Page 441

TL-130400-1001
CPG ERROR
MESSAGESTable 21.1CPG Error Messages (Continued)TITLE
DESCRIPTION OF MESSAGES
CP-53USE OF
DEVICE TYPE 
- PHYSICAL LOCATION THE PEC,
PHYSICAL LOCGROUP, SLOT AND CIRCUIT OF SOME DATA PORTS
CONFLICTSMUST BE DEFINED ON AN LD RECORD.
-rWITHDEVICE TYPE TERM MUST APPEAR ON AN LD
-..INSTRUMENTRECORD WITH INSTRUMENT TYPE ‘DFPA’ OR ‘APM’.
TYPE SPECIFIED DEVICE TYPE HOST MUST APPEAR ON AN LD
ON LDRECORD WITH
.-INSTRUMENT TYPE ‘DFPA’ OR ‘APM’.
DEVICE TYPE X25 MUST APPEAR ON AN LD RECORD
WITH...

Page 442

TL-130400-1001D-446
Table 21.1CPG Error Messages (Continued)DESCRIPTIONOF MESSAGES
PORTS DEFINED
ESS SPECIFIED MUST BE UNIQUE
ACROSS ALL CP RECORD. IN ADDITION,
THERE MUST BE NO CONFLICT BETWEEN THE
TWELVE NUMERIC DIGIT X.121 ADDRESSES FOR
SYNCHRONOUS DATA PORTS (DEVICE TYPES ‘X25’,
‘NIC’ AND ‘PX25’) AND THE FOURTEEN NUMERIC DIGIT
X.121 ADDRESSES FOR ASYNCHRONOUS DATA
PORTS (DEVICE TYPES ‘TERM’ AND‘HOST’)
EN ROTARY MUST HAVE THE
DCP SPECIFIED ON RECORD
NED ON RECORD CODE FR
SPECIFIED IN ADMP OR
(ADMPCK)...

Page 443

TL-130400-1001
CPG ERROR
MESSAGESTable 21.1CPG Error Messages (Continued)TITLE
DESCRIPTION OF MESSAGES
CR-02INVALIDAN INVALID SEQUENCE OF 
NPA/ABC CODES HAD
SEQUENCEBEEN SPECIFIED TO BE ENTERED.
Y-NO ENTRIES WERE MADE.
-..CHECK THE SEQUENCE CONTAINING THE
DESIGNATED COLUMN FOR A LOWER BOUND LESS
THAN OR EQUAL TO THE UPPER BOUND.
(TABGEN/GENDIG)
CR-03
IMPRObERTHE CPG HAS DETERMINED THAT THE FIRST
STARTING
NPA/ABC CODE LISTED ON THE CODE RESTRICTION
COLUMNRECORD IS NOT IN THE PROPER COLUMNS.
PROPER TABLE...

Page 444

TL-130400-1001Table 21.1CPG Error Messages (Continued)
CPG ERROR
MESSAGESTITLEDESCRIPTION OF MESSAGES
CT-03
. . .CT-04 
-FOR FUNCTIONFUNCTION CODE 
- HEXADECIMAL EQUIVALENT
CODE, TNAM,
BYTES
BYTES l-8IF THE FUNCTION CODE IS ‘TNAM’,
MAY NOT BETHEN THE HEXADECIMAL EQUIVALENT BYTES MAY
SPECIFIEDNOT BE SPECIFIED.
ELEMENT 2 IS
MEANINGLESS
SPECIFICATItjNCT-04ELEMENTSFUNCTION CODE 
- HEXADECIMAL EQUIVALENT
HAVEBYTES
INCOMPATIBLEIF THE FUNCTION CODE IS ‘TNAM’,
VALUESTHEN THE CUSTOMER DEFINED TERMINAL NAME
MUST...

Page 445

TL-130400-1001
CPG ERROR
MESSAGESTable 21.1CPG Error Messages (Continued)TITLE
DESCRIPTION OF MESSAGES
DA-51TRUNK GROUPTHE TRUNK GROUP SPECIFIED MUST HAVE A
NOT FOUND
CORRESPONDING 
Tl RECORD.
DA-52 
‘;IDUPLICATETHIS NUMBER MUST BE UNIQUE ACROSS ALL DA. .TRUNK GROUP RECORDS.
NUMBER
y-51DUPLICATEDISPLAYABLE CLASS OF SERVICE NUMBER MUST BE
DISPMYABLEUNIQUE ACROSS THE DC RECORDS.
CLASS OF
SERVICE DATA
DC-53TRUNKGROUP ATRUNKGROUPREFERENCEDONADCRECORD
NOT FOUNDWAS NEVER INPUT ON A 
Tl RECORD.
(ENDCHK)
DD-02...

Page 446

TL-130400-1001Table 21.1CPG Error Messages (Continued)CPG ERROR
MESSAGES
CDD-53
DD-54
DK-53I
DT-01
DT-01TITLE
TOLL ACCESS
-TRUNK
GROUP ACCESS
CONFLICT
CLASS OF
SERVICE NOT
DEFINED _
DUPLICATE
AGENT GROUP/
REPERTORY
DIAL KEY
NUMBER
VALUE OF
SECOND
ELEMENT TOO
SMALL
VALUE OF
SECOND
ELEMENT TOO
LARGEDESCRIPTION OF MESSAGES
IF TOLL ACCESS IS INDICATED (‘TA’) THEN AT LEAST
ONE TRUNK GROUP IN THE TRUNK GROUP ACCESS
FIELD ON RECORD DC SHOULD BE 
‘Y’.A DISPLAYABLE CLASS OF SERVICE REFERENCED ON
THE DD RECORD...

Page 447

TL-130400-1001Table 21.1CPG Error Messages (Continued)
ZPG ERROR
MESSAGESTITLEDESCRIPTION OF MESSAGES
DT-51CARD TYPE
DEFINED ON FR
INCOMPATIBLE
Y-WITH FCN OF
INCOMING
CARD
DT-51CARD TYPE
DEFINED ON FR
INCOMPATIBLE
WITH INCOMING
CARD TYPE
DT-51FUNCTION OFPHYSICAL LOCATION
CARD NOTTHE PEC, GROUP, SLOT AND CIRCUIT FUNCTION
ALLOWED FORSPECIFIED IS INVALID FOR THE CARD TYPE DEFINED
CARD TYPEON FR (FOR THIS PEC TYPE).
DEFINED ONA DTMF RECEIVER CIRCUIT MUST APPEAR ON A
FORM FRDTMF CARD.
THE PEC, GROUP, SLOT AND...

Page 448

 rTL-130400-1001ZPG ERROR
MESSAGES
Table 21.1CPG Error Messages (Continued)TITLE
DESCRIPTION OF MESSAGES
DT-57DUPLICATE
DTMF
RECEIVER
NUMBERTHE DTMF RECEIVER NUMBER MUST BE UNIQUE
ACROSS ALL DT RECORDS.
DT-58PEC NUMBER
THE PEC NUMBER SPECIFIED MUST BE MARKED
NOT EQUIPPEDEQUIPPED ON THE OE RECORD.
EC-01SECOND 
‘-NPA CODES MUST BE UNIQUE ON A PER TABLE
ELEMENT(ONE EC RECORD) BASIS
EQUALS FIRST
ELEMENT
(NPA CODES)
EC-03ELEMENTS
HAVE
INCOMPATIBLE
VALUES
EC-03ELEMENT 2 IS
MEANINGLESS
SPECIFICATION
EC-032ND...

Page 449

TL-130400-1001
CPG ERROR
MESSAGESTable 21.1CPG Error Messages (Continued)TITLE
DESCRIPTION OF MESSAGES
ED-52EXTENDEDEXTENDED DIAL CALL PICKUP TABLE
PICKUP GROUPEACH TABLE NUMBER SHOULD APPEAR ON AN LD
NOTRECORD IN THE EXTENDED DIAL CALL PICKUP TABLE
s-REFERENCEDFIELD.
-..ON LD FORM
(ENDCHK)
-FA-50DUPLICATE
FRL AUTHORIZATION CODE DUPLICATE
AUTHORIZATIO
FRL AUTHORIZATION CODES ARE NOT ALLOWED.
N CODE
NUMBER
FA-51FRLFRL AUTHORIZATION CODE
AUTHORIZATIOTHE NUMBER OF FRL AUTHORIZATION CODE DIGITS
N CODE OUT...

Page 450

TL-130400-1001ZPG ERROR
MESSAGES
Table 21.1CPG Error Messages (Continued)TITLE
DESCRIPTION OF MESSAGES
FR-01
. .
FR-OiVALUE OF
SECOND
ELEMENT TOO
LARGE
VALUE OF
CARD TYPE - PRIMARY, SECONDARY, TERTIARY
SECONDIDENTIFIERS CONSULT THE CARD TYPES VS.
ELEMENT TOOIDENTIFIERS,
SMALL
AND STATUS CHART TO DETERMINE APPROPRIATE
VALUES TO SPECIFY FOR EACH PARTICULAR CARD
TYPE.
FR-02ELEMENTS
CARD TYPE - PHYSICAL LOCATION
HAVEIF THE CARD TYPE IS DTRK, THEN THE GROUP FIELD
INCOMPATIBLEMUST BE ‘C’, SINCE 
Tl SPANS CAN...
Start reading GTE Omni Si Database Technical Practices Manual