Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Maintenance For Survivable Remote EPN Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 51
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Installation 1-29 Test the SRP 1 Test the SRP 1. After the SRP is fully ad ministered and the TN2301 switc h (Figure 1-14) is in the AUTO p osition, you are read y to test the SRP. Figure 1-14. TN2301 faceplate switch and LEDs ckdf02fo RPY 022398 BKUP DATA AUTO RSTR AUTO TEST SURVIVE MODE ON
Page 52
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Installation 1-30 Test the SRP 1 Test the survive mode function 1. Type list cabinet and press En te r on the R7r manag ement terminal. Determine whic h EPN is “ watc hed” b y Survivab le Remote eq uip ment b y looking for the lower-c ase “s ” b efore the letters “ EPN” in the Type field as shown in Figure 1-15 . There may b e more than 1 EPN d...
Page 53
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Installation 1-31 Test the SRP 1 3. Type status health and press En te r on the SRP manag ement terminal. The status of the SREPN should b e “ d own.” See Fig ure 1-17 . Figure 1-17. Status health screen (SRP) 4. Plac e a voic e c all from a telep hone on the Release 7r PPN to a telep hone on the SREPN and verify the talk p ath. 5. Physic ally d isc...
Page 54
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Installation 1-32 Test the SRP 1 12. Move the TN2301 switc h to the AUTO p osition. 13. Verify that the SREPN is b ac k in servic e on the Release 7r within 1-2 minutes. 14. Typ e status health and p ress En t e r on the Release 7r management terminal. The status of the SREPN should b e “ up .” 15. Typ e status health and press En te r on the SRP...
Page 55
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Installation 1-33 Upgrade the SRP 1 Verify the SRP status 1. Verify that the TN2301 switc h is in the AUTO p osition and the g reen AUTO LED is on. 2. Verify that the red BKUP LED on the TN2301 is off. 3. Verify that the red SURVIVE MODE ON LED is off. 4. Verify that the yellow DATA LED is on. 5. Verify that the g reen LED on the EPN TN775C maintenanc e...
Page 56
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Installation 1-34 Upgrade the SRP 1
Page 57
SREPN Maintenance 2-1 Before starting to troubleshoot 2 DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 2 SREPN Maintenance Before starting to troubleshoot NOTE: When the SRP is in Normal mod e, the Expansion Interfac e c irc uit p ac k’s yellow LED flashes (see Tab le 2-6 ). This is normal. The links to its c ounterpart in the R7r are d own and are not re-estab lished until the SRP g oes into Survive mod...
Page 58
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-2 SREPN connections 2 Fi g u re 2 - 1 shows an examp le of the essential hard ware c onnec tions for the Survivab le Remote EPN over DS1-CONV fac ilities. Figure 2-1. Survivable Remote EPN hardware connections over DS1-CONV facilities !CAUTION: Only the TN1654 DS1 CONV c irc uit p ac k c an b e used for DS1-CONV-remoted SREPN systems. The...
Page 59
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-3 SREPN connections 2 Figure 2-2. Front view - SRP cabinet Required and optional circuit packs Survivable Remote Processor (SRP) Tab le 2-1 lists the required and op tional c irc uit p ac ks in the SRP: Figure Notes: 1. Proc essor (TN790B) 2. )Proc essor interfac e (TN765) 3. Network/Pac ket Control (TN794) or Network c ontrol (TN777B -...
Page 60
DEFINITY® Enterprise Communications Server Release 7 Installation and Maintenance for Survivable Remote EPN 555-233-102 Issue 2 June 1999 SREPN Maintenance 2-4 SREPN connections 2 Survivable Remote EPN Tab le 2-2 lists the required and op tional c irc uit p ac ks in the SREPN: Interfacing circuit packs The Survivab le Remote eq uip ment c an op erate throug h: n‘‘Exp ansion Interfac e c onnec tions’’ n‘‘DS1 CONV c onnec tions’’ TN2182B Tone/Cloc k TN771D Maintenance/Test Used only when p acket b...