Page 931
TL-130200-1001 Serial Device Controller Testing Procedures9.13.1 Use the following steps to conduct the Serial Device Controller Test: 1. Select Option “5” from the Menu of Test Options. The system responds: TYPE THE SDC PORT # YOU WISH TO TEST (0 OR 1) > > _.2. If Off-Line Diagnostics is not running on this port go to step 4. Otherwise, the system responds: TYPE ANY CHARACTER AND IT WILL BE ECHOED ON THE TERMINAL. TYPE CONTROL-K TO EXIT FROM THIS TEST 3. Any character key typed on the terminal keyboard...
Page 932
TL-130200-1001Tone Test9.14.1Use the following steps to conduct the Tone Test: Testing Procedures1. Select option “6” from the Menu of Test Options. The system responds: TONE CARD TEST PICK A CONVENIENT PHONE WITH WHICH TO LISTEN TO THE TONES. ENTER THE PHYSICAL LOCATION OF THIS PHONE. FILE NUMBER (A -- > D) > > . . 2. Type the correct file letter. The system responds: SLOT NUMBER (0 -- > 11) > > . . 3. Type the correct universal card slot number. The system responds: CIRCUIT NUMBER (0 -- > 7) > > ....
Page 933
Table 9.4 Tone Test Outputs r No.Terminal Output 4Busy Tone, Feature Confirmation Tone 5 6Reorder, Camp on Call-Waiting Tone Tick Tone Test Tone (1004 Hz, 1 Milliwatt) Ringback Tone IDial Tone 10DTMF “1” 11DTMF “2” 12DTMF “3”13 DTMF “4” 114IDTMF “5”I 15DTMF “6” 16DTMF “7” 20DTMF I’*” 21DTMF ‘I#”1 MF “KP” 23MF “1” 24MF “2” 125IMF “3”TL-130200-1001 52108187M-357
Page 934
TL-130200-1001Table 9.4 Tone Test Outputs (Continued) No.Terminal Output26M F “4” 27M F “5” 28MF “6” 29MF “7” 30MF “8” 31MF “9” 33MF “ST” 34MF “STP” 35MF “ST2P“ 36MF “ST3P” 37ICAS Tone (440 Hz) 38CAS Tone (480 Hz) 39Confirmation Tone Interrupted Dial Tone 41CAS Tone (620 Hz) 42Dial Tone at - 19 DBM 81875210
Page 935
TL-130200-1001 4. If Pad memory not initialized, the system responds: NETWORK FAILURE: CAN’T WRITE TO PAD MEMORY TESTING ENDED DUE TO ABOVE ERRORS 5. If, during test, channel, control, or pad memory cannot be read, the system responds: READ AFTER WRITE FAILURE MEMORY FAILURE LOCATION IS: XXXX TESTING ENDED DUE TO ABOVE ERRORS NOTE: See Network Test Results (Paragraph 8.11) to memory address of the card causing the problem. 6. The system will continue sending the same tone if a “G” is not entered to send...
Page 936
TL-130200-1001Attendant Interface9.15.1Use the following steps to conduct the Attendant Interface Card TestCard test: Testing Procedures1. Remove the Attendant Interface card (FB-17208-A) from the cabinet. Make sure that all four dip-toggle switches are in the off position. Reinstall the card into the cabinet. 2. Disconnect the cable for the Attendant/BLDU interface on the Attendant Interface card. 3. Strap together the transmit (TRAN) and receive (REC) leads on the Attendant Interface card...
Page 937
TL-130200-1001Fault Correction9.15.3 The following steps correct faults detected by the Attendant Interface Card Test: 1. Check the transmit and receive strapping if a “NO READY “signal error occurs. Also, remove the AMP connector from the ATT12 card slot and repeat the test. Replace the ATT12 card ifthe “NO READY“ signal error appears again and repeat the test. 2. If the ATT12 card itself failed the test, replace the card, and repeat the test.3. If the actual phone hardware was not available, check for...
Page 938
TL-130200-1001Table 9.5Line/Trunk Pair to Point Conversion Circuit No. CDF Points1 Line Circuit 01 Tip 1, Ring 11 Tip 2, Ring 2 ITip 3, Ring 31 Tip 4, Ring 4 ’ Tip 5, Ring 51 Line Circuit 1 Line Circuit 2 Line Circuit 3 Line Circuit 4 Line Circuit 6 ITip 7, Ring 7ILine Circuit 7Tip 8, Ring 8 Table 9.6Line/Trunk Pair to CDF Roint Conversion Circuit No.CDF PointsTrunk Circuit 0Tip 1, Ring 1 Trunk Circuit 1 I Tip 2, Ring 2 I Tip 3, Ring 3 Tip 4, Ring 4 Trunk Circuit 2 Trunk Circuit 3 Line/Trunk Test9.16.1...
Page 939
TL-130200-1001 4. Type the correct universal card slot number for the circuit. Thesystem responds: ClRCUlT NUMBER (0 -- > X) > > . . where X =3 for a trunk card and X =7 for a line card 5. Type the correct circuit number for the line or trunk circuit. The system responds: .-..IS SECOND CIRCUIT ON A LINE CARD OR ON A TRUNK CARD?TYPE “L” FOR LINES, TYPE,“T” FOR TRUNKS > > . . 6. Type the correct response for the second line or trunk circuit. Repeat steps two through five for this circuit.Test...
Page 940
To end the test and break the transmission path, type any character. 2. If channel memory does not initialize, the system responds: NETWORK FAILURE: CAN’T WRITE TO CHANNEL MEMORY TESTING ENDED DUE TO ABOVE ERRORS 3. If control memory A or B is not initialized, the system responds: NETWORK FAILURE: CAN’T WRITE TO CONTROL MEMORYTESTING ENDED DUE TO ABOVE ERRORS 4. If pad memory is not initialized, the system responds: NETWORK FAILURE: CAN’T WRITE TO PAD MEMORY TESTING ENDED DUE TO ABOVE ERRORS 5. During...