5210l-L-1 30200-l 001 INST PAGE 0 RANGE 01 TEST #3MEMORY FAILURE LOCATION IS: 5FE0 DATA: WRITTEN FO READ Fl3. A pass count occurs after all ranges selected for testing are *completed and a retest requested. The count appears in decimal, runs from “00” to “99”, and repeats beginning at ” 00.” 4. Testing stops on the range for that pass only when a failure occurs. At the start of each pass, all ranges selected for testing are retested if the retest option was selected. 5. If a failure occurs on ranges CO...
Page 922
2. Enter a “0” if the Get Started File is tested and/or a “1” if the Expansion File is tested, followed by a (CR). If both files’ channel memories are tested, type “01”. If all files are selected, then a (CR) is not needed. The system responds: FOR RETEST TYPE 0; OTHERWISE TYPE 1 3. Now refer to step five of the System Memory Test procedures and continue (paragraph 96.1)..: Test Results9.9.2 All of the test results described may not appear since they depend on how the Channel Memory Test was set up. 1...
Page 923
TL-130200-1001Test Results9.192 After completion of the Paging Card Test, the system responds with the following : 1. With successful completion of the test the system responds: PAGING CARD PASSES TEST 2. Memory read-after-write error on instruction page 0, memory address 1100. The system responds: MEMORY WRITE FAILURE ON PAGING TEST PAGE 00 MEMORY FAILURE LOCATION IS: 1100 3. Paging failure in which page write went to Instruction Page 1 instead of instruction page 0 writing to range #l. The system...
Page 924
TL-130200-1001 2. If the channel memory was not initialized, the system responds: NETWORK FAILURE: CAN’T WRITE TO CHANNEL MEMORY TESTING STOPPED DUE TO THE ABOVE ERRORS 3. If control memories A or B were not initialized, the system responds: NETWORK FAILURE: CAN’T WRITE TO CONTROL TESTING STOPPED DUE TO THE ABOVE ERRORS 4.. If pad memory was not initialized, the system responds: NETWORK FAILURE: CAN’T WRITE TO PAD MEMORY TESTING STOPPED DUE TO ABOVE ERRORS 5. If channel, control, or pad memory was not...
Page 925
TL-130200-1001Fault Correction9.11.3 The following steps correct faults detected by the Network Test: 1. If the problem was found to be initializing or writing to channel, control, or pad memory, replace the Channel Memory 8085 card (FB-17218-A). Reinstall the original card if the problem continues after replacement. 2. Repeat the Network Test. 3. If the failure continues, check all cabinet cables for short circuits. If an open is found, replace the faulty cable and rerun the Network Test. NOTE: Steps 4,...
Page 926
TL-130200-1001 3. Verification of the FMS/disk communications link generates the following menu: I-------------------------------------------------,II/ DISK DEVICE TEST SELECTION MENUI I I) 0) REPEAT FMS TEST I II 1) TEST DEVICE #O (10 MBYTE FIXED)I I I2) TEST DEVICE #2 (800 KBYTE)II X) RETURN TO MAIN OFF LINE DIAGNOSTICS MENU i) ENTER SELECTION - > >II I !IIL---___------__-----------------------------------, - Selection of option “0” repeats the FMS test (on-line) - Selection of option “1”...
Page 927
TL-130200-100152103. Examples of FMS Test error messages include: . FMS COMMUNICATIONS ERROR PERFORMING FMS COMMUNICATION TEST ERROR DETECTED WHILE PERFORMING FMS COMMUNICATION TEST FMS TEST ENDED l FMS RAM ERROR PERFORMING FMS RAM TEST ERROR DETECTED WHILE PERFORMING FMS RAM TEST FMS TEST ENDED o FMS CONFIGURATION ERROR POLLING FMS FOR DISK CONFIGURATION ERROR DETECTED WHILE POLLING FMS FOR DISK CONFIGURATION FMS TEST ENDED l DISK TEST MENU WHEN FMS TEST FAILS DISK DEVICE TEST SELECTION MENU 0) REPEAT...
Page 928
The above steps generate the following messages as the system completes each operation:~-------------------------------------------------------------~! FIXED DISK DEVICE TEST IN PROGRESS....I1 PERFORMING DISK CONTROLLER DIAGNOSTICS I II - STILL PERFORMING DISK CONTROLLER DIAGNOSTICS:I DELETE TEST FILE j DETERMINING DISK FREE SPACE ICREATING TEST FILE / WRITING TO TEST FILE I STILLWRiTiNG TO TEST FILE I ISTILLWRITING TO TEST FILE II I STiLLWRiTiNG TO TEST FILE I ISTILLWRITING TO TEST FILE I I...
Page 929
TL-130200-1001r-------------------------------------------------~ ; FIXED DEVICE TEST SUCCESSFULLY COMPLETED fIIL-------------------------------------------------~The system displays the “DISK DEVICE TEST SELECTION MENU” on completion of this test. Test Device #29.12.4 Test Device #l (option 2) instructs the system to perform a read/write verification for the FMS and a floppy disk in the disk drive. The following prompts appear: INSERT A SPARE FLOPPY DISK IN DISK DRIVE NOTE: ANY DATA ON DISK WILL BE...
Page 930
. .TL-130200-1001 STILL FORMATTING FLOPPY DISK MOUNTING FLOPPY DISK DETERMINING DISK FREE SPACE CREATING TEST FILE WRITING TO TEST FILE STILL WRITING TO TEST FILE STILL WRITING TO TEST FILE CLOSING TEST FILE OPENING TEST FILE READING TEST FILE STILL READING TEST FILE STILL READING TEST FILE CLOSING TEST FILE DELETING TEST FILE FLOPPY DISK DEVICE TEST SUCCESSFULLY COMPLETED The system displays the “DISK DEVICE TEST SELECTION MENU” on completion of this test. Return to Main Menu9.12.5 Return to Main Menu...