TL-130200-1001
Serial Device Controller
Testing Procedures9.13.1 Use the following steps to conduct the Serial Device
Controller Test:
1. Select Option “5” from the Menu of Test Options. The system
responds:
TYPE THE SDC PORT 
# YOU WISH TO TEST (0 OR 1) > >
_.2. If Off-Line Diagnostics is not running on this port go to step 4.
Otherwise, the system responds:
TYPE ANY CHARACTER AND IT WILL BE ECHOED ON
THE TERMINAL.
TYPE CONTROL-K TO EXIT FROM THIS TEST
3. Any character key typed on the terminal keyboard...

Page 932

TL-130200-1001Tone Test9.14.1Use the following steps to conduct the Tone Test:
Testing Procedures1. Select option “6” from the Menu of Test Options. The system
responds:
TONE CARD TEST
PICK A CONVENIENT PHONE WITH WHICH TO LISTEN
TO THE TONES. ENTER THE PHYSICAL LOCATION OF
THIS PHONE.
FILE NUMBER (A -- 
> D) > > . .
2. Type the correct file letter. The system responds:
SLOT NUMBER (0 -- 
> 11) > > . .
3. Type the correct universal card slot number. The system
responds:
CIRCUIT NUMBER (0 -- 
> 7) > > ....

Page 933

Table 9.4 Tone Test Outputs
r
No.Terminal Output
4Busy Tone,
Feature Confirmation Tone
5
6Reorder, Camp on
Call-Waiting Tone
Tick Tone
Test Tone (1004 Hz, 1
Milliwatt)
Ringback Tone
IDial Tone
10DTMF “1”
11DTMF “2”
12DTMF “3”13
DTMF “4”
114IDTMF “5”I
15DTMF “6”
16DTMF “7”
20DTMF I’*”
21DTMF 
‘I#”1
MF “KP”
23MF “1”
24MF “2”
125IMF “3”TL-130200-1001
52108187M-357 

Page 934

TL-130200-1001Table 9.4 Tone Test Outputs (Continued)
No.Terminal Output26M F “4”
27M F “5”
28MF “6”
29MF 
“7”
30MF “8”
31MF “9”
33MF “ST”
34MF 
“STP”
35MF “ST2P“
36MF “ST3P”
37ICAS Tone (440 Hz)
38CAS Tone (480 Hz)
39Confirmation Tone
Interrupted Dial Tone
41CAS Tone (620 Hz)
42Dial Tone at - 19 DBM
81875210 

Page 935

TL-130200-1001
4. If Pad memory not initialized, the system responds:
NETWORK FAILURE: CAN’T WRITE TO PAD MEMORY
TESTING ENDED DUE TO ABOVE ERRORS
5. If, during test, channel, control, or pad memory cannot be
read, the system responds:
READ AFTER WRITE FAILURE
MEMORY FAILURE LOCATION IS: XXXX
TESTING ENDED DUE TO ABOVE ERRORS
NOTE: See Network Test Results (Paragraph 8.11) to
memory address of the card causing the problem.
6. The system will continue sending the same tone if a “G” is not
entered to send...

Page 936

TL-130200-1001Attendant Interface9.15.1Use the following steps to conduct the Attendant Interface
Card TestCard test:
Testing Procedures1. Remove the Attendant Interface card (FB-17208-A) from the
cabinet. Make sure that all four dip-toggle switches are in the
off position. Reinstall the card into the cabinet.
2. Disconnect the cable for the 
Attendant/BLDU interface on the
Attendant Interface card.
3. Strap together the transmit (TRAN) and receive (REC) leads on
the Attendant Interface card...

Page 937

TL-130200-1001Fault Correction9.15.3 The following steps correct faults detected by the
Attendant Interface Card Test:
1. Check the transmit and receive strapping if a “NO READY 
“signal error occurs. Also, remove the AMP connector from the
ATT12 card slot and repeat the test. Replace the ATT12 card ifthe “NO READY“ signal error appears again and repeat the
test.
2. If the ATT12 card itself failed the test, replace the card, and
repeat the test.3. If the actual phone hardware was not available, check for...

Page 938

TL-130200-1001Table 9.5Line/Trunk Pair to Point Conversion
Circuit No.
CDF Points1  Line Circuit 01 Tip 1, Ring 11 Tip 2, Ring 2
ITip 3, Ring 31 Tip 4, Ring 4
’ Tip 5, Ring 51 Line Circuit 1
Line Circuit 2
Line Circuit 3
Line Circuit 4
Line Circuit 6
ITip 7, Ring 7ILine Circuit 7Tip 8, Ring 8
Table 9.6Line/Trunk Pair to CDF Roint Conversion
Circuit No.CDF PointsTrunk Circuit 0Tip 1, Ring 1
Trunk Circuit 1
I Tip 2, Ring 2
I Tip 3, Ring 3
Tip 4, Ring 4 Trunk Circuit 2
Trunk Circuit 3
Line/Trunk Test9.16.1...

Page 939

TL-130200-1001
4. Type the correct universal card slot number for the circuit. Thesystem responds:
ClRCUlT NUMBER (0 -- > X) > > . .
where X =3 for a trunk card
and X =7 for a line card
5. Type the correct circuit number for the line or trunk circuit. The
system responds:
.-..IS SECOND CIRCUIT ON A LINE CARD OR ON A TRUNK
CARD?TYPE “L” FOR LINES, 
TYPE,“T” FOR TRUNKS > > . .
6. Type the correct response for the second line or trunk circuit.
Repeat steps two through five for this circuit.Test...

Page 940

To end the test and break the transmission path, type any
character.
2. If channel memory does not initialize, the system responds:
NETWORK FAILURE: CAN’T WRITE TO CHANNEL MEMORY
TESTING ENDED DUE TO ABOVE ERRORS
3. If control memory A or B is not initialized, the system responds:
NETWORK FAILURE: CAN’T WRITE TO CONTROL MEMORYTESTING ENDED DUE TO ABOVE ERRORS
4. If pad memory is not initialized, the system responds:
NETWORK FAILURE: CAN’T WRITE TO PAD MEMORY
TESTING ENDED DUE TO ABOVE ERRORS
5. During...