate 
amount of time.
nThe ALARM REPORTING OPTIONS form is displayed via the set options 
command.
nThe Off-board ATM Network Alarms field appears regardless of...

Page 273

What’s New in DEFINITY ECS
Release 8.2 Job Aid  555-233-754  Issue 1
April 2000
Networking Enhancements 
267 Networking - ATM 
2
nThe Port is deciphered as: ATxy. 
— xy is the connection number, not the port network number. 
nThe mapping between connection number and port network number can 
be found with the command list atm pnc. 
nThe Aux Data field contains the originating/ destination port network 
numbers. 
— The rightmost two digits are the destination port network number. 
— The remaining leftmost...

Page 274

What’s New in DEFINITY ECS
Release 8.2 Job Aid  555-233-754  Issue 1
April 2000
Networking Enhancements 
268 Networking - ATM 
2
Example
nThe Err Type field is the value 256+destination connection #. 
nThis allows multiple entries of the same port name/ Mtce name pair in the 
error log. 
nIf the error type value was the same for a given port name/Mtce name pair, 
only get 1 entry for that port name/Mtce name pair in the error log. 
nUp to 6 entries of the same port name/Mtce name pair can be stored in...

Page 275

What’s New in DEFINITY ECS
Release 8.2 Job Aid  555-233-754  Issue 1
April 2000
Networking Enhancements 
269 Networking - ATM 
2
nThe Port is deciphered as: ATxyZ. xy is the connection number, not the port 
network number. 
nThe mapping between connection number and port network number can 
be found with the command list atm pnc. 
nThe alarm indicates that at least one path originating from the displayed 
Por t, has exceeded the SVC setup threshold. 
nThe alarm is resolved when SVC setups from all paths...

Page 276

What’s New in DEFINITY ECS
Release 8.2 Job Aid  555-233-754  Issue 1
April 2000
Networking Enhancements 
270 Networking - ATM 
2
T1 401A/E1 402A/E1 403A Synchronization 
Splitters
A DEFINITY ATM-PNC requires network synchronization for DS1 circuit packs not 
to slip relative to the LEC/IXC switches. The ATM switch serves as the sync 
reference source for the DEFINITY. The ATM switch, in turn, derives primary and 
secondary sync. To accomplish this, the most common option is to use 
synchronization...

Page 277

What’s New in DEFINITY ECS
Release 8.2 Job Aid  555-233-754  Issue 1
April 2000
Networking Enhancements 
271 Networking - ATM 
2
Figure 17. 400A synchronization splitter Figure Notes:
1. From network interface
2. Amphenol connection to DEFINITY 
ECS 3. Timing output port (J1) to the ATM switcha
4. Timing output port (J2) to the ATM switcha
a. Ports J1 and  J2 p rovid e id entical DS1 timing  source sig nals to the ATM switc hes. 
The ATM switc h can use two sep arate DS1 timing  signals (one at a time...

Page 278

What’s New in DEFINITY ECS
Release 8.2 Job Aid  555-233-754  Issue 1
April 2000
Networking Enhancements 
272 Networking - ATM 
2
Figure 18. 401A synchronization splitter Figure Notes:
1. Amphenol connector to DEFINITY 
ECS
2. Network timing connection3. Timing alarm lead connection
4. Timing output ports (RJ45) to ATM switch
a
5. Jumpers and capacitors (inside case). See Figure 21 for settings.
a. Ports J1 and  J2 p rovid e id entical DS1 timing  source sig nals to the ATM switc hes. 
The ATM switc h can...

Page 279

What’s New in DEFINITY ECS
Release 8.2 Job Aid  555-233-754  Issue 1
April 2000
Networking Enhancements 
273 Networking - ATM 
2
Figure 19. 402A synchronization splitter Figure Notes:
1. Amphenol connector to DEFINITY 
ECS
2. Network timing connection3. Timing alarm lead connection
4. Timing output ports (RJ45) to ATM switch
a
5. Jumpers and capacitors (inside case). See Figure 21 for settings.
a. Ports J1 and  J2 p rovid e id entical DS1 timing  source sig nals to the ATM switc hes. 
The ATM switc h can...

Page 280

What’s New in DEFINITY ECS
Release 8.2 Job Aid  555-233-754  Issue 1
April 2000
Networking Enhancements 
274 Networking - ATM 
2
Figure 20. 403A synchronization splitter Figure Notes:
1. Amphenol connector to DEFINITY ECS
2. Synchronization source (timing output 
ports) to ATM switch
1
3. Synchronization source (timing output 
ports) to ATM switcha
a. These are id entic al DS1 timing source signals to the ATM switches. The ATM switc h 
can use two separate DS1 timing  sig nals (one at a time from two sep...