Home
>
Lucent Technologies
>
Communications System
>
Lucent Technologies DEFINITY® Enterprise Communication Server Release 8.2 Reports Guide
Lucent Technologies DEFINITY® Enterprise Communication Server Release 8.2 Reports Guide
Here you can view all the pages of manual Lucent Technologies DEFINITY® Enterprise Communication Server Release 8.2 Reports Guide. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 261
DEFINITY Enterprise Communication Server Release 8.2 Reports Guide 555-233-505 Issue 1 April 2000 Processor Occupancy Reports 4-11 The Busiest-Interval Command 4 4. Refer to the list measurements communications-links rep ort to d etermine if any of the links are rec eiving an ab normal amount of traffic . 5. Chec k with the users to d etermine if a c ertain feature(s) is used heavily d uring the id entified time interval. 6. Refer the p rob lem to maintenanc e p ersonnel with the sug g estion...
Page 262
DEFINITY Enterprise Communication Server Release 8.2 Reports Guide 555-233-505 Issue 1 April 2000 Processor Occupancy Reports 4-12 Processor Occupancy Busiest-Interval Measurements Report 4 Screen 4-4. Processor Occupancy Busiest-Interval Measurements Report NOTE: The field s on this rep ort are the same as on the summary rep ort. However, the d ata is c alc ulated over 3-minute intervals rather than 1-hour intervals. Using the Busiest-Interval Report to Resolve Problems The following list id...
Page 263
DEFINITY Enterprise Communication Server Release 8.2 Reports Guide 555-233-505 Issue 1 April 2000 Processor Occupancy Reports 4-13 The Pktint Command 4 After a serious p erformanc e p rob lem is d etec ted and c orrec ted, use the clear measurements occupancy busiest-intervals c ommand and c lear the log of b usiest entries. This allows attention to b e foc used on any c urrent performanc e problems. NOTE: Th e clear measurements occupancy busiest-intervals c ommand should only b e used...
Page 264
DEFINITY Enterprise Communication Server Release 8.2 Reports Guide 555-233-505 Issue 1 April 2000 Processor Occupancy Reports 4-14 Processor Occupancy Pktint Report 4 Screen 4-5. Processor Occupancy Pktint Report Table 4-2. Processor Occupancy Pktint Report Field Description Meas Hour Measurement Hour. The starting hour in whic h the measurements are taken. PKT-INTN Occ Packet-Interface Occupancy. Where N is either 1, 2, or 3, representing eac h of the 3 PKT-INT b oard s. The perc ent oc c up...
Page 265
DEFINITY Enterprise Communication Server Release 8.2 Reports Guide 555-233-505 Issue 1 April 2000 Processor Occupancy Reports 4-15 The Communications Links Command 4 The Communications Links Command This sec tion d esc rib es the Proc essor Oc c up anc y Communic ations Links command. When to Use the Communications Links Command The main func tion of the c ommunic ations links c ommand is to: nObtain a rep ort that fac ilitates the monitoring of traffic over the p roc essor interfac e links...
Page 266
DEFINITY Enterprise Communication Server Release 8.2 Reports Guide 555-233-505 Issue 1 April 2000 Processor Occupancy Reports 4-16 Processor Occupancy Communications Link Measurements Report 4 Screen Screen 4-6 and Screen 4-7 show typ ic al outp ut for the Proc essor Oc c up anc y Communic ation Link Measurements rep ort. The time and d ate the rep ort is requested displays at the top right. Table 4-3 d esc rib es the data fields p resented in the Proc essor Oc c up anc y Communic ations Link...
Page 267
DEFINITY Enterprise Communication Server Release 8.2 Reports Guide 555-233-505 Issue 1 April 2000 Processor Occupancy Reports 4-17 Processor Occupancy Communications Link Measurements Report 4 The Proc essor Oc c up anc y Communic ation Link Measurements rep orts for eac h c ustomer ap p lic ation varies sig nific antly sinc e a p artic ular link on one switc h may serve a d ifferent func tion than the same link for another switc h. Furthermore, what is c onsid ered to be normal link traffic for...
Page 268
DEFINITY Enterprise Communication Server Release 8.2 Reports Guide 555-233-505 Issue 1 April 2000 Processor Occupancy Reports 4-18 Mapping Links to Applications 4 Mapping Links to Applications Command To see what ap p lic ations are running on the links: 1. Type display communications-interface links and press RETU RN. Screen Screen 4-8 shows typ ic al outp ut for the Proc essor Oc c up anc y Interfac e Links rep ort for the G3r, G3si and G3c si systems. Table 4-4 describes the data fields p...
Page 269
DEFINITY Enterprise Communication Server Release 8.2 Reports Guide 555-233-505 Issue 1 April 2000 Processor Occupancy Reports 4-19 Mapping Links to Applications 4 Table 4-4. Processor Occupancy Interface Links report Field Description LinkA display-only field . Ind ic ates the interfac e link numb er that c onnec ts to another nod e in a DCS network, a Messag e Server, CMS, ISDN Gateway, or AUDIX. Interfac e Links always terminate on a p ort in a PGATE c irc uit pac k for R5r and later c onfig...
Page 270
DEFINITY Enterprise Communication Server Release 8.2 Reports Guide 555-233-505 Issue 1 April 2000 Processor Occupancy Reports 4-20 Mapping Links to Applications 4 Data Analysis Guidelines The following guid elines are intend ed to show an easy method for determining whether c urrently rep orted d ata is ac c ep tab le or not. These g uid elines represent the minimum you should d o to verify the rec orded measurement values are c onsistent with exp ec ted and historic values. Perform ad d...