Home > Lucent Technologies > Communications System > Lucent Technologies DEFINITY® Enterprise Communication Server Release 8.2 Reports Guide

Lucent Technologies DEFINITY® Enterprise Communication Server Release 8.2 Reports Guide

Here you can view all the pages of manual Lucent Technologies DEFINITY® Enterprise Communication Server Release 8.2 Reports Guide. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 191

DEFINITY Enterprise Communication Server Release 8.2
Reports Guide  555-233-505  Issue 1
April 2000
Traffic Data Analysis 
3-149 Traffic Summary Report 
3
Traffic Summary Report
The Traffic  Summary Rep ort p rovid es an overview of system p erformanc e. 
Summarized  in the rep ort are p eak hour c all p roc essing  and  system 
manag ement oc c up anc y, p eak hour b loc king for TDM time slots on eac h p ort 
network, p eak hour b loc king  for p ort network links and  switc h node links, and  the 
p...

Page 192

DEFINITY Enterprise Communication Server Release 8.2
Reports Guide  555-233-505  Issue 1
April 2000
Traffic Data Analysis 
3-150 Traffic Summary Report 
3
Screen
Screen 3-53, Screen 3-54 and  Screen 3-55 show typ ic al sc reens for the Traffic  
Su m m a r y  Re p o r t s.  Table 3-44
 d esc rib es the d ata field s p resented  in these 
sc reens.
Screen 3-53. Traffic Summary Report 
— Page 1
Screen 3-54. Traffic Summary Report 
— Page 2
list measurements summary
Switch Name: Cust_Switch_Name...

Page 193

DEFINITY Enterprise Communication Server Release 8.2
Reports Guide  555-233-505  Issue 1
April 2000
Traffic Data Analysis 
3-151 Traffic Summary Report 
3
Screen 3-55. Traffic Summary Report — Page 3
Table 3-44. Traffic Summary Report 
Field Description
Meas Hour
Measurement Hour. The starting  time (using  the 24-hour c loc k) 
of the hour d uring whic h the d ata was rec ord ed .
Static 
Occupancy 
Static  Oc c upanc y. The p erc entag e of p roc essor oc c up anc y 
required by background processes in...

Page 194

DEFINITY Enterprise Communication Server Release 8.2
Reports Guide  555-233-505  Issue 1
April 2000
Traffic Data Analysis 
3-152 Traffic Summary Report 
3
High PN 
BlkHig hest Port Network Bloc king. The highest percent of TDM 
time slot seizure failures d ue to insuffic ient time slots for any 
PN. This is time c oinc id ent with Peak Total Bloc king  ab ove. It 
is c omp uted  as follows:
Hig hest PN Blk =  (TDM Bloc kag e x 100) / TDM Pegs
High 
PNL/SNL 
BlkHighest Port Network Link/Switch Node Link...

Page 195

DEFINITY Enterprise Communication Server Release 8.2
Reports Guide  555-233-505  Issue 1
April 2000
Traffic Data Analysis 
3-153 Traffic Summary Report 
3
Wideband 
Trunk 
GroupThe time stamp that ind ic ates when the Wid eb and  Trunk 
Group Measurement Selection sc reen was last updated. This 
time stamp  is retrieved  when the measurements for the 
Wid eb and  Trunk Group  Hourly Rep ort are c ollec ted eac h 
hour.
Coverage 
Path The time stamp that ind ic ates when the Coverag e 
Measurement Selec...

Page 196

DEFINITY Enterprise Communication Server Release 8.2
Reports Guide  555-233-505  Issue 1
April 2000
Traffic Data Analysis 
3-154 Trunk Group Reports 
3
Trunk Group Reports
This sec tion d esc rib es the traffic , outag e, p erformanc e, status, c all-b y-c all, and  
lig htly used  rep orts for Trunk Group s, and  d esc rib es the valid ation and  analysis 
of the d ata p rovid ed  in the rep orts.
Trunk Group Summary Report
The Trunk Group  Summary Rep ort g ives traffic  measurements for all trunk g...

Page 197

DEFINITY Enterprise Communication Server Release 8.2
Reports Guide  555-233-505  Issue 1
April 2000
Traffic Data Analysis 
3-155 Trunk Group Summary Report 
3
Command
To d isp lay the Trunk Group  Summary rep ort:
1. Type list measurements trunk-group summary  [print/schedule] 
and  p ress 
RETU RN. 
Required Fields: There is one req uired  field  for this c ommand  — 
yesterday-peak/today-peak/last-hour
. 
nEn t e r  yesterday-peak 
to list a summary of the trunk g roup  ac tivity 
for yesterd ay’s peak...

Page 198

DEFINITY Enterprise Communication Server Release 8.2
Reports Guide  555-233-505  Issue 1
April 2000
Traffic Data Analysis 
3-156 Trunk Group Summary Report 
3
Table 3-45. Trunk Group Summary Report 
Field Description
Peak Hour 
for All 
Trunk 
GroupsThe hour d uring  the sp ec ified  d ay with the larg est total usag e, 
when summed  over all trunk g roup s. Peak hour and  busy hour 
are synonymous. With c onventional traffic  theory d ata 
analysis, there are two method s for d etermining  the p eak...

Page 199

DEFINITY Enterprise Communication Server Release 8.2
Reports Guide  555-233-505  Issue 1
April 2000
Traffic Data Analysis 
3-157 Trunk Group Summary Report 
3
Grp TypeGroup Type. The typ e of trunk in the trunk g roup . The system 
monitors/measures the following  trunk types: 
nAc c ess Tie Trunk (Access
) 
nAd vanc ed  Private Line Termination (aplt
) 
nCentral Offic e (co
) 
nPub lic  Network Servic e Customer Provid ed  Eq uip ment 
(cpe
) 
nDirec t Inward  Dialing  (did
) 
nDirec t Inward /Outward...

Page 200

DEFINITY Enterprise Communication Server Release 8.2
Reports Guide  555-233-505  Issue 1
April 2000
Traffic Data Analysis 
3-158 Trunk Group Summary Report 
3
Total 
Usage1Total usag e (in CCS) for all trunks in the trunk group . 
Rep resents the total time the trunks are b usy (with c alls) 
d uring  the one-hour measurement p eriod . Total usag e 
measures eac h time a trunk is seized  for use b y an inc oming 
c all (whether it is p ic ked  up  or not) or an out g oing  c all (only 
after d ig its...
Start reading Lucent Technologies DEFINITY® Enterprise Communication Server Release 8.2 Reports Guide

Related Manuals for Lucent Technologies DEFINITY® Enterprise Communication Server Release 8.2 Reports Guide

All Lucent Technologies manuals