Page 291

TL-130100-1001 ’Table 9.2 KEDU Response Code Identification
FEATUREFUNCTIONHOUR/MINUTEDATA
RESPONSE
CODEDEFINITIONWake-UpEnter room numberFFFF or time in memory
AValid response.
Blank
1Nonexistent room.
Enter timeTime entered via 
keysetAValid response.
‘Time entered via 
keyset2Invalid time.
Time entered via 
keyset3Another time already
in memory.
Clear time from
FFFFAValid response.
memory
FFFF5Room not on wake-up
list.
MessageMeteringEnter room numberCount in memoryAValid response.
Blank
1Nonexistent...

Page 292

 r
O-28881875210
T‘L-I 30100-4 001
Table 9.2 KEDU Response Code identification (Continued)
FEATUREFUNCTIONHOUR/MINUTE
DATA
RESPONSE
CODE
DEFlNlTlONTime
Enter date and timeBlankBBBBMonth, day,
hour, 
& minutes
1Nonexistent room.
5Room not restricted.
ASystem accepts entry.
Month, day,
hour, &minutes
2Invalid entry.
Message
Waiting‘Enter room numberAAAA
BBBB
AMessage waiting
activated.A
Message waiting not
activated.
Alarm
indicatorBBBB
1Nonexistent room.
After a power failure
FMessage metering and
wake-up...

Page 293

TL-130100-1001STEPOPERATIONRESULT
34
5
6
5210Enter room number
Depress 
ENTEFVXCUTE button.
8187(c) DATA field displays a three-digit code,
as follows:
The next function performed clears
the KEDU.1. Left-most digit (field H) is either 0
for an unoccupied room or 1
for an occupied room.
2. Center digit (field I) is either 0
for an unavailable room or
1 for an available room.
3. Right-most digit (field J) gives
information on the status of
maid service for that room.
0= Status of the room is unknown (no...

Page 294

TL-130100-1001STEPOPERATIONRESULT
Clearing Room Status Information
9Depress ROOM STAT button.(a) ROOM STAT LED on.
(b) KEDU display fields out.
(c) ROOM NUMBER LED on.
(d) DATA LED on.
10Enter room number.Same as Step 5.
11Depress CLEAR button.(a) CLEAR LED on.
(b) Display fields H through K off.
(c) Response code display field off.
12Depress ENTER/XCUTE button.(a) Response code “A” is displayed in the
response code field.
(b) DATA field displays 000.
9.4.2Maid ServiceUsing a room telephone, the maid or...

Page 295

TL-130100-10011.Try a number of times at intervals before canceling the
wake-up call with the number of times and the time
intervals programmed in the data base.
2.Connect to the console or another station (data base
programmable).
STEPOPERATIONRESULT
1
2
NOTES:
1.
2.
3
4
5
6
5210
Enter Request for Wake-UpDepress WAKE-UP button.(a) WAKE-UP LED on.
(b) KEDU display fields off.
(c) ROOM NUMBER LED on.
(d) HOUR-MINUTE LED on.
Enter room number.(a) Room number displayed in ROOM
NUMBER display field.
(b) FFFF...

Page 296

TL-I 30100-l 001STEPOPERATIONRESULT(c) ROOM NUMBER LED on.
(d) HOUR-MINUTE LED on.
7Enter room number.(a) Room number is displayed in the
ROOM NUMBER field.
(b) Data previously entered (wake-up
time) shown on display field.
(c) ROOM NUMBER LED on.
(d) HOUR-MINUTE LED on.
(e) Response code field displays “A”.
8Depress CLEAR button.HOUR-MINUTE field off.
9Depress ENTER/XCUTE button.(a) HOUR-MINUTE field displays FFFF.
(b) The response code field displays “A”.
(c) If printer is provided, see Table 9.1
for...

Page 297

TL-130100-1001STEPOPERATIONRESULT
4Depress ENTEFVXCUTE button.
5The next function performed clears
the KEDU.
Cancel Message Waiting
6Depress MESG WTG button.
7Enter room number. (If room
number is three digits, enter
a # after the third digit.)
8
9Depress CLEAR button.DATA and response code display fields off.
Depress ENTEFVXCUTE button.
10The next function performed clears
the KEDU.
NOTE:When the room occupant responds to the message-waiting indication using the
message center access code, the flashing...

Page 298

TL-130100-1001
STEPOPERATIONRESULT
1Depress MESG METER button.
2Enter room number. (Must be 4 digits. (a) Room number is displayed in the
If 3 digits, enter a # after the thirdROOM NUMBER field.
digit.)(b) DATA field displays the meter count
(if any).
3The next function performed clears
the KEDU.
Entering New Count in Message Meter
4Depress MESG METER button.
5Enter room number.
6Depress ENTER/XCUTE button.
7
8Enter meter count (000 to 255).DATA field displays the meter count.
Depress 
ENTER/XCUTE...

Page 299

TL-130100-1001
STEPOPERATIONRESULT11Enter room number.(a) Room number is displayed in the
NUMBER field.
(b) DATA field displays the meter count.
(c) Response code field displays “A”.
12Depress CLEAR button.(a) DATA field off.
(b) Response code “A” off.
13Depress ENTER/XCUTE button.(a) DATA field displays “A”.
(b) The response code field displays “A”.
(c) If printer is provided, see Table 9.1 for
typical printer displays.
14The next function performed clears
the KEDU.
9.4.6Audit Requests
An audit may be...

Page 300

TL-130100-1001STEPOPERATIONRESULT
3Enter *** 1.
4(c) Printer will print the appropriate title
and column heading followed by data.
Abort Audit Request(a) ROOM NUMBER field displays 
‘IEEE1 ‘I.(b) Response code field displays one of the
following:
1. If the audit is stopped, “A” is
displayed.
2. If the abort audit function is denied,
“D” is displayed.
3. If the audit is not in progress, 
“F” is
displayed.
Message Meter Audit with Memory ClearEnter 
* * * 2.(a) ROOM NUMBER field displays “EEE2”.(b)...