    							HRDP DVR User Guide 
     
    ________________________________________________________________________\
    ______________________ 
    Document 800 -06801   Rev D  21 
    02/11    
    Quick Start Instructions 
    1.
      Turn on the DVR. See the  Turning on the DVR  section for more details.   
    2.   Log in --  Use the number buttons to enter the password when prompted 
    –  The  default  password is  –  Press ENTER. 
    3.   Complete System Configuration to set up the date, time and system ID. 
    See the System Configuration  section for more details. 
    4.   Complete Disk Configuration to set overwrite options and enable SMART 
    Check. See the Disk Configuration section for more details. 
    5.   Complete User Configuration to change the Admin password and add 
    additional users. See the System >User Configuration section for more 
    details.  
    6.   Complete Camera Configuration for all attached cameras. See the 
    Camera Configuration  section for more detail. 
    7.   Complete PTZ Configuration for any attached Pan / Tilt / Zoom cameras. 
    See the PTZ Configuration  section for more details. 
    8.   Create a recording schedule. See the Record  section for more details. 
    9.   Complete Sensor Configuration to enable any external devices 
    connected to sensor inputs  or relay outputs. See the Record > 
    Motion/Event Configuration  section for more details. 
    10.  Complete Motion/Event Configuration to trigger recording on an event: 
    motion,  sensor, video loss. See the Motion/Event Configuration  section 
    for more details. 
    11.  The DVR is now configured to record, search and playback video. See 
    the  Operation  section in this manual for more information on using the 
    DVR.  
     
    Logging In for the First Time  
    The default administrative log in information:  
     
    ID:  admin 
    Password:    
          
    						
    							Installation 
     
    ________________________________________________________________________\
    ______________________ 
    22  
       
    Installation
     
    Front  Panel  Controls  
     
     
       
    USB Port LED Lights 
    •  Power  
    •  HDD  
    •  Record  
    •  Network  
    •  HDD Temp.  
    DVD Drive Numeric Keypad Arrow Buttons 
    Live Display 
    Setup Menu 
    Lock (logout) 
    Search Mode 
    Backup Menu 
    Rotate  
    Instant  Record  
    						
    							HRDP DVR User Guide 
     
    ________________________________________________________________________\
    ______________________ 
    Document 800 -06801   Rev D  23 
    02/11    
    Rear Panel Connectors
     
    The rear panel of the DVR  contains virtually all of the connectors you will be 
    using.  The diagram below shows the location and description of each 
    connector. 
     
    16 Channel 
     
       
    Primary and Spot Monitor Outputs 
    Power Input 
    RS-232 Input  
    VGA Output 
    USB Port 
    Video In Ports  
    Video Out Ports  
    Relay Output 
    Sensor Input 
    Audio Input  
    PTZ Connection  
    Audio Output  
    NTSC/PAL switch 
    Network Port  
    						
    							Installation 
     
    ________________________________________________________________________\
    ______________________ 
    24  
       
    8 Channel  
     
    4 Channel 
     
     
       
    RS-232 Input 
    Video Out Ports 
    Video In Ports 
    Relay Outputs 
    Sensor Inputs 
    Audio Input Cable Connections PTZ Connection 
    Primary and Spot 
    Monitor Outputs Network Port 
    USB Port 
    Power Input 
    Audio Output  NTSC/PAL switch 
    Primary and Spot Monitor Outputs 
    Network Port 
    RS-232 Input 
    VGA Output 
    USB Port 
    Relay Output 
    Sensor Input Audio Input Cable Connection 
    PTZ Connection Video Out Ports 
    Video In Ports 
    Power Input 
    Audio Output  
    NTSC/PAL switch  
    						
    							HRDP DVR User Guide 
     
    ________________________________________________________________________\
    ______________________ 
    Document 800 -06801   Rev D  25 
    02/11    
    Remote Control
     
     
       
    ROTATE ALARM OSDPTZ
    EXIT
    REPL AY
    ENTER
    ZOOMFOCUSIRIS
    PTZ
    PRESE T
    +10
    LIVESEARCHBACKU
    P
    SETU
    P
    0
    789
    456
    1
    ID23
    REC
    S
    P
    -30+30
    Record Toggle
     ID Select*  
     Arrow / Panorama 
      Arrow 
    Rewind 
    Pause 
      Arrow  
    Display Options  
    Play 
    Fast Forward  
    Log Off (Lock)  
    PTZ Controls  
    *The ID Select button  allows 
    you to use one remote control 
    for several DVRs.   
    						
    							Installation 
     
    ________________________________________________________________________\
    ______________________ 
    26  
       
    Connection Guide
     
     
    Connecting the Monitor 
    There are three available monitor outputs on the  DVR.  
    •  Composite Monitor output for CCTV moni tor – BNC (Marked MAIN)  
    •  Spot monitor output for CCTV monitor  -  BNC (Marked SPOT) 
    •  VGA output for VGA monitor –  Mini-Sub D15  
     
    Video Input s and Loop ing Outputs   
    The HRDP DVR comes with 4/8/16 BNC video inputs on the rear of its 
    chassis. Each video input has a corresponding looping BNC output for 
    passing the video signal to another monitoring/recording device. 
     
    Connecting to a Network  
    Use the RJ45 jack on the rear of the DVR when connecting to a network.  
     
     
     
    Connecting Audio  
    To record audio on the DVR connect the audio source to the connections on 
    the audio ports on the back of the DVR. 
    To listen to live or recorded audio connect the Audio Out Port to an amplified 
    speaker system. 
    Note   The DVR audio output is a line level source which requires an 
    amplified  speaker system. The audio input can be from an amplified 
    source or line level microphone.  
        
    						
    							HRDP DVR User Guide 
     
    ________________________________________________________________________\
    ______________________ 
    Document 800 -06801   Rev D  27 
    02/11    
    Connect
    ing a PTZ Camera  
    The RS485 connector can be used to control Pan / Tilt / Zoom (PTZ) cameras. 
    See the PTZ camera manufacturer’s manual for configuring the RS 485 
    connection.  
    N ote  Use the RS485 connector for external control systems such as a 
    control keyboard. Connect RX -/TX - and RX+/TX+ of the control system to the 
    TX -/RX - and TX+/RX+ (respectively) of the DVR.  
     
    Connecting to a Sensor Input  
    To make connections on the Alarm Connector Strip : Press and hold the 
    button and insert the wire into the hole below the button.  To disconnect the 
    wire press and hold the button above the wire and pull it out.  
    Alarm In  
    Use external devices to send a signal to the DVR when an  event occurs. 
    Mechanical or electrical switches can be wired to the Alarm In and Ground 
    (GND) connectors.  
    Note All connectors marked GND are common. Connect the ground side 
    of the alarm input and/or alarm output to the GND connector. 
     
    Connecting to a Relay  Output  
    To make connections on the Alarm Connector Strip : Press and hold the 
    button and insert the wire into the hole below the button.  To disconnect the 
    wire press and hold the button above the wire and pull it out.  
    Alarm Out  
    The DVR can activate externa l devices such as buzzers or lights. Connect the 
    external device to the Alarm Out and Ground (GND) connectors. See Sensor 
    Configuration in the manual for more details.  
     
    Installing the Rackmount Kit  
    Caution There must be a minimum 1U space between the DVR a nd any 
    other items in the rack. 
    1.  Attach  the rackmount brackets with the screws provided on each side of 
    the DVR. Do not remove the plastic edge guards.  
    2.   Mount the DVR in your rack.  
        
    						
    							Installation 
     
    ________________________________________________________________________\
    ______________________ 
    28  
       
    Turning on the DVR
     
    1.  Connect camera cables.  
    2.   Connect a network cable and a monitor cable. 
    3.   Connect the power cable to the DVR and wait until the main screen is 
    displayed on the connected monitor; this process will take approximately 
    two minutes.  
    Tip  See the Connection Guide section for more details  
     
    Using the Power Button 
    To start the DVR:   
    Press and hold the Setup/Power button on the front panel of the 
    DVR until the lights start to flash.  
     
    To shutdown the DVR:  
    Press and hold the Setup/Power button on the front panel of the DVR, log in 
    when prompted and select OK to shut down. 
    Not e  Only authorized users can shut down the DVR.  
     
    Setting the Remote Controller ID 
    When more than one HRDP  DVR is installed in the same location, you can 
    use one remote controller to control multiple DVRs  –  up to 20 DVRs . To 
    control mul tiple DVRs, you must change the remote controller ID to the DVR  
    ID of the DVR.  
     
    T o change the remote controller ID : 
    1.   On  the DVR, go to SYSTEM > SYSTEM CONFIGURATION.  
    2.   Enter the desired DVR ID number.  
    3.   On the remote controller, press and hold the ID button and  enter the 
    desired DVR ID number to operate the corresponding DVR. 
    Note  The DVR ID must be input as two numbers on the remote controller. 
    You must  input 00 for the system ID 0 and input 01 for 1.  
       
    						
    							HRDP DVR User Guide 
     
    ________________________________________________________________________\
    ______________________ 
    Document 800 -06801   Rev D  29 
    02/11    
    Setup
     
     
    Setup Menus  
     
     
    Use the setup menus to configure all of the DVR settings, schedule recording, 
    networking and shutdown.  
    Press the SETUP key on the front of the DVR or remote control to enter the 
    setup menus and log in. See the Logging In for the First Time section if 
    entering setup for the first time. Use  the   and   keys on the front of the 
    DVR or remote control to navigate individual menus, and use the   and   
    keys to select a new setup menu.  
        
    						
    							Setup 
     
    ________________________________________________________________________\
    ______________________ 
    30  
       
    Setup Wizard  
    The Setup Wizard allows you to define global recording settings for an easy 
    and custom recording schedule on the DVR.  
     
     
     
    Global Resolution  –  352 x240 / 704 ×  240 / 704 ×  480.  
    Record Mode  –  Continuous / Motion   
    Average Days to Record  –  [The estimated days of recording determined by 
    resolution, IPS (Images Per Second), Picture Quality, and available storage 
    size.]  
    IPS Per Channel  –  1-30 [Maximum varies with resolution.]  
    Picture Quality  –  Low / Normal / High / Highest  
     
        
    						
    All Honeywell manuals Comments (0)