Page 41
INTER-TEL PRACTICES INSTALLATION 824 INSTALLATION & MAINTENANCE Issue 1, June 1984 FIGURE 3-5. STATION CABLE TERMINATIONS ON THE KTI BLOCK Terminal Number 26 WH - BL Tl TIP CKT 1 1.1 2.5 1 BL - WH Rl RING CKT 1 27 WH - OR +1 +3aV CKT 1 2 OR - WH Gl GROUND CKT 1 28 3 29 4 30 WH - GN T2 GN - WH R2 WH - BR +2 BR - hH G2 TIP CKT 2 1.2 2.6 RING CKT 2 +3aV CKT 2 GROUND CKT 2 WH - SL T3 TIP CKT 3 1.3 2.7 SL - WH R3 RING CKT 3 R - BL +3 +3aV CKT3 BL - R G3 GROUND CKT 3 3: 6...
Page 42
INTER-TEL PRACTICES INSTAJAATION 824 INSTALLATION & MAINTEiNANCE Issue 1, June 1984 1 c. CONNECTING DOOR-MATES AND EXTERHAL EQUIPMEWT TO THE MDF 4.06 The MDF PCB has a Miscellaneous connector which provides the interface from the KSU to the MDF for Door-Mates, the FAX line monitor, external paging equipment, three remote contacts, the Master-Tel connection, and the KSU frame ground. Refer to SYSTEM SPECIFICATIONS for descriptions of these features. 4.07 To connect the equipment to the...
Page 43
INTER-TEL PRACTICES INSTALLATION 824 INSTALLATION S MAINTENANCE Issue 1, June 1984 ;i . . FIGURE 3-6. MISCELLANEOUS TERMINATIONS ON THE MISC BLOCK MDF PART OF MISC --- --- --- we- --- a-- --- --- \iPU RTN 1 PAM ZONE 9 1 -J --- --- --- 40 SK/SL 15 SL/BU ‘ll Y/ F11 --- -a- --- --- -a- --- --- --- --- --- --- --- --- --- --- MISC CONNECTOR ON THE MOF PC0 ---- ---- -a-- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- +&i-j MASTERTEL j 45 20...
Page 44
INTER-TEL PRACTICES INSTALLATION 824 INSTALLATION & MAINTENANCE Issue 1, June 1984 D. LOOP RESISTANCE TESTS 4.08 Keysets must not exceed the loop limit of 800 feet or 40 ohms, using 24 AWG wire. The loop limit applies to any station, even with a Power Failure Transfer keyset. Door-Mate units must not exceed loop limits of 400 feet or 20 ohms. 4.09 Excessive and/or high resistance connections reduce the cable lengths. Using larger gauge (smaller AWG number) or multiple 24 AWG wires for the...
Page 45
INTER-TEL PRACTICES INSTALLATION 824 INSTALLATION & MAINTENANCE Issue 1, June 1984 KTI Bridging Clips . 4.10 After testing the loop resistances and correcting cabling problems, complete the terminations on the MDF by placing bridg- ing clips on the KTI blocks and MISC block. ********************************************** * CAUTION * * Hot pre-wires are not permitted. Do not * * bridge cables with unequipped stations. * * Failure to comply may cause data errors, * * which in turn will cause...
Page 46
INTER-TEL PRACTICES INSTALLATION 824 INSTALL.ATION & IlAINTENANCE Issue 1, June 1984 5. KEY SERVICE UNIT (KSU) INSTALLATION 5.01 This section includes the following; A. Unpack the Equipment B. Power Supply Installation C. Printed Circuit Board (PCB) Installation D. Complete the KSU Installation A. UNPACK THE EQUIPMENT (1) Unpack the equipment, check it against the packing slip, and inspect it for damage. If equipment is missing or damaged, contact Inter-Tels Order Processing Department...
Page 47
INTER-TEL PRACTICES INSTALLATION 824 INSTALLATION & MAINTENANCE Issue 1, June 1984 Installation (1) Remove the KSUs cover by removing two screws at the top, two screws at the bottom, and lifting it off. (2) If the power supply is shipped installed in the cabinet, make sure all connections are correct. 3-7 and 3-8 on the following pages. Refer to Figures OR, (3) If a. b. C. d. e. the power supply is not installed: Remove the two screws at the bottom of the cabinet. From the front, slide...
Page 48
INTER-TEL PRACTICES INSTALLATION 824 INSTALLATION & MAINTENANCE Issue 1, June 1984 FIGURE 3-7. SYSTEM POWER SUPPLY d ‘SKTI 2 478KTI 3 k&SC bOOR /; BATTERY BACKUP SELECT SWITCH-.- .-_ ._._ A 3 (-) EXTERNAL BATTERY CONNECTION (+) EXTERNAL BATTERY POWER FAILURE ALARM CONNECTION CONTACTS Page 3-17
Page 49
INTER-TEL PRACTICES 824 INSTALLATION & MAINTENANCE INSTALLATION Issue 1, June 1984 ‘: .I FIGURE 3-8. POWER SUPPLY CONNECTIONS ON TBE BACKPLANE A +24V GROUND n 3 +5v +5 V GROUND +24V Page 3-18
Page 50
INTER-TEL PRACTICES INSTALLATION 824 INSTALLATION 6r MAINTENANCE Issue 1, June 1984 i Power Supply Electrical Test (1) (2) (3) (4) (5) (6) t (7) Make sure the power supply 6A 250V fuse is in good work- ing order. The power supply ON/OFF switch must be in the OFF posi- tion. Also make sure there are no PCBs installed in the cardfile at this time. Plug the power cord into the dedicated 105-125VAC, 60Hz outlet. Set the ON/OFF switch to the ON position. Locate the test points on the...