Page 291
TL-130100-1001 ’Table 9.2 KEDU Response Code Identification FEATUREFUNCTIONHOUR/MINUTEDATA RESPONSE CODEDEFINITIONWake-UpEnter room numberFFFF or time in memory AValid response. Blank 1Nonexistent room. Enter timeTime entered via keysetAValid response. ‘Time entered via keyset2Invalid time. Time entered via keyset3Another time already in memory. Clear time from FFFFAValid response. memory FFFF5Room not on wake-up list. MessageMeteringEnter room numberCount in memoryAValid response. Blank 1Nonexistent...
Page 292
r O-28881875210 T‘L-I 30100-4 001 Table 9.2 KEDU Response Code identification (Continued) FEATUREFUNCTIONHOUR/MINUTE DATA RESPONSE CODE DEFlNlTlONTime Enter date and timeBlankBBBBMonth, day, hour, & minutes 1Nonexistent room. 5Room not restricted. ASystem accepts entry. Month, day, hour, &minutes 2Invalid entry. Message Waiting‘Enter room numberAAAA BBBB AMessage waiting activated.A Message waiting not activated. Alarm indicatorBBBB 1Nonexistent room. After a power failure FMessage metering and wake-up...
Page 293
TL-130100-1001STEPOPERATIONRESULT 34 5 6 5210Enter room number Depress ENTEFVXCUTE button. 8187(c) DATA field displays a three-digit code, as follows: The next function performed clears the KEDU.1. Left-most digit (field H) is either 0 for an unoccupied room or 1 for an occupied room. 2. Center digit (field I) is either 0 for an unavailable room or 1 for an available room. 3. Right-most digit (field J) gives information on the status of maid service for that room. 0= Status of the room is unknown (no...
Page 294
TL-130100-1001STEPOPERATIONRESULT Clearing Room Status Information 9Depress ROOM STAT button.(a) ROOM STAT LED on. (b) KEDU display fields out. (c) ROOM NUMBER LED on. (d) DATA LED on. 10Enter room number.Same as Step 5. 11Depress CLEAR button.(a) CLEAR LED on. (b) Display fields H through K off. (c) Response code display field off. 12Depress ENTER/XCUTE button.(a) Response code “A” is displayed in the response code field. (b) DATA field displays 000. 9.4.2Maid ServiceUsing a room telephone, the maid or...
Page 295
TL-130100-10011.Try a number of times at intervals before canceling the wake-up call with the number of times and the time intervals programmed in the data base. 2.Connect to the console or another station (data base programmable). STEPOPERATIONRESULT 1 2 NOTES: 1. 2. 3 4 5 6 5210 Enter Request for Wake-UpDepress WAKE-UP button.(a) WAKE-UP LED on. (b) KEDU display fields off. (c) ROOM NUMBER LED on. (d) HOUR-MINUTE LED on. Enter room number.(a) Room number displayed in ROOM NUMBER display field. (b) FFFF...
Page 296
TL-I 30100-l 001STEPOPERATIONRESULT(c) ROOM NUMBER LED on. (d) HOUR-MINUTE LED on. 7Enter room number.(a) Room number is displayed in the ROOM NUMBER field. (b) Data previously entered (wake-up time) shown on display field. (c) ROOM NUMBER LED on. (d) HOUR-MINUTE LED on. (e) Response code field displays “A”. 8Depress CLEAR button.HOUR-MINUTE field off. 9Depress ENTER/XCUTE button.(a) HOUR-MINUTE field displays FFFF. (b) The response code field displays “A”. (c) If printer is provided, see Table 9.1 for...
Page 297
TL-130100-1001STEPOPERATIONRESULT 4Depress ENTEFVXCUTE button. 5The next function performed clears the KEDU. Cancel Message Waiting 6Depress MESG WTG button. 7Enter room number. (If room number is three digits, enter a # after the third digit.) 8 9Depress CLEAR button.DATA and response code display fields off. Depress ENTEFVXCUTE button. 10The next function performed clears the KEDU. NOTE:When the room occupant responds to the message-waiting indication using the message center access code, the flashing...
Page 298
TL-130100-1001 STEPOPERATIONRESULT 1Depress MESG METER button. 2Enter room number. (Must be 4 digits. (a) Room number is displayed in the If 3 digits, enter a # after the thirdROOM NUMBER field. digit.)(b) DATA field displays the meter count (if any). 3The next function performed clears the KEDU. Entering New Count in Message Meter 4Depress MESG METER button. 5Enter room number. 6Depress ENTER/XCUTE button. 7 8Enter meter count (000 to 255).DATA field displays the meter count. Depress ENTER/XCUTE...
Page 299
TL-130100-1001 STEPOPERATIONRESULT11Enter room number.(a) Room number is displayed in the NUMBER field. (b) DATA field displays the meter count. (c) Response code field displays “A”. 12Depress CLEAR button.(a) DATA field off. (b) Response code “A” off. 13Depress ENTER/XCUTE button.(a) DATA field displays “A”. (b) The response code field displays “A”. (c) If printer is provided, see Table 9.1 for typical printer displays. 14The next function performed clears the KEDU. 9.4.6Audit Requests An audit may be...
Page 300
TL-130100-1001STEPOPERATIONRESULT 3Enter *** 1. 4(c) Printer will print the appropriate title and column heading followed by data. Abort Audit Request(a) ROOM NUMBER field displays ‘IEEE1 ‘I.(b) Response code field displays one of the following: 1. If the audit is stopped, “A” is displayed. 2. If the abort audit function is denied, “D” is displayed. 3. If the audit is not in progress, “F” is displayed. Message Meter Audit with Memory ClearEnter * * * 2.(a) ROOM NUMBER field displays “EEE2”.(b)...