    Repair information4-75
      5060-4xx
    Installation notes
    
    To identify the color coded cable bands to the connectors, see  “Transfer high voltage power supply 
    (HVPS)” on page 5-20 . 
    When installing the transfer HVPS board, route the cable to the HVPS input connector at CN1 (C) over the 
    cable to the yellow transfer contact (D), under the cable to the magenta transfer contact (E), and attached 
    to the cable tie (F). This makes sure the toroid (G) does not come into contact with the motor when the card 
    is in place. 
    						
    							
    4-76Service Manual
    5060-4
    xx   
    Transfer plate assembly
    Go to “Transfer plate assembly” on page 7-12  for part number.
    1.Remove the S2/narrow media/transparency/multipurpose feeder cable. See  “S2/narrow 
    media/transparency/multipurpose feeder cable” on page 4-70 .
    2.Remove the transfer plate. Lifting and rotating the right edge of the plate up to a 45° angle releases the 
    transfer plate. Remove the grounding strap (A) attached to the bottom of the transfer plate. 
    3.Remove the transfer plate assembly.
    A 
    						
    							
    Repair information4-77
      5060-4xx
    Vacuum transport belt (VTB)
    Go to “Vacuum transport belt assembly” on page 7-11  for part number.
    1.Remove the transfer plate assembly. See “Transfer plate assembly” on page 4-76 .
    2.Remove the fuser bottom duct. See “Fuser bottom duct” on page 4-36 .
    3.Remove the two front screws (A).
    4.Loosen belt (B) on redrive assembly and remove from redrive gear.
    5.Remove belt from gear on vacuum belt transfer unit. 
    						
    							
    4-78Service Manual
    5060-4
    xx   
    6.Rotate release lever on gear until the gear can be removed.
    7.Remove screw from ground wire.
    8.Remove vacuum belt transfer belt unit far enough to release ground wire from restraint clips and remove 
    completly. 
    						
    							
    Repair information4-79
      5060-4xx
    Vacuum transport belt (VTB) fan
    Go to “VTB fan, 60 mm” on page 7-35  for part number.
    1.Disconnect VTB fan from the system board.
    2.Remove VTB fan with a flatblade screwdriver.
    Waste container door
    Go to “Waste container door” on page 7-5  for part number.
    1.Open the waste container door.
    2.Flex the door and remove it from the hinges (A).
    A 
    						
    							
    4-80Service Manual
    5060-4
    xx   
    Waste container latch
    Go to “Waste container latch” on page 7-26  for part number.
    1.Remove the paper size sensing assembly. See  “Paper size sensing assembly” on page 4-55 .
    2.Use a flatblade screwdriver to release the waste container latch from the paper size sensing assembly.
    Web oiler fuser kit installation
    1.Enter Diagnostic mode. See “Entering Diagnostics mode” on page 3-13 .
    2.Select PRINTER SETUP .
    3.Select Configuration ID .
    4.Increase the last two digits each by four.
    The left digit blinks, indicating it is the first digit to be changed. Press  Select to accept the current value and 
    skip to the next digit. Change the two digits on the right to increase each of their values by four. For 
    example, in this case, change 1234 56 to 12349A. To change the value of a digit, press  Menu until the 
    desired value is displayed and press  Select. When the last (rightmost digit) is changed and  Select is 
    pressed, the new value is set. The printer automatically begins POR.
    5.Turn the printer off.
    6.Open the fuser access cover.
    Configuration ID
    =123456* 
    						
    							
    Repair information4-81
      5060-4xx
    7.Unlatch the two fuser latches (A).
    8.Remove the fuser assembly.
    9.Open the front cover.
    10.Remove the yellow print cartridge.
    11.Remove the front right light shield screws (B) and (C) and remove the light shield.
    A
    C(324)B(323) 
    						
    							
    4-82Service Manual
    5060-4
    xx   
    12.Carefully remove the paper path access door cover right mounting screw (D).
    13.Tape front jam access door (E) if tape is available, to help hold the door in place.
    14.Remove the front right handle cover assembly screws (F) and remove the assembly.
    15.Open paper tray. 
    						
    							
    Repair information4-83
      5060-4xx
    16.Remove screw (G) from the top front support bracket. Swing bracket to the right.
    17.Use the alignment pins (H) on the web oiler fuser motor assembly to position the assembly in holes (J) and 
    install the assembly. 
    						
    							
    4-84Service Manual
    5060-4
    xx   
    18.Secure the web oiler motor assembly with screws (K).
    19.Install the web oiler card using screws (L).
    K
    L 
    						
    All Lexmark manuals Comments (0)