Page 111
Troubleshooting 4-24 Problem 8: You receive an error when you shut down Windows. During the shutdown of Windows, it is possible that you may encounter an error pointing to the PWTIMER.DLL file. This problem will be addressed in a later release of the PassageWay Service Provider.
Page 112
Troubleshooting 4-25 PassageWay Adapter LED This section describes the error conditions represented by the LED located next to the Phone jack and Line jack on the PassageWay adapter. Problem 1: The LED is “off.” This indicates that your PassageWay adapter is not receiving power. Make sure the PassageWay adapter is installed properly. Refer to “Installing the PassageWay Adapter” in Chapter 2. If you have verified that the PassageWay adapter is properly connected to your telephone, yet the LED on the...
Page 113
Troubleshooting 4-26 Troubleshooting Connect This section presents some common problems that you might encounter while using Connect. For each problem, a strategy is presented that you can follow to isolate and solve your problem. NOTE: Connect is only present with Windows 95. Connect is not present with Windows NT 4.0 or later. Problem 1: Connect displays the message : This application requires a serial port and terminates. This message indicates that Connect cannot find an available serial port on...
Page 114
Troubleshooting 4-27 Problem 2: Connect displays its Communications Error dialog box within a few seconds after it is run. This message indicates that Connect cannot communicate properly with your telephone. This message can appear for one of the following reasons: „Your PassageWay adapter is not connected properly to your PC serial port and/or your telephone. „Your PassageWay adapter is not receiving power from the PARTNER system. „Connect is administered to use a different serial port than the one to...
Page 115
Troubleshooting 4-28 „Insure your PassageWay adapter is receiving power from the PARTNER system (as indicated by the illumination of the LED). If you have verified that the PassageWay adapter is properly connected to your telephone, yet the LED on the adapter is NOT illuminated, your telephone system wiring may not support the remote powering of adjuncts. If this is the case, you should consult you account representative or authorized dealer to obtain the proper wall supply to power your PassageWay...
Page 116
Troubleshooting 4-29 Failure Code -121 Meaning: The PC and the PassageWay adapter cannot communicate over your serial port. Things to Try: Follow the instructions for Failure Code 111. Failure Code -131, -132, -133, or -135 Meaning: The PC cannot communicate properly with your PassageWay adapter. Things to Try: Try replacing any RS-232 cables or adapters you are using between your PC’s COM port and the PassageWay adapter’s 25-pin connector. Failure Code -134 or -141 Meaning: The PassageWay adapter cannot...
Page 117
Troubleshooting 4-30 Problem 3: Connect will not work on COM ports other than COM1 and COM2. By default, many PCs are not configured to permit the simultaneous use of three or more COM ports. Specifically, most PCs are configured such that COM ports are grouped into pairs: COM1 is paired with COM3, and COM2 is paired with COM4. By default, such PCs permit only one COM port from each pair to be operating at the same time (for example, COM1 with COM2). COM ports within the same pair will usually conflict...
Page 118
Troubleshooting 4-31 The chance of a communications problem depends on your PCs configuration. The PassageWay Service Provider operates at a data rate of 4800 baud, and it relies on Windows to manage the flow of data through your PCs serial port. Depending upon the speed of your PC, the number and type of applications you are using, and various hardware components in your PC configuration, Windows will be able to manage serial communications with varying degrees of effectiveness. If you encounter...
Page 120
Index IN-1 A Anywhere Dialer make calls, 3-9 overview, 3-8 starting, 3-8 using, 3-8 application programming interface, 1-3 area code set for TAPI, 2-42 AT&TCall convert files to Phonebook, 2-50, 3-5 import files to Phonebook, 2-50, 3-5 AutoSizing setting, 2-38 Auto-Task Manager overview, 3-17 starting, 3-18 using, 3-17 C Call Appearance area, 2-38 call appearances set minimum number, 2-38 set number, 2-38 call forwarding troubleshooting, 4-11 caller ID matching, 2-46 conference calls troubleshooting,...