Chapter 3 Error Correction 3-18 3. 1. 3. 5 In Power Save Mode When “In Power Save Mode.” is displayed, KM-3650w is in the Power Save Mode to save the power consumption. (1) The Power Save Mode works automatically if you make no operation for the time specified in advance. The machine ceases controlling the temperature of Fuser Unit completely to save the power consumption. (Power Save Mode can save more power than Warm Sleep Mode.) (2) The Power Save Mode will be cancelled by the following 3 ways. • Making a print from the network • Inserting an original to the scanner • Pressing any key on the Operation Panel Note that it takes some minutes to recover from the Power Save Mode as the temperature of Fuser Unit must be raised again. (Print starts when the machine gets ready.) ! When the main switch is turned ON or during sleep mode recovery, the LCD takes 1 minute to display. Please do not turn OFF the main switch during this period. Reference Downloaded From ManualsPrinter.com Manuals

Chapter 3 Error Correction 3-19 3. 2 Service Call Errors You will note an error message “A significant error occurred. Call the service” on the operation panel if the machine has the fatal error. At this time one of the following sub messages is displayed also. Counter Error Cutter Error Developer Motor Error FPGA Error Fuser Low temp Fuser Motor Error Fuser Over temp HV Charger Error License Key Error Main Motor Error PLEASE CALL YOUR TRAINED SERVICE PERSONNEL TO RESOLVE THESE ERRORS. If any of the above errors is displayed: 1. Turn off the machine, wait approximately 30 seconds, and then turn on the machine again. 2. If the same error message is displayed, turn off the machine, and then unplug the machine from the wall outlet. Call your service personnel. Downloaded From ManualsPrinter.com Manuals

Chapter 4 Maintenance 4-1 Chapter 4 Maintenance Page 4. 1 Cleaning of Each Part 4- 2 4. 1. 1 Scanner Unit 4- 2 4. 1. 2 Print Engine 4- 4 4. 1. 3 Operation Panel 4- 6 Downloaded From ManualsPrinter.com Manuals

Chapter 4 Maintenance 4-2 4. 1 Cleaning of Each Part 4. 1. 1 Scanner Unit Clean each Scan Glass, Feeding Rollers and Guide Plates once per a week, as the scan/copy image may become defective if these parts are dirty. 1. Confirm that the machine is turned off. 2. Open the Scanner Unit pulling up the Levers (1). 3. Wipe each Scan Glass (2) and Feeding Rollers (3) with a soft cloth. Use the neutral detergent mixed with 50% of water as the cleaner. NOTE Do not use organic solvent, glass cleaner and anti-static spray for the cleaning. 1 23 3 Downloaded From ManualsPrinter.com Manuals

Chapter 4 Maintenance 4-3 4. Wipe both the Upper Guide Plate (4) and the Lower Guide Plate (5) with a soft dry cloth. 5. Move the Scanner Unit a little to the rear side to unlock, and then close it. 4 5 Downloaded From ManualsPrinter.com Manuals

Chapter 4 Maintenance 4-4 4. 1. 2 Print Engine Clean each Guide Film and Guide Plate once per a week, as the toner or paper dust may accumulates on such part which may result in a defective print image. 1. Confirm that the machine is turned off. 2. Open the Engine Unit pulling up the Engine Unit Open Levers (1). 3. Wipe each Guide Film (2) and Guide Plate (3) with a soft dry cloth to remove the toner or paper dust. 2 3 1 Downloaded From ManualsPrinter.com Manuals

Chapter 4 Maintenance 4-5 4. Close the Engine Unit. NOTE (1) Photoconductive Drum (large green cylinder) right above the Guide Film. You need to replace the Drum if damaged, as it is a very important part in creating the print image. Be careful about the following matters. a.) Do not touch the drum. If you put your fingermark or oil on the Drum, it will cause for the defective image. b.) Take off such metal accessories as watch or ring. You will have to replace the Drum if you damage the Drum scratching with such accessories. c.) Do not leave the Upper Unit open for more than 10 minutes as the Drum is very sensitive to light. (Direct sunlight is very harmful.) (2) Do not use water, organic solvent and alcohol for the cleaning. Photoconductive Drum Downloaded From ManualsPrinter.com Manuals

Chapter 4 Maintenance 4-6 4. 1. 3 Operation Panel Clean the Operation Panel once per a week. 1. Confirm that the machine is turned off. 2. Wipe the Operation Panel with a dry cloth. NOTE Do not use water, alcohol, organic solvent and glass cleaner for the cleaning. Downloaded From ManualsPrinter.com Manuals

For best results and machine performance, we re commend that you use only our original supplies for your products. Downloaded From ManualsPrinter.com Manuals