Page 991
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 967 Trunk Group 17 CDR FEAC Unrestricted Call List Trunk Group Use the Trunk Group screen to set basic characteristics for every type of trunk group and to assign ports to the group. This section lists and describes all the fields you might see on the screen. Many fields are dependent on the settings of other fields and only appear when certain values are entered in other fields on the screen. For...
Page 992
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 968 Trunk Group 17 Field descriptions for page 1 The figure below shows a common configuration for page 1 of the Trunk Group screen when the Group Type field is tie. This screen is only an example, and the fields shown below may change or disappear according to specific field settings. Screen 210. Tie Trunk Group Group Number This field displays the group number assigned when the trunk group was added....
Page 993
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 969 Trunk Group 17 Group Type Enter the type of trunk group. Valid entries Usage Access Use access trunks to connect satellite switches to the main switch in Electronic Tandem Networks (ETN). Access trunks do not carry traveling class marks (TCM) and thus allow satellite callers unrestricted access to out-dial trunks on the main switch. Allows Inband ANI. APLT Advanced Private Line Termination (APLT)...
Page 994
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 970 Trunk Group 17 ISDN Use ISDN trunks when you need digital trunks that can integrate voice, data, and video signals and provide the bandwidth needed for applications such as high-speed data transfer and video conferencing. ISDN trunks can also efficiently combine multiple services on one trunk group. You cannot enter isdn unless the ISDN-PRI field, the ISDN-BRI Trunks field, or both have been...
Page 995
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 971 Trunk Group 17 CDR Reports NOTE: For ISDN trunk groups, the Charge Advice field affects CDR information. For CO, DIOD, FX, and WATS trunk groups, the Analog PPM field affects CDR information. Group Name COR Valid entries Usage y All outgoing calls on this trunk group will generate call detail records. If the Record Outgoing Calls Only field on the CDR System Parameters screen is n, then incoming...
Page 996
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 972 Trunk Group 17 Tip: Remember that facility restriction levels (FRL) are assigned to classes of restriction. Even if 2 trunk groups have classes of restriction that allow a connection, different facility restriction levels may prevent operations such as off-net call forwarding or outgoing calls by remote access users. TN Tip: Double-check your entry. If you accidentally enter an unassigned tenant...
Page 997
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 973 Trunk Group 17 Protocol Type This field specifies the type of line signaling protocol used for DID and DIOD trunk groups. This field appears when the Country field is 15 and is used only by trunk group members administered on a TN2199 or TN464D vintage 3 or later circuit pack. Direction This field appears for all trunk groups except DID and CPE. Outgoing Display This field allows display phones to...
Page 998
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 974 Trunk Group 17 Trunk Signaling Type This field controls the signaling used by members in private network trunk groups, mainly in Italy, Brazil, and Hungary. This field appears if the Group Type is access, aplt, diod, rlt, tandem, or tie. Entries in this field affect which timers appear on the Administrable Timers page. Valid entries Usage cont (continuous)E&M trunks in Italy, Brazil, and Hungary...
Page 999
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 975 Trunk Group 17 Dial Access This field controls whether users can route outgoing calls through an outgoing or two-way trunk group by dialing its trunk access code. Allowing dial access does not interfere with the operation of AAR/ARS. !SECURITY ALERT: Calls dialed with a trunk access code over WATS trunks bypass AAR/ARS and aren’t restricted by facility restriction levels. For security, you may want...
Page 1000
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 976 Trunk Group 17 Busy Threshold Use this field if you want attendants to control access to outgoing and two-way trunk groups during periods of high use. When the threshold is reached and the warning lamp for that trunk group lights, the attendant can activate trunk group control: internal callers who dial out using a trunk access code will be connected to the attendant, and the attendant can...