DESCRIPTION AND OPERATION 4.90FREELANDER 02MY Cooling Fan Control Unit – 01MY Fusible link 5 of the engine compartment fuse box (C0573) provides a constant battery feed to the cooling fan control unit (C0701) on an NW wire. Fuse 4 of the engine compartment fuse box (C0575) provides a feed to the cooling fan control unit (C0701) on an NK wire when the main relay in energised (see above). The cooling fan control unit (C0701) is earthed on a B wire. To control cooling fan and condenser fan speed, the...
Page 122
DESCRIPTION AND OPERATION FREELANDER 02MY 4.91 Cooling Fan Control Unit – 02MY Fusible link 5 of the engine compartment fuse box (C0573) provides a constant battery feed to the cooling fan control unit (C0208) on an NG wire. Fuse 4 of the engine compartment fuse box (C0575) provides a feed to the cooling fan control unit (C1680) on an NK wire when the main relay in energised. The cooling fan control unit (C0208) is earthed on a B wire. To control cooling fan and condenser fan speed, the ECM (C0913 on...
Page 123
DESCRIPTION AND OPERATION 4.92FREELANDER 02MY AIR CONDITIONING (A/C) – KV6 (NORTH AMERICA) DESCRIPTION General The air conditioning (A/C) system will only operate when the engine is running. The A/C system is switched on and off by pressing the switch mounted on the centre console. When the switch is pressed, an LED mounted within the switch illuminates to inform the driver the system is operational. For more information on LED operation, refer to the Interior Illumination section of this manual....
Page 124
DESCRIPTION AND OPERATION FREELANDER 02MY 4.93 OPERATION General Feed from the positive battery terminal (C0192) is supplied to fusible link 1, fusible link 5, and the main relay (C0632) on an R wire. All are located within the engine compartment fuse box. The earth path for the main relay coil (C0578) is controlled by the Engine Control Module (ECM) (C0604) on an NG wire. The energised main relay provides a feed to fuse 4, which is also located in the engine compartment fuse box. For more details on...
Page 125
DESCRIPTION AND OPERATION 4.94FREELANDER 02MY Instrument Pack The instrument pack (C0230) acts as a gateway, relaying CAN messages to and from different components throughout the vehicle as follows: Pressure Sensor The pressure sensor is located in the high pressure A/C line adjacent the compressor, and replaces the more traditional trinary pressure switch. The instrument pack (C0230) provides a 5 V reference voltage to the pressure sensor (C1257) on a UO wire. The pressure sensor (C1257) is provided...
Page 126
DESCRIPTION AND OPERATION FREELANDER 02MY 4.95 Cooling Fan Control Unit Fusible link 5 of the engine compartment fuse box (C0573) provides a constant battery feed to the cooling fan control unit (C0208) on an NG wire. Fuse 4 of the engine compartment fuse box (C0575) provides a feed to the cooling fan control unit (C1680) on an NK wire when the main relay in energised (see above). The cooling fan control unit (C0208) is earthed on a B wire. To control cooling fan and condenser fan speed, the ECM...
Page 127
DESCRIPTION AND OPERATION 4.96FREELANDER 02MY HEATER BLOWER DESCRIPTION General The heater is operated from three rotary controls located in the centre console. Two of the controls operate the temperature and air flow distribution. The third control operates the four speed blower motor. A resistor pack is mounted on the RH side of the heater unit. The resistor pack supplies reduced voltages to the blower motor for fan speed one, two, and three. Fan speed four drives the blower motor at full speed...
Page 128
DESCRIPTION AND OPERATION FREELANDER 02MY 4.97 Blower Speed 3 If blower speed 3 is selected, current flows across the blower motor switch (C0058) to the resistor pack (C0425) on an RG wire. The resistor pack (C0425) is connected to the blower motor (C0056) by a GK then G wire. As current has to flow through the smallest value resistor, the blower motor operates at an increased speed. Blower Speed 4 If blower speed 4 is selected, current flows across the blower motor switch (C0058) to the blower motor...
Page 129
DESCRIPTION AND OPERATION 4.98FREELANDER 02MY FUEL BURNING HEATER (FBH) DESCRIPTION General A Fuel Burning Heater (FBH) is used to compensate for the lower operating temperatures of Diesel engines by heating engine coolant before it enters the heater matrix. For a detailed description of FBH operation, refer to the Heating and Ventilation section of the Workshop manual. OPERATION General Feed from the positive battery terminal (C0192) is supplied to fusible link 1 of the engine compartment fuse...
Page 130
DESCRIPTION AND OPERATION FREELANDER 02MY 4.99 COOLING FANS DESCRIPTION K Series K Series vehicles are fitted with a single cooling fan, which is mounted on the rear face of the radiator. Operation of the single speed cooling fan is controlled by the Engine Control Module (ECM) via the cooling fan relay. NOTE: Vehicles fitted with Air Conditioning (A/C) are also fitted with a condenser fan and a cooling fan control unit. For more information, refer to the Air Conditioning (A/C) – K Series and KV6...