Page 31
INTER-TEL PRACTICES SYSTEM SPECIFICATIONS 824 INSTALLATION b MAINTENANCE Issue 1, June 1984 FIGURE 2-6. KEY SERVICE UNIT (KSU) . . . A I LINE SEPARATION SWITCHES A 5 DOOR-MATE VOLUME CONTROL n 2 RS232C INTERFACE n 6 BATTERY BACK-UP SELECT SWITCH A 3 M OH PHONE JACK L+ A 7 AC LINE FUSE EXTERNAL PAGE VOLUME A 6 AC POWER SWITCH CONTROL Page 2-17
Page 32
INTER-TEL PRACTICES INSTALLATION 824 INSTALLATION & MAINTENANCE Issue 1, June 1984 I INSTALLATION CONTENTS PAGE 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 1. INTRODUCTION INTRODUCTION ............................................ 3-l SITE PLANNING ........................................... 3-l CABLING ................................................. 3-3 ASSEMBLING THE MAIN DISTRIBUTION FRAME (MDF) BACKBOARD . . 3-5 KEY SERVICE UNIT (KSU) INSTALLATION ..................... 3-15 KEYSET...
Page 33
INTER-TEL PRACTICES INSTALLATION 824 INSTALLATION & MAINTENANCE Issue 1, June 1984 A. KEY SERVICE UNIT (KSU) SITE PLANNING 2.02 Prior to installing the 824 equipment, select a centralized location for the KSU and Main Distribution Frame (MDF) which will minimize cable run lengths from each station and provide the proper environmental conditions. A. Availability to 105-125VAC, 60Hz single-phase commercial power. NOTE : This must be a dedicated, separately fused AC in- put for proper...
Page 34
INTER-TEL PRACTICES INSTALLATION 824 IBSTALLATION & MAINTENANCE Issue 1, June 1984 B. TOOLS AND SUPPLIES REQUIRED H. Supply standard telephone hand tools. 3. CABLING A digital voltmeter is required to check the power sup- PlY, and ensure correct wiring of the modular jack assem- blies. Accuracy of the meter must be +0.258 or better. - An AMP MI-1 Butterfly connector machine or equivalent is used to assemble the SO-pin amphenol connectors for the MDF PCB. Supply 25-pair cable and SO-pin...
Page 35
INTER-TEL PRACTICES INSTALLATION 824 INSTALLATION & MAINTENANCE Issue 1, June 1984 * A. RUNNING CABLE 3.03 Run two-pair cable to each station location shown on the floor plan. Both ends of every cable must be labeled with the circuit number. Run one-pair cable to each Door-Mate location. Follow A. B. C. D. E. F. these guidelines: Avoid cable runs parallel to fluorescent light fixtures or AC lines not in conduit. If they are unavoidable, run the cable perpendicular to the obstacles. Do...
Page 36
INTER-TEL PRACTICES INSTALLATION 824 INSTALLATION h MAINTENANCE Issue 1, June 1984 4. ASSEMBLING THE MAIN DISTRIBUTION FRAME (MDF) BACKBOARD 4-01 The MDF is the point at which the KSU, the stations, and the C.O. lines are connected to one another. It is. extremely important that this be done accurately. 4.02 The MDF backboard should be constructed to present a neat appearance, readily facilitate changes, have cables of proper length, and be correctly labeled. A 3X4-foot 3/4-inch plywood...
Page 37
INTER-TEL PRACTICES INSTALLATION 824 INSTALLATION & MAINTENANCE Issue 1. June 1984 A. CONNECTING C-0. LINES TO THE MDF .: 4.03 Central Office (C.O.) lines are typically terminated on an RJ-21X or RJ-14C connector. Then you terminate the lines on the MDF. Refer to Figure 3-3 on the next page. (1) One connection block on the MDF is dedicated for all C.O. line connections. Terminate a 25-pair cable from the right side of this block to the RJ-21X or RJ-14C. Label both ends. (2) Make an MDF PCB...
Page 38
INTER-TEL PRACTICES INSTALLATION 824 INSTALLATION & MAINTENANCE Issue 1, June 1984 FIGURE 3-3. C-0. LIME TERMINATIONS ON TEIE MDF WH/BL BL/WH WH/OR OR/WH WH/GN GN/WH WH/BR BR/WH WH/SL SL/WH R/BL BL/R R/OR OR/R R/GN GN/R R/BR B R/R R/SL SL /R TI ---- RI ---- T2 ---- R2 ---- T3 a--- R3 ---- T4 ---- R4 ---- T5 ---- R5 ---- T6 ---- R6 ---- T7 ---- R7 ---- TB ---- RB ---- a--- ---- ---a GN/V V/BR BR/V V/SL 6 TO CO. CONNECTOR ON MDF PCB d TO TELCO...
Page 39
INTER-TEL PRACTICES INSTALLATION 824 INSTALLATION h MAINTENANCE Issue 1, June 1984 B. CONNEXTING STATION CABLES TO THE MDF 4.05 After station cables are run, they are connected to the MDF as described below. Refer to Figure 3-4 and Figure 3-5 on the following pages. (1) (2) (3) Ensure both ends of the cable are labeled with the cir- cuit number. Terminate each station cable on the right side of the designated KTI block. NOTE : Each KTI block supports up to 12 stations. Make an MDF PCB...
Page 40
INTER-TEL PRACTICES INSTALLATION 824 INSTALLATION & MAINTENANCE Issue 1, June 1984 FIGURE 3-4. STATION CABLE TERMINATIONS PART OF MOF KTI BOARD - -iIs 1-I =I.1 - - -- -- -- - --- ---- ---- 1 OR/WH ON0 7 OR/WI-l ON0 TO KEYSET Page 3-9