Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Maintenance For Survivable Remote EPN Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 61
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-5 SREPN connections 2 Expansion Interface connections nTN570C Exp ansion Interfac e (EI) c irc uit p ac ks use either the 9823A (multimod e) or the 300A (sing le mod e) transc eivers. NOTE: A new SREPN system inc lud es the TN570C EI c irc uit p ac k. Earlier EI c irc uit pac ks (for examp le, TN570B) are not sup p orted . DS1 CONV...
Page 62
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-6 SREPN connections 2 Transfer sequence to Survive mode Transfer from Normal to Survive mode is automatic and is c ontrolled b y the TN775C Maintenanc e b oard . Fi g u re 2 - 3 shows a schematic of the link switc hing within the TN2301 c irc uit p ac k. Figure 2-3. TN2301 link switching schematic The transfer seq uenc e to Survive mod...
Page 63
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-7 SREPN connections 2 Tab le 2-3 shows the sequenc e of events to transfer to the Survive mod e, the ap p roximate times for eac h event, and the servic e affec ted at eac h stag e. TN2301 (SRSwitch) The SRSwitc h c irc uit p ac k (TN2301) oc c up ies 6 slots in the SRP c ab inet. Fi g u re 2-4 shows the fac ep late switc h and LEDs for...
Page 64
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-8 SREPN connections 2 Figure 2-4. TN2301 faceplate switch and LEDs Faceplate switch Tab le 2-4 ind ic ates the 3 p ositions for the fac ep late switc h and the use for eac h. Table 2-4. Faceplate switch positions and uses Label Position Use RSTR Top Forc es c ontrol to the Release 7r b y switc hing from Survive mod e to Normal mod e 1 1....
Page 65
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-9 SREPN connections 2 SREPN connections Fi g u re 2 - 5 shows a d etailed view of the rear p anel c onnec tors. Figure 2-5. SREPN rear panel - detail scdfsre4 RPY 022398 PI EI TX S.R. SW ITCHEPN B EPN APPN B PPN A TX TX TX RX RX RX RXAUX DCE TERM
Page 66
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-10 SREPN connections 2 Fi g u re 2 - 6 shows the hard ware c onnec tions in the d irec t fib er system. Figure 2-6. Detailed SRP direct fiber connections Figure Notes: 1. Fib er transmit (TX) and rec eive (RX) p airs for A and B c arriers. 2. SRP AUX B25A 25-p air c ab le; max. leng th = 50 ft. (15.25 m): nMajor SRP p ower failure alarm...
Page 67
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-11 SREPN connections 2 Fi g u re 2 - 7 shows the hard ware c onnec tions in the DS1-CONV system. Figure 2-7. Detailed SRP DS1-CONV connections Figure Notes: 1. Fib er transmit (TX) and rec eive (RX) p airs for A and B c arriers. 2. SRP AUX B25A 25-p air c ab le; max. leng th = 50 ft. (15.25m): nMajor SRP p ower failure alarm lead nRemote...
Page 68
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-12 Maintenance procedure 2 Maintenance procedure Sinc e Survive mod e is invoked bec ause of a link failure b etween the Release 7r and an EPN, the maintenanc e strateg y is to: 1.‘‘ Check system status’’ 2.‘‘Rep air the link c onnec tion’’ 3.‘‘Rec onnec t the Release 7r to the EPN’’ 4.‘‘Post-reset check’’ The final sec tions of this c hap...
Page 69
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-13 Maintenance procedure 2 Expansion Interface (TN570C) LED interpretation The Exp ansion Interfac e c irc uit p ac k has red , g reen, and yellow LEDs. The red and g reen LEDs show the stand ard c ond itions: nRed ind ic ates an alarm c ond ition nGreen ind ic ates maintenanc e testing in p rog ress The yellow LED is used to p rovid e...
Page 70
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-14 Maintenance procedure 2 Table 2-6. Expansion Interface circuit pack Yellow LED Flashing States Condition LED On LED Off Fib er Out-of-Frame 1 1. This flashing state c orresp onds to Error Codes 769 and 770 from the Hard ware Error Log and ind icates a failure of Test #238. These error cod es are usually ac c ompanied by Error Cod e...