Home > Lexmark > Printer > Lexmark C760 Service Manual

Lexmark C760 Service Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Lexmark C760 Service Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 166 Lexmark manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 466
    							
    Connector locations5-9
      5060-4xx
    J7 Yellow Printhead Mirror Motor 1 FUSE24V 2 Ground
    3 Ground
    4 +5 V dc (through fuse F12)
    5 Y MMSTART
    6 Y HSYN-SOS
    7 Y MMLOCK
    8 Ground
    9 Y MMREF
    10 N/C
    J8 Yellow and Cyan Video to 
    Printheads 1C_DATA+
    2 Ground
    3C_DATA-
    4 Y_THERMISTOR
    5 Ground
    6Y_LENA
    7 +5 V dc (through fuse F12 and safety switches at 
    J10)
    8 Ground
    9C_LPWM
    10 Y_LADJ
    11 Ground
    12 Ground
    13 C_LADJ
    14 Y_LPWM
    15 Ground
    16 +5 V dc (through fuse F12 and safety switches at  J10)
    17 C_LENA
    18 Ground
    19 C_THERMISTOR
    20 Y_DATA-
    21 Ground
    22 Y_DATA+
    See  “System board - non-network” on page 5-6  or “System board - network” on page 5-7 .
    Connector Pin no. Signal 
    						
    							
    5-10Service Manual
    5060-4
    xx   
    J9 Printhead - Cyan Mirror Motor 1 FUSE24V 2 Ground
    3 Ground
    4 +5 V dc (through fuse F12)
    5C_MMSTART
    6C_HSYN_SOS
    7C_MMLOCK
    8 Ground
    9C_MMREF
    10 N/C
    J10 Cover Open Switch 1 +5 V dc (direct from low voltage power supply)
    2 Ground
    3 VDO_ERR (+5 V dc to J8 and J12)
    J11 Printhead - Magenta Mirror Motor 1 FUSE24V
    2 Ground
    3 Ground
    4V_V5FUSE
    5 M_MMSTART
    6 M_HSYN-S0S
    7 M_MMLOCK
    8 Ground
    9 M_MMREF
    10 N/C
    See “System board - non-network” on page 5-6  or “System board - network” on page 5-7 .
    Connector Pin no. Signal 
    						
    							
    Connector locations5-11
      5060-4xx
    J12 Printhead - Black/Magenta Video 1 K_DATA+ 2 Ground
    3K_DATA-
    4 M_THERMISTOR
    5 Ground
    6M_LENA
    7 +5 V dc (through fuse F12 and safety switches at J10)
    8 Ground
    9K_LPWM
    10 M_LADJ
    11 Ground
    12 Ground
    13 K_LADJ
    14 M_LPWM
    15 Ground
    16 +5 V dc (through fuse F12 and safety switches at  J10)
    17 K_LENA
    18 Ground
    19 K_THERMISTOR
    20 M_DATA-
    21 Ground
    22 M_DATA+
    J13 Printhead - Black Mirror Motor 1 FUSE24V
    2 Ground
    3 Ground
    4 +5 V dc (through fuse F12)
    5K_MMSTART
    6 K_HSYN-SOS
    7K_MMLOCK
    8 Ground
    9K_MMREF
    10 N/C
    See “System board - non-network” on page 5-6  or “System board - network” on page 5-7 .
    Connector Pin no. Signal 
    						
    							
    5-12Service Manual
    5060-4
    xx   
    J14 Developer HVPS 1 -CART_METER_K_IN 2 K_AC_BIAS_ENABLE (active low)
    3 SC_K_CHIP
    4N/C
    5 K_DEV_PWM_OUT
    6 -CART_METER_M_IN
    7 K_CHARGE_PWM_OUT
    8 CMY_CHARGE_PWM_OUT
    9 SC_M_CHIP
    10 N/C
    11 -CART_METER_C_IN
    12 CMY_AC_BIAS_ENABLE (active low)
    13 SC_C_CHIP
    14 N/C
    15 M_DEV_PWM_OUT
    16 -CART_METER_Y_IN
    17 C_DEV_PWM_OUT
    18 Y_DEV_PWM_OUT
    19 SC_Y_CHIP
    20 N/C
    21 Ground
    22 +24V_SWITCHED
    23 N/C
    24 N/C
    See “System board - non-network” on page 5-6  or “System board - network” on page 5-7 .
    Connector Pin no. Signal 
    						
    							
    Connector locations5-13
      5060-4xx
    J15 Transfer HVPS 1 ITU_TX_ENA_OUT (active low) 2 ITU_TX_CUR_PWM_OUT
    3 ITU_SERVO_IN
    4 ITU_TX_PWM_OUT
    5 CMY_TX_ENA_OUT (active low)
    6 K_SERVO_IN
    7 K_TX_PWM_OUT
    8 C_SERVO_IN
    9 C_TX_PWM_OUT
    10 M_SERVO_IN
    11 Y_TX_PWM_OUT
    12 Y_SERVO_IN
    13 M_TX_PWM_OUT
    14 Ground
    15 +24V_SWITCHED
    16 N/C
    J16 Option DRAM Socket
    J17 Not Used
    J 1 8 Pa ra ll e l Po r t
    J19 Not Used
    J20 ITU/TPS Autoconnect 1 N/C
    2 ITU_I2C_DATA
    3 +3.3V dc (Through fuse F13)
    4 TPS_GAIN_OUT
    5ITU_TEMP
    6 BELT_HOLE 1 N/C
    7 Ground
    8 Ground
    9 ITU_I2C_CLK
    10 +24V_SWITCHED
    11 TPS_LED_ON_OUT
    12 TONER_PATCH_OUT
    13 N/C
    14 BELT_HOLE 2
    15 +5V_SWITCHED
    See “System board - non-network” on page 5-6  or “System board - network” on page 5-7 .
    Connector Pin no. Signal 
    						
    							
    5-14Service Manual
    5060-4
    xx   
    J21 S2/Narrow Media/Prism/
    MPF Sensor 1 Ground
    2 +5V dc S2 (switched)
    3 NARROW_MEDIA_IN
    4 PAPERPATH_S2_IN
    5 +5 V dc NM (switched)
    6 Ground
    7 Ground
    8 +5 V dc PRISM (switched)
    9 PRISM_SENSOR_IN
    10 PRISM_LED_VOLT
    11 Ground
    12 +5 V dc MPF (switched)
    13 MPF_FEED_OUT_IN
    14 N/C
    J22 INA Card Socket
    J23 Registration (staging) Motor 1 +5V_SWITCHED 2 STAGING_ENC
    3 Ground
    4N/C
    5 STAGING_OUT_2 (+24 V dc in standby)
    6 STAGING_OUT_1(+24 V dc in standby)
    J24 Optional hard disk drive
    J25 Autocomp Motor 1 +5 V dc Paper level (switched) 2 +5V_SWITCHED
    3 PAPER_OUT_IN
    4 AUTOCOMP_ENC
    5 PAPER_LOW_IN
    6 Ground
    7 Ground
    8 Ground
    9 AUTOCOMP_OUT1 (+24 V dc in standby)
    10 AUTOCOMP_OUT2 (+24 V dc in standby)
    J26 Ethernet port
    J27 Not Used
    J28 Cover Open Switch
    (+24V dc switched) 1 +24V To Cover Open Switch
    2 +24V dc Switched
    See 
    “System board - non-network” on page 5-6  or “System board - network” on page 5-7 .
    Connector Pin no. Signal 
    						
    							
    Connector locations5-15
      5060-4xx
    J29 Fuser Stepper Motor/
    Yellow BLDC Motor 1Y_ON_OUT
    2 FUSER_ON_OUT (Fuser current I0)
    3 +5V dc (Through fuse F8)
    4 +5V dc (Through fuse F8)
    5Y_DIR_OUT
    6 FUSER_DIR_OUT (Fuser phase B)
    7 +24V _Y_AND_FUSER (Through fuse F3)
    8 +24V_Y_AND_FUSER (Through fuse F3)
    9 Ground
    10 Ground
    11 Y_CLK_OUT
    12 FUSER_CLK_OUT (Fuser Phase A)
    13 Y_HALL_IN
    14 FUSER_HALL_IN (Fuser Current I1)
    15 N/C
    16 Ground
    J30 ITU/Black BLDC Motors 1 K_ON_OUT
    2ITU_ON_OUT
    3 +5V dc (Through fuse F8)
    4 +5V dc (Through fuse F8)
    5K_DIR_OUT
    6 ITU_DIR_OUT
    7 +24V_K_AND_ITU (Through fuse F4)
    8 +24V_K_AND_ITU (Through fuse F4)
    9 Ground
    10 Ground
    11 K_CLK_OUT
    12 ITU_CLK_OUT
    13 K_HALL_IN
    14 ITU_HALL_IN
    15 N/C
    16 N/C
    J31 Fuser Fan 1 FAN1_STALL_IN 2 Ground
    3 FAN1_CNTRL
    4 +24V_LEFTSIDE
    5 Ground
    See “System board - non-network” on page 5-6  or “System board - network” on page 5-7 .
    Connector Pin no. Signal 
    						
    							
    5-16Service Manual
    5060-4
    xx   
    J32 VTB Fan 1 FAN2_STALL_IN 2 Ground
    3 VTB_FAN_OUT (Fan 2 control)
    4 +24V_LEFTSIDE
    J33 Fuser Interface 1 EXIT_SENSOR_IN
    2 FU SER _CAM_1_IN
    3 Ground
    4 OILER_ENC_A_IN
    5 OILER_ENC_B_IN
    6 HR_THERM_IN (hot roll thermistor)
    7 BR_THERM_IN (backup roll thermistor)
    8 Ground
    9 +5V_SWITCHED
    10 ZERO_XING_IN
    11 HR_HEAT_ON_OUT (hot roll control)
    12 BR_THERM_ON_OUT (backup roll control)
    J34 Magenta/Cyan BLDC Motors 1 M_ON_OUT
    2C_ON_OUT
    3 +5V dc (Through fuse F8)
    4 +5V dc (Through fuse F8)
    5 M_DIR_OUT
    6C_DIR_OUT
    7 +24V_M_AND_C (Through fuse F5)
    8 +24V_M_AND_C (Through fuse F5)
    9 Ground
    10 Ground
    11 M_CLK_OUT
    12 C_CLK_OUT
    13 M_HALL_IN
    14 C_HALL_IN
    15 N/C
    16 N/C
    17 N/C
    18 N/C
    See “System board - non-network” on page 5-6  or “System board - network” on page 5-7 .
    Connector Pin no. Signal 
    						
    							
    Connector locations5-17
      5060-4xx
    J35 Low Voltage Power Supply 1 +3.3 V dc 2 +3.3 V dc
    3 +5 V dc
    4 +5 V dc
    5 +24V dc
    6 +24V dc
    7 +24V dc
    8 +3.3 V dc Sense
    9 Ground
    10 Ground
    11 Ground
    12 Ground
    13 Ground
    14 Ground
    15 Ground
    16 Ground
    J37 Bottom Options Connector
    Waste Toner Full
    Media Size 1 Printer TXD
    2 Ground
    3 Ground
    4 Printer RXD
    5 +24V_OPTIONS (Through fuse F11)
    6 Ground
    7 +5V_OPTIONS (Through fuse F9)
    8 Staging Encoder
    9 ITU_CLNR_FULL
    10 N/C
    11 Ground
    12 WASTE_BTL_PRES
    13 TR AY_SIZE_3
    14 Ground
    15 TR AY_SIZE_2
    16 TR AY_SIZE_1
    17 Ground
    18  +3.3 V dc (Through fuse F13)
    19 MEM_DATA (I²C Data to Media Size Card)
    20 MEM_CLK (I²C Clock to Media Size Card)
    See 
    “System board - non-network” on page 5-6  or “System board - network” on page 5-7 .
    Connector Pin no. Signal 
    						
    							
    5-18Service Manual
    5060-4
    xx   
    Autoconnect—top
    JT25 - Diagnostic port 1 Ground
    2 Printer RXD
    3 Printer TXD
    4 +5V dc (Through fuse F8)
    Connector Pin no Color Signal
    CN1 Autoconnect—top 1 White +24 V dc 2 Black Ground
    3 Yellow Printer RXD
    4 Black Ground
    5N/A NC
    6 Red +5 V dc
    7 Black Ground
    8 Blue Printer TXD
    See “System board - non-network” on page 5-6  or “System board - network” on page 5-7 .
    Connector Pin no. Signal 
    						
    All Lexmark manuals Comments (0)