Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation And Test For Multi-Carrier Cabinets Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 371
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Option Switch Settings B-7 Call Detail Recording Option Settings B Call Detail Recording Option Settings The interfac e between the system and CDR eq uip ment may b e 1 of the following : nData Module — rec ommend ed op tion setting s are shown in Ta b l e B - 3. nMod em — rec ommend ed op tion setting s are in mod em vend or d oc ument nTN726 Data Line c irc uit p ac k and an Async hronous...
Page 372
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Option Switch Settings B-8 Call Detail Recording Option Settings B Ad ministration p roc ed ures for CDR eq uip ment are p rovid ed in DEFINITY Enterp rise Communic ations Server Release 8 Ad ministrator’s Guid e. Table B-4. 572 Printer Used with Management Terminal, CDR, or Journal Printer Function Function Name Menu Menu Status 01 FORM LENGTH 09 11 02 LPI 01 6 03 CPI 01 10 04 LQ or NLQ 01 LQ...
Page 373
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Option Switch Settings B-9 TN760D Tie Trunk Option Settings B TN760D Tie Trunk Option Settings The TN760D Tie Trunk c irc uit p ac k interfac es b etween four tie trunks and the TDM b us. Two tip and ring p airs form a 4-wire analog transmission line. An E and M p air are DC sig naling lead s used for c all setup . The E-lead rec eives signals from the tie trunk and the M-lead...
Page 374
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Option Switch Settings B-10 TN760D Tie Trunk Option Settings B Figure B-2. TN760D Tie Trunk Circuit Pack (Component Side) Table B-6. Signaling Type Summary Signaling Type Transmit (M-Lead) Receive (E-Lead) On-Hook Off-Hook On-Hook Off-Hook Type I Standard ground battery open 1/battery 1. An op en c irc uit is p referred instead of b attery voltag e. ground Type I Compatible open 1/b attery g...
Page 375
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Option Switch Settings B-11 TN464E/F Option Settings B TN464E/F Option Settings The TN464E/F DS1/E1 Interfac e - T1/E1 c irc uit p ac k interfac es b etween a 24 or 32 c hannel Central Offic e/ISDN or tie trunk and the TDM b us. Set the switc hes on the c irc uit p ac k to selec t b it rate and imp edanc e matc h. See Ta b l e B - 8 and Fig ure B -3. Table B-7. TN760D Option Switch...
Page 376
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Option Switch Settings B-12 TN464E/F Option Settings B Figure B-3. TN464E/F Option Settings Figure Notes 1. Bac kp lane Connec tors 2. 24/32 Channel Selec tor 3. 75/120 Ohm Selec tor 4. Fac ep late 5. 32 Channel6. 120 Ohm (shown selec ted ) 7. 24 Channel (shown selec ted ) 8. 75 Ohm 9. Connec tor 10. TN464E/F DS1/E1 Interfac e Circ uit Pac k 3 8 4 9 5 10 1 6 2 7
Page 377
Cable Ductwork C-1 C DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 C Cable Ductwork The c ab le d uc twork is assembled from various g roup numb ers from ED-1E465 (fac ia p aneling to c over the I/O d uc ts is assemb led from ED-1E464). The assemb ly, installed after the c ab inets have b een installed , p rovid es d uc ts for three typ es of c ab les: interc ab inet c ab les, I/O c ables (tip and ring ), and AC power cables. DC...
Page 378
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Cable Ductwork C-2 C Eq uip ment room layout and exp ec ted g rowth d etermines whic h method to use. Installation of an overhead rac k is c overed b y Cab le Rac ks (800-614-157). NOTE: Install all sc rews in all ap p rop riate p lac es to c omply with elec tromag netic interferenc e (EMI) req uirements for shield ing . Figure C-1. Typical Layout of Assembled Ductwork Installation This d...
Page 379
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Cable Ductwork C-3 C Inventory the materials rec eived and mark a c opy of the floor p lan with the loc ation of eac h g roup numb er to b e installed . Hard ware used to assemb le eac h item is pac kag ed with the ind ivid ual g roup s. Ta b l e C - 1 shows the availab le g roup numb ers and a brief d esc rip tion of eac h g roup. Some d uc ts are equip p ed with c overs whic h should...
Page 380
DEFINITY ECS Release 8.2 Installation and Test for Multi-Carrier Cabinets 555-233-114 Issue 1 April 2000 Cable Ductwork C-4 C Install the various c able d uc ts in the order shown in Ta b l e C - 2. Fi g u re C - 2 shows an overhead view of a typ ic al d uc twork installation. !WA R N I N G : To prevent d amag e to the c ab inet c irc uitry or c ab les, plac e c ard b oard or eq uivalent in the c ab le d uc ts to c atc h any metal filing s that may fall from the self-threading sc rews. 31...