Home > Lucent Technologies > Communications System > Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Administrators Guide

Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Administrators Guide

Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Administrators Guide. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 1041

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1
April 2000
Screen reference 
1017 Trunk Group 
17
Normal Outgoing Seize Send (msec)
This field appears only if the Trunk Signaling Type field is 
dis and the trunk group 
Direction field is 
two-way or outgoing. Only TN2140 ports receive this timer.
Release Ack Send (msec)
After your switch receives a forward release signal, it must send a forward release 
acknowledgment signal. This field appears only if the Trunk Signaling Type field...

Page 1042

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1
April 2000
Screen reference 
1018 Trunk Group 
17
Outgoing Disconnect Send (msec)
This field is administrable only if the Trunk Signaling Type field is 
dis and the 
trunk group Direction field is 
two-way or outgoing. Only TN2140 ports receive 
this timer.
Seize Ack Send (msec)
This field appears only if the Trunk Signaling Type field is 
dis and the trunk group 
Direction field is 
incoming or two-way. Only TN2140 ports receive this...

Page 1043

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1
April 2000
Screen reference 
1019 Trunk Group 
17
Pause (msec)
THis field is administrable only if the Trunk Signaling Type field is blank. All 
CO, DIOD, and tie circuit packs that accept administrable timers accept this timer. 
However, this timer is sent only to the following circuit packs: TN464B (or later), 
TN767, TN436B, TN459B, TN2146, TN2199, and TN2242, and TN429 and 
TN2184 ports in a DID trunk group.
PPS
NOTE:
The TN439,...

Page 1044

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1
April 2000
Screen reference 
1020 Trunk Group 
17
Break (msec)
PPM
For CO, DIOD, FX, PCOL, and WATS trunks. This field appears when the 
Direction field is 
outgoing or two-way.
Frequency
This field identifies the PPM pulse frequency(ies) sent by the public network. It 
appears if the Direction field is 
outgoing or two-way and PPM is y. Circuit packs 
can detect up to three different frequencies, (12kHz, 16kHz, and 50Hz), plus two...

Page 1045

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1
April 2000
Screen reference 
1021 Trunk Group 
17
Field descriptions for page 4
This screen appears when the Direction field on Page 1 is 
outgoing or two-way 
and the ATMS field is 
y on the Feature-Related System Parameters screen.
The figure below shows a common configuration for page 4 of the Trunk Group 
screen when the Group Type field is 
co. This screen is only an example, and the 
fields shown below may change or disappear...

Page 1046

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1
April 2000
Screen reference 
1022 Trunk Group 
17
TTL Type
Specifies the type of terminating test line (TTL) selected for testing trunks. The 
TTL type determines what ATMS tests can be completed and thus which 
threshold values need to be administered.
The following table explains the differences between types of terminating test 
lines:
The far-end switch containing the TTL may be any of the following:
nSystem 85 R2 switch, equipped...

Page 1047

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1
April 2000
Screen reference 
1023 Trunk Group 
17
nSystem 85 R2 switch, equipped with the Analog/Digital Facility Test 
Circuit (ADFTC, SN261)
nDIMENSION FP8, equipped with the Analog Facility Test Circuit (AFTC, 
ZLC-12)
nCentral Office switches, equipped with various TTL equipment that 
provide 100, 102, or 105 test line capabilities (56A)
Other vendors’ switches may be supported if compatible test lines are provided by 
these...

Page 1048

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1
April 2000
Screen reference 
1024 Trunk Group 
17
Trunk Vendor 
Trunk Contact 
Trunk Length
This field is not required. Since noise on a trunk increases with the length of the 
trunk, however, this information may be useful,
Marginal Threshold - Min -1004 Hz Loss
Marginal Threshold - Max - 1004 Hz Loss
Valid entries Usage
0 to 22 
alphanumeric 
charactersEnter the name of the vendor providing service over this trunk 
group (the company...

Page 1049

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1
April 2000
Screen reference 
1025 Trunk Group 
17
Unacceptable Threshold - Min - 1004 Hz Loss
Unacceptable Threshold - Max - 1004 Hz Loss
Marginal Threshold - -Dev - 404 Hz Loss
Marginal Threshold - +Dev - 404 Hz Loss
Unacceptable Threshold - -Dev - 404 Hz
Valid entries Usage
-2
 to 21Enter the minimum signal loss allowed for a 1004 Hz test tone 
(in dB) before a trunk is reported as unacceptable. A larger dB 
value is more...

Page 1050

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1
April 2000
Screen reference 
1026 Trunk Group 
17
Unacceptable Threshold - +Dev - 404 Hz
Marginal Threshold - -Dev - 2804 Hz
Marginal Threshold - +Dev - 2804 Hz
Unacceptable Threshold - -Dev - 2804 Hz
Unacceptable Threshold - +Dev - 2804 Hz
Valid entries Usage
0
 to 9Enter the maximum positive deviation of measured loss at 404 
Hz from the 1004 Hz test tone loss level (in dB) allowed 
before reporting a trunk as unacceptable. Smaller dB...
Start reading Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Administrators Guide

Related Manuals for Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Administrators Guide